Journals / Eurasian Journal of Emergency Medicine / 2020 / Cilt: 19 - Sayı: 2

Thoracic Fluid Content Measurement: Diagnostic Value of Suspected Pulmonary Oedema in Acute Decompensate Heart Failure

Pages
63–70
Publication Date
2022-11-06
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Among these, only TFC was statistically significant in the diagnosis of PO (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: One of the non-invasive methods of monitoring changes in cardiovascular haemodynamics is the measurement of transthoracic impedance (TTI).
📊
Key Findings & Data:The most important features of this method are that it does not require catheterisation, it carries no risk of complications and it is both cost-effective and easily applicable.The aim of this study was to determine the diagnostic value of thoracic fluid content (TFC), which is one the parameters obtained from TTI measurement in patients who present to the emergency department (ED) with dyspnoea and are suspected of pulmonary oedema (PO) due to acute decompensate heart failure (ADHF).Materials and Methods: This single-centre, prospective, cohort clinical study was conducted on patients aged >18 years who presented to the tertiary care university ED with acute dyspnoea and were suspected of PO due to ADHF.
💡
Conclusion & Impact:Among these, only TFC was statistically significant in the diagnosis of PO (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: One of the non-invasive methods of monitoring changes in cardiovascular haemodynamics is the measurement of transthoracic impedance (TTI). The most important features of this method are that it does not require catheterisation, it carries no risk of complications and it is both cost-effective and easily applicable.The aim of this study was to determine the diagnostic value of thoracic fluid content (TFC), which is one the parameters obtained from TTI measurement in patients who present to the emergency department (ED) with dyspnoea and are suspected of pulmonary oedema (PO) due to acute decompensate heart failure (ADHF).Materials and Methods: This single-centre, prospective, cohort clinical study was conducted on patients aged >18 years who presented to the tertiary care university ED with acute dyspnoea and were suspected of PO due to ADHF. The primary outcome measure was to determine the diagnostic value of TFC measurement in patients who presented to the ED with dyspnoea and were suspected of PO due to ADHF.Results: A total of 113 patients were included in the study. The Brain Natriuretic Peptide (BNP) value was accepted as the gold standard in the diagnosis of PO due to ADHF. The sensitivity/specificity of PO associated with ADHF was 64.3/31.4%, 14.3/88.4% and 60.5/83.7% for TFC, cardiac index (CI) and stroke index, respectively. Among these, only TFC was statistically significant in the diagnosis of PO (p

🔖

Cite This Article

AVCI, A., KORKUT, M., BEKTAŞ, A. F., SÖYÜNCÜ, S. (2022). Thoracic Fluid Content Measurement: Diagnostic Value of Suspected Pulmonary Oedema in Acute Decompensate Heart Failure. Eurasian Journal of Emergency Medicine, Cilt: 19 - Sayı: 2, 63–70. https://ajindex.com/articles/650363

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Pang PS, Collins SP, Sauser K, Andrei A-C, Storrow AB, Hollander JE, et al. Assessment of Dyspnea Early in Acute Heart Failure: Patient Characteristics and Response Differences Between Likert and Visual Analog Scales. Hiestand B, editor. Acad Emerg Med. 2014;21:659-66
  2. Ponikowski P, Voors AA, Anker SD, Bueno H, Cleland JGF, Coats AJS, et al. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) Developed with the special contribution o. Eur Heart J. 2016;37:2129-200
  3. Collins SP, Storrow AB. Acute Heart Failure. In: Tintinalli Stapczynski JS, Ma OJ, Yealy DM, Meckler GD CD. Tintinalli’s Emergency Medicine: A Comprehensive Study Guide, 8e | AccessMedicine | McGraw-Hill Medical.
  4. Becker K. Resolved: A pulmonary artery catheter should be used in the management of the critically ill patient. Con. J Cardiothorac Vasc Anesth. 1998;12(2 Suppl 1):13-6
  5. Hendrickson K. Cost-effectiveness of noninvasive hemodynamic monitoring. AACN Clin Issues. 1999;10:419-24
  6. Sadauskas S, Naudžiūnas A, Unikauskas A, Mašanauskienė E, Bakšytė G, Macas A. Applicability of Impedance Cardiography During Heart Failure Flare-Ups. Med Sci Monit. 2016;;22:3614-22
  7. Summers RL, Shoemaker WC, Peacock WF, Ander DS, Coleman TG. Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography. Acad Emerg Med. 2003;10:669-80
  8. Pranulis MF. Impedance cardiography (ICG) noninvasive hemodynamic monitoring provides an opportunity to deliver cost effective, quality care for patients with cardiovascular disorders. J Cardiovasc Manag. 2000;11:13-7
  9. Peacock WF. The B-type natriuretic peptide assay: a rapid test for heart failure. Cleve Clin J Med. 2002;69:243-51
  10. Shah MR, Stinnett SS, McNulty SE, Gheorghiade M, Zannad F, Uretsky B, et al. Hemodynamics as surrogate end points for survival in advanced heart failure: An analysis from FIRST. Am Heart J. 2001;141:908-14
  11. Castellanos LR, Bhalla V, Isakson S, Daniels LB, Bhalla MA, Lin JP, et al. B-Type Natriuretic Peptide and Impedance Cardiography at the Time of Routine Echocardiography Predict Subsequent Heart Failure Events. J Card Fail. 2009;15:41-7
  12. Bhalla V, Isakson S, Bhalla M, Lin J, Clopton P, Gardetto N, et al