Journals / Türk Onkoloji Dergisi / 2017 / Cilt: 32 - Sayı: 3

Total Scalp Irradiation: The Comparison of Five Different Plans Using Volumetric Modulated Arc Therapy- Simultaneous Integrated Boost (VMAT-SIB) Technique

Pages
106–115
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Plans 2, 3, 4, and 5 were inappropriate plans because the application of the virtual bolus in plan 2 was difficult, plan 3 with one isocenter was unacceptable with respect to the value of conformity index, plan 4 with three isocenters had a matching field, and plan 5 in which different priority values were used had an increase in OAR doses.CONCLUSIONVMAT-SIB can be preferred as an appropriate radiotherapy technique as it can provide optimum and allowable OAR doses in tumors requiring an intensive treatment planning effort.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of this study was to show that the optimum dosage can be delivered to the target organs at risk (OAR) by radiotherapy, which becomes more complicated because of technical difficulties arising from irregular, convex, and complex geometrical structure of the target, such as scalp irradiation, and because of situations resulting from the necessity of bolus of the lesion and immobilization as well as the proximity to neighboring critical organs using the VMAT-SIB technique.
📊
Key Findings & Data:These different VMAT scehemes were compared with respect to a dose volume histogram of obtained data, homogeneity, indices, conformity index, OAR, and doses of target volumes.RESULTSThe patient-designed bolus plan 1 with two isocenters was chosen as the most appropriate plan.
💡
Conclusion & Impact:Plans 2, 3, 4, and 5 were inappropriate plans because the application of the virtual bolus in plan 2 was difficult, plan 3 with one isocenter was unacceptable with respect to the value of conformity index, plan 4 with three isocenters had a matching field, and plan 5 in which different priority values were used had an increase in OAR doses.CONCLUSIONVMAT-SIB can be preferred as an appropriate radiotherapy technique as it can provide optimum and allowable OAR doses in tumors requiring an intensive treatment planning effort.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

The aim of this study was to show that the optimum dosage can be delivered to the target organs at risk (OAR) by radiotherapy, which becomes more complicated because of technical difficulties arising from irregular, convex, and complex geometrical structure of the target, such as scalp irradiation, and because of situations resulting from the necessity of bolus of the lesion and immobilization as well as the proximity to neighboring critical organs using the VMAT-SIB technique. METHODSFive different VMAT-SIB schemes were designed using the Varian Trilogy IX linear accelerator (Varian Medical Systems) for total scalp irradiation and bilateral neck irradiation. These different VMAT scehemes were compared with respect to a dose volume histogram of obtained data, homogeneity, indices, conformity index, OAR, and doses of target volumes.RESULTSThe patient-designed bolus plan 1 with two isocenters was chosen as the most appropriate plan. Plans 2, 3, 4, and 5 were inappropriate plans because the application of the virtual bolus in plan 2 was difficult, plan 3 with one isocenter was unacceptable with respect to the value of conformity index, plan 4 with three isocenters had a matching field, and plan 5 in which different priority values were used had an increase in OAR doses.CONCLUSIONVMAT-SIB can be preferred as an appropriate radiotherapy technique as it can provide optimum and allowable OAR doses in tumors requiring an intensive treatment planning effort.

🔖

Cite This Article

ÇINAR, Y., YILMAZ, S. R., EREN, M. (2022). Total Scalp Irradiation: The Comparison of Five Different Plans Using Volumetric Modulated Arc Therapy- Simultaneous Integrated Boost (VMAT-SIB) Technique. Türk Onkoloji Dergisi, Cilt: 32 - Sayı: 3, 106–115. https://ajindex.com/articles/639293

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Ito E, Nakamura M, Watanabe S and Morita A. Survival Analysis of Scalp Angiosarcoma Patients for Treatment Modalities in our Hospital Over the Past 28 Years. J Clin Exp Dermatol Res 2014;5(1):1-3
  2. Wanebo HJ, Koness RJ, MacFarlane JK, Eilber FR, Byers RM, Elias EG, et al. Head and neck sarcoma: report of the Head and Neck Sarcoma Registry. Society of Head and Neck Surgeons Committee on Research. Head Neck 1992;14(1):1-7
  3. Freedman AM, Reiman HM, Woods JE. Soft-tissue sarcomas of the head and neck. Am J Surg 1989;158(4):367- 72
  4. Espat NJ, Lewis JJ, Woodruff JM, Antonescu C, Xia J, Leung D, et al. Confirmed angiosarcoma: prognostic factors and outcome in 50 prospectively followed patients. Sarcoma 2000;4(4):173-7
  5. Bardwil JM, Mocega EE, Butler JJ, Russin DJ. Angiosarcomas of the head and neck region. Am J Surg 1968;116(4):548-53
  6. Rice S, Kozak KR and Mohindra P. Scalp angiosarcoma: Discussion of a management plan. Applied Radiation Oncology 2013:20-3
  7. Albores-Saavedra J, Schwartz AM, Henson DE, Kostun L, Hart A, Angeles-Albores D, et al. Cutaneous angiosarcoma. Analysis of 434 cases from the Surveillance, Epidemiology, and End Results Program, 1973-2007. Ann Diagn Pathol 2011;15(2):93-7
  8. ICRU Report 50. Prescribing, recording, and reporting photon beam therapy. Bethesda; 1993
  9. ICRU Report 62. Prescribing, recording and reporting photon beam therapy (supplement to ICRU report 50).Bethesda; 1999. 10.Hu J, Xiao W, He Z, Kang D, Chen A, Qi Z. Target splitting non-coplanar RapidArc radiation therapy for a diffuse sebaceous carcinoma of the scalp: a novel delivery technique. Radiat Oncol 2014;9:204. 11.Kelly PJ, Mannarino E, Lewis JH, Baldini EH, Hacker FL. Total dural irradiation: RapidArc versus static-field IMRT: a case study. Med Dosim 2012;37(2):175-81
  10. Feuvret L, Noël G, Mazeron JJ, Bey P. Conformity index: a review. Int J Radiat Oncol Biol Phys 2006;64(2):333-42
  11. Lomax NJ, Scheib SG. Quantifying the degree of conformity in radiosurgery treatment planning. Int J Radiat Oncol Biol Phys 2003;55(5):1409-19. 14.Onay Ö, Ünal Karabey A, Morgül Y, Karabey MS. A comparative planning study of step -and -shoot IMRT versus helical tomotherapy IMRT in the treatment of craniospinal tumor. Turk J Oncol 2014;29(2):46-52. 15.Nutting CM, Convery DJ, Cosgrove VP, Rowbottom C, Padhani AR, Webb S, et al. Reduction of small and large bowel irradiation using an optimized intensitymodulated pelvic radiotherapy technique in patients with prostate ca