A Symmetrical-Asymmetrical Fault Characteristics Analysis within Cogeneration Power Plant in Izmir, Turkey: An Experimental Assessment

Pages
524–540
Publication Date
2022-11-08
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Considering the prices of protection equipment, which has a large part in system design, this way would allow designer to reduce the cost of the protective equipment and remaining stability.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The analysis of the short circuit should be understood very well in order to make correct designs in the power systems such as the safety of the personnel and the equipment, the selection of the safety relays, the circuit breaker selection and the selection of the appropriate conductor section.
📊
Key Findings & Data:The real short circuit fault results measured from the power plant and the grid and the results obtained from the software program have been compared and it has been determined that there is not a significant difference between them.
💡
Conclusion & Impact:Considering the prices of protection equipment, which has a large part in system design, this way would allow designer to reduce the cost of the protective equipment and remaining stability.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Fault calculation · Power systems analysis · Short circuit

Abstract

The analysis of the short circuit should be understood very well in order to make correct designs in the power systems such as the safety of the personnel and the equipment, the selection of the safety relays, the circuit breaker selection and the selection of the appropriate conductor section. In this study, the parameters about the short circuit and the techniques of calculating the faults in system and the necessary theoretical knowledge for the short circuit fault to be understood better have been given. The effect on the distributed generation and the grid which is caused by the possible short circuit faults have been simulated by being modeled in PSS/Sincal and by using the real grid parameters with cogeneration power plant in Izmir, Turkey. The real short circuit fault results measured from the power plant and the grid and the results obtained from the software program have been compared and it has been determined that there is not a significant difference between them. Thus, it has been emphasized that it is correct to simulate before investing in a power system in for the purpose of restrain the faults during the designing and working before the application. It allows the designer to design new power plant as good as plan expansion of existing power plants with higher degree of precision. Considering the prices of protection equipment, which has a large part in system design, this way would allow designer to reduce the cost of the protective equipment and remaining stability.

🔖

Cite This Article

ÖZTURA, H. Ş., POLAT, S. (2022). A Symmetrical-Asymmetrical Fault Characteristics Analysis within Cogeneration Power Plant in Izmir, Turkey: An Experimental Assessment. Gazi University Journal of Science, Cilt: 35 - Sayı: 2, 524–540. https://ajindex.com/articles/650870

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Das, T., Roy, R. and Mandal, K.K., “Impact of the penetration of distributed generation on optimal reactive power dispatch”, Protection and Control of Modern Power Systems, 5 (1): (2020)
  2. Guo, J., Ding, X. and Wu, W., “A Blockchain-Enabled Ecosystem for Distributed Electricity Trading in Smart City”, IEEE Internet of Things Journal, 8 (3): 2040–2050, (2021)
  3. Baloch, S. and Muhammad, M.S., “An Intelligent Data Mining-Based Fault Detection and Classification Strategy for Microgrid”, IEEE Access, 9 22470–22479, (2021)
  4. Pesaran H.A.M., Huy, P.D. and Ramachandaramurthy, V.K., “A review of the optimal allocation of distributed generation: Objectives, constraints, methods, and algorithms”, Renewable and Sustainable Energy Reviews, 75 (May 2016): 293–312, (2017)
  5. Haider, W., S.J. Ul Hassan, A. Mehdi, A. Hussain, G.O.M. Adjayeng, and C.H. Kim, “Voltage profile enhancement and loss minimization using optimal placement and sizing of distributed generation in reconfigured network”, Machines, 9 (1): 1–16, (2021)
  6. Karimi, M., Farshad, M., Hong, Q., Laaksonen, H. and Kauhaniemi, K., “An Islanding Detection Technique for Inverter-Based Distributed Generation in Microgrids”, Energies, 14 (1): 130, (2020)
  7. Zheng, T., Yang, H., Zhao, R., Kang, Y.C. and Terzija, V., “Design, evaluation and implementation of an islanding detection method for a micro-grid”, Energies, 11 (2): 323, (2018)
  8. Pinto, J.O.C.P. and Moreto, M. “Protection strategy for fault detection in inverter-dominated low voltage AC microgrid”, Electric Power Systems Research, 190 (August 2020): 106572, (2021)
  9. Kim, I., “A calculation method for the short-circuit current contribution of current-control inverter-based distributed generation sources at balanced conditions”, Electric Power Systems Research, 190 (August 2020): 106839, (2021)
  10. Xiao, H., Ren, S. and Li, Y., “Novel disturbance blocking criterion for reliable current differential protection of LCC-HVDC lines”, IEEE Transactions on Power Delivery, 36 (1): 477–480, (2021)
  11. Gao, S.P., Liu, Q. and Song, G.B., “Current differential protection principle of HVDC transmission system”, IET Generation, Transmission and Distribution, 11 (5): 1286–1292, (2017)
  12. Zarei, S.F. and Khankalantary, S., “Protection of active distribution networks with conventional and inverter-based distributed generators”, International Journal of Electrical Power and Energy Systems, 129 (June 2020): 106746, (2021)
  13. Sahito, A