Journals / Uludağ Üniversitesi Mühendislik Fakültesi Dergisi / 2021 / Cilt: 26 - Sayı: 1

AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING

Bir Sanayi Yapısının Çevresel Titreşim Analizi

Pages
47–64
Publication Date
2022-11-06
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The velocities and accelerations causedby the sieve shaker system attached to the structure with springs, are evaluated under the effect of sampleloading.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Due to the heavy and dynamic equipment, the vibration and resonance effects that are notencountered under static dead loading may amplify over time in industrial buildings.
📊
Key Findings & Data:This might causedamage to the structural system and create human comfort problems while the structure is in service.
💡
Conclusion & Impact:The velocities and accelerations causedby the sieve shaker system attached to the structure with springs, are evaluated under the effect of sampleloading.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Due to the heavy and dynamic equipment, the vibration and resonance effects that are notencountered under static dead loading may amplify over time in industrial buildings. This might causedamage to the structural system and create human comfort problems while the structure is in service. In thisstudy, ambient vibration testing of a building composed of reinforced concrete and steel structural systemsand located at a boron processing plant in Turkey was performed. The velocities and accelerations causedby the sieve shaker system attached to the structure with springs, are evaluated under the effect of sampleloading.

Özet

Sanayi yapılarında ağır ve dinamik ekipmanlardan dolayı statik ve ölü yüklemelerde görülmeyecek ölçüde kesit tesirleri zaman içinde oluşabilmektedir. Bu durum yapıların hasar görmelerine ve kullanım sürecinde konfor sıkıntılarına neden olmaktadır. Bu çalışmada Türkiye’de bulunan bir bor işletmesi içindeki bir betonarme ve çelik taşıyıcı sisteme sahip bir binanın çevresel titreşim analizleri gerçekleştirilmiştir. Çalışmada yapının içinde bulunan ve yapıya yaylar ile bağlantılı olan dinamik elek sisteminden dolayı yapının betonarme ve çelik kolonlarında oluşan hız/ivme bileşenleri örnek yüklemeler etkisi altında değerlendirilerek yapının risk durumu incelenmiş ve gerekli önlemelerden bahsedilmiştir.

🔖

Cite This Article

DERE, Y., KARTAL, H., ARSLAN, M. H. (2022). AMBIENT VIBRATION ANALYSIS of an INDUSTRIAL BUILDING. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, Cilt: 26 - Sayı: 1, 47–64. https://ajindex.com/articles/643737

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Altunisik, A.C., Bayraktar, A. and Genc, A.F. (2015) Determination of the restoration effect on the structural behavior of masonry arch bridges, Smart Struct. Syst., 16(1), 101-139. DOI: 10.12989/sss.2015.16.1.101 2. Altunisik, A.C., Bayraktar, A., Sevim, B. and Birinci F. (2011) Vibration-based operational modal analysis of the Mikron historic arch bridge after restoration, Civil Eng. Environ. Syst., 28(3), 247-259. DOI: 10.1080/10286608.2011.588328 3. Aras, F. and Altay, G. (2015) Investigation of mechanical properties of masonry in historic buildings, Gradevinar, 67(5). DOI: 10.14256/JCE.1145.2014 4. Brincker, R., Ventura, C., and Andersen, P. (2003) Why ouput-only modal testing is a desirable tool for a wide range of practical applications, In 21st international Modal Analysis Conference (IMAC), Kissimmee, Florida. 5. DIN 4150 - 3 (1999)
  2. Vibrations in Buildings, Germany. 6. Ewins, D. J. (1995) Modal Testing: Theory and Practice, John Wiley & Sons, New York. ISBN: 978-0-863-80218-8 7. Michel, C., Gueguen, P. and Bard, P.Y. (2008) Dynamic parameters of structures extracted from ambient vibration measurements: An aid for the seismic vulnerability assessment of existing buildings in moderate seismic hazard regions, Soil Dynamics and Earthquake Engineering, 28, 593–604. DOI: 10.1016/j.soildyn.2007.10.002 8. Bayraktar, A., Temel, T., Altunışık, A. C., Sevim, B., Şahin, A. and Özcan, M. (2010) Binaların dinamik parametrelerinin operasyonal modal analiz yöntemiyle belirlenmesi, İMO Teknik Dergi, 5185-5205, Yazı 337. 9. Güneş, Ş. and Anıl Ö. (2017) Operasyonel model analiz tekniği ile yığma yapıların dinamik davranışının belirlenmesi, 4. Uluslararası Deprem Mühendisliği ve Sismoloji Konferansı – Anadolu Üniversitesi – Eskişehir. 10. Boru, E. O. and Kutanis M. (2015) Çevrel titreşim kayıtları kullanılarak yapı dinamik parametrelerinin belirlenmesi, SAÜ Fen. Bil. Der. 19. Cilt, 1. Sayı, S. 59-66. DOI: 10.16984/saufenbilder.77072 11. İnel, M., Özmen, H. B., Çaycı, B. T. and Özcan, G. (2013) Mevcut yapıların dinamik özelliklerinin mikrotremor ölçümleri ile belirlenmesi, 2. Türkiye Deprem Mühendisliği ve Sismoloji Konferansı – MKÜ – Hatay 12. Kusunokı, K., Hınata, D., Hattorı, Y. and Tasaı, A. (2018) A new method for evaluating the real-time residual seismic capacity of existing structures using accelerometers: Structures with multiple degrees of freedom, Japan Archit. Rev., Vol. 1, No. 1, 77–86. DOI: 10.1002/2475-8876.1010 13. Martakis, P., Reuland, Y., De