Journals / Ulusal Travma ve Acil Cerrahi Dergisi / 2018 / Cilt: 24 - Sayı: 4

Multislice computed tomographic measurements of optic nerve sheath diameter in brain injury patients

Beyin hasarı olan hastalarda çok kesitli bilgisayarlı tomografide optik sinir kılıfı ölçümleri

Pages
316–320
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The area under thereceiver operating characteristic curve was 0.600 (95% confidence interval, 0.508–0.692; p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:BACKGROUND: Currently, the measurement of optic nerve sheath diameter (ONSD) has been offered as a possible indicator ofintracranial pressure (ICP).
📊
Key Findings & Data:Increased ICP is observed during intracranial injury.
💡
Conclusion & Impact:The area under thereceiver operating characteristic curve was 0.600 (95% confidence interval, 0.508–0.692; p
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

BACKGROUND: Currently, the measurement of optic nerve sheath diameter (ONSD) has been offered as a possible indicator ofintracranial pressure (ICP). Increased ICP is observed during intracranial injury. The objective of this study was to evaluate the relationshipbetween increased ONSD and positive intracranial findings from multislice computed tomography (CT) of the brain.METHODS: In total, CT scans of 161 patients were retrospectively reviewed. The image that showed the largest ONSD was magnifiedfive times.RESULTS: The CT scan revealed intracranial lesions in 54 patients and no intracranial lesions in 107 patients. A significant relationshipwas observed between positive CT findings and increased ONSD: 5.60±0.75 mm vs. 5.35±0.75 mm (p=0.038). The area under thereceiver operating characteristic curve was 0.600 (95% confidence interval, 0.508–0.692; p

Özet

AMAÇ: Günümüzde, kafa içi basıncın (KİB) belirlenmesinde, optik sinir kılıfı çapı (OSKÇ) ölçümlerinden faydalanılabileceği belirtilmektedir. KİB artışı, intrakraniyal yaralanmaların doğal bir sonucudur. Bu çalışmada, çok kesitli bilgisayarlı beyin tomografisindeki, pozitif intrakraniyal bulgular ve OSKÇ genişlemesi arasındaki ilişki değerlendirildi. GEREÇ VE YÖNTEM: Toplam 161 hastanın çok kesitli BT görüntüleri geriye dönük incelendi. Ölçümler, kesitlerde optik sinirin en geniş görüldüğü bölge beş kez büyütülerek yapıldı. BULGULAR: Çok kesitli beyin tomografisi görüntülerinde, 54 hastada kafa içi hasar tespit edilirken, 107 hastada edilmedi. Pozitif tomografi bulguları ile OSKÇ artışı arasında anlamlı ilişki olduğu belirlendi, 5.60±0.75 mm ve 5.35±0.75 mm (p=0.038). ROC eğrisinin altında kalan alan, 0.600 (%95 güven aralığında 0.508–0.692; p

🔖

Cite This Article

DÜZGÜN, F., BİLGE, A., GÖLCÜK, Y., İRİK, M., ÖZSARAÇ, M., YILMAZ, H., PABUŞCU, Y. (2022). Multislice computed tomographic measurements of optic nerve sheath diameter in brain injury patients. Ulusal Travma ve Acil Cerrahi Dergisi, Cilt: 24 - Sayı: 4, 316–320. https://ajindex.com/articles/644339

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Stein DM, Hu PF, Brenner M, Sheth KN, Liu KH, Xiong W, et al. Brief episodes of intracranial hypertension and cerebral hypoperfusionare associated with poor functional outcome after severe traumaticbrain injury. J Trauma 2011;71:364–73; discussion 373–4. [CrossRef ] Treggiari MM, Schutz N, Yanez ND, Romand JA. Role of intracranial pressure values and patterns in predicting outcome in traumatic brain injury: a systematic review. Neurocrit Care. 2007;6:104–12. [CrossRef ] Münch EC, Bauhuf C, Horn P, Roth HR, Schmiedek P, Vajkoczy P. Therapy of malignant intracranial hypertension by controlled lumbar cerebrospinal fluid drainage. Crit Care Med 2001;29:976–81. [CrossRef ] Rangel-Castilla L, Gopinath S, Robertson CS. Management of intracranial hypertension. Neurol Clin 2008;26:521–41. [CrossRef ] Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med 2008;15:201–4. [CrossRef ] Chen H, Ding GS, Zhao YC, Yu RG, Zhou JX. Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults. BMC Neurol 2015;15:106. [CrossRef ] Geeraerts T, Newcombe VF, Coles JP, Abate MG, Perkes IE, Hutchinson PJ, et al. Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure. Crit Care 2008;12:R114. [CrossRef ] Kimberly HH, Noble VE. Using MRI of the optic nerve sheath to detect elevated intracranial pressure. Crit Care 2008;12:181. [CrossRef ] Kalantari H, Jaiswal R, Bruck I, Matari H, Ghobadi F, Weedon J, et al. Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imaging. Am J Emerg Med 2013;31:1595–7. [CrossRef ] Killer HE, Laeng HR, Flammer J, Groscurth P. Architecture of arachnoid trabeculae, pillars, and septa in the subarachnoid space of the human optic nerve: anatomy and clinical considerations. Br J Ophthalmol 2003:777–81. [CrossRef ] Blaivas M, Theodoro D, Sierzenski PR. Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath. Acad Emerg Med 2003;10:376–81. [CrossRef ] Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T, Blaivas M. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med 2007;49:508–14. [CrossRef ] Frumin E, Schlang J, Wiechmann W, Hata S, Rosen S, Anderson C,