Challenges in Clinical Electrocardiography: Artifact or not?

Klinik Elektrokardiyografide Zorluklar: Artefakt mı Değil mi?

Pages
0
Publication Date
2013-01-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Take home messages: Electrocardiographic artifacts may cause unnecessary diagnosis and treatment

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A 53-year-old man was admitted to our hospital because of chest pain and palpitation.
📊
Key Findings & Data:Surface electrocardiography (ECG) taken on admission is shown in Figure 1 (also see all leads and arrows in V5).
💡
Conclusion & Impact:Take home messages: Electrocardiographic artifacts may cause unnecessary diagnosis and treatment
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Elektrokardiyografi · artefakt · preeksitasyon

Abstract

A 53-year-old man was admitted to our hospital because of chest pain and palpitation. The patient’s clinical history was unremarkable such as hypertension, diabetes mellitus or drug use. Physical examination was normal. Biochemical variables were within normal limits. Also, thyroid function tests and electrolytes were normal. Transthoracic echocardiography, Holter rhythm monitoring and electrophysiologic study revealed normal findings. Because of positive exercise test we performed coronary angiography which revealed normal coronary arteries. Surface electrocardiography (ECG) taken on admission is shown in Figure 1 (also see all leads and arrows in V5). Questions What is the most likely explanation for slurred QRS complexes and what rhythm abnormalities would you consider in the differential diagnosis? Comment Differential diagnosis comprises preexcitation, pseudodelta wave, blocked atrial premature beats and artifact. Electrocardiographic artifacts are typically unintentional and are not associated with hemodynamic findings(1). It may cause unnecessary diagnosis and treatment(1). They are usually caused by poor surface electrode contact or patient movement. In our case, the top tracing shows a burst of apparent wide complex tachycardia seen in leads I, II, aVr and aVL but not in lead III. Because of this, the most likely diagnoses is artifact. Thought it was the left arm but subsequently seen in aVL but not in lead II, so artifact may be variable depending on specific body movements. The bottom strip shows a constant sinus rhythm with erratic P wave activity, however the ventricular rate is constant. Note that some of the putative P waves fall very close to one another which would be unphysiological since the atrium needs a refractory period. Also note the erratic rhythm in lead II below. Take home messages: Electrocardiographic artifacts may cause unnecessary diagnosis and treatment

🔖

Cite This Article

Yıldız, M., Erdogan, O., Guler, A., Oner, C. N., Scheinman, M. M. (2013). Challenges in Clinical Electrocardiography: Artifact or not?. Koşuyolu Heart Journal, Cilt: 17 - Sayı: 1, 0. https://ajindex.com/articles/64026

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Pinter A, Sklar L, Dorian P. Factitious ventricular tachyarrhythmia outbreak. Arch Intern Med 2011;171:191-3. Figure 1. Surface electrocardiography on admission