Journals / Turkish Journal of Veterinary and Animal Sciences / 2016 / Cilt: 40 - Sayı: 2

The treatment of distal metacarpus fracture with locking compression plate in calves

Pages
234–242
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In conclusion, as the characteristics of juvenile bones do not provide sufficient physical strength for implants, we decided that locking compression plates are associated with good prognosis for surgical repair of distal metacarpal fractures in newborn calves.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, we aimed to evaluate the effect of locking compression plates for the treatment of distal metacarpal fractures in calves.
📊
Key Findings & Data:The calves started weight-bearing partially after the first postoperative day and resumed complete weight-bearing after day 10.
💡
Conclusion & Impact:In conclusion, as the characteristics of juvenile bones do not provide sufficient physical strength for implants, we decided that locking compression plates are associated with good prognosis for surgical repair of distal metacarpal fractures in newborn calves.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, we aimed to evaluate the effect of locking compression plates for the treatment of distal metacarpal fractures in calves. The metacarpus was stabilized using a stainless steel locking compression plate with fully threaded locking head screws. The calves started weight-bearing partially after the first postoperative day and resumed complete weight-bearing after day 10. Callus formation was obtained at the end of the 3rd week and completed at the end of the 8th week, and complete healing was seen at the 12th week in radiographs. The limbs were in good alignment, the calves were fully weight-bearing, and client satisfaction was very high. The metacarpal length, diameter of cortex, and diameter of medulla were measured in fractured and nonfractured metacarpi at the 1st, 45th, 120th, and 365th postoperative days. In conclusion, as the characteristics of juvenile bones do not provide sufficient physical strength for implants, we decided that locking compression plates are associated with good prognosis for surgical repair of distal metacarpal fractures in newborn calves.

🔖

Cite This Article

AKIN, İ., GÜLAYDIN, A., BELGE, A., YAZICI, M. F. (2022). The treatment of distal metacarpus fracture with locking compression plate in calves. Turkish Journal of Veterinary and Animal Sciences, Cilt: 40 - Sayı: 2, 234–242. https://ajindex.com/articles/615287

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Tulleners EP. Metacarpal and metatarsal fractures in dairy cattle: 33 cases (1979-1985). J Am Vet Med Assoc 1986; 189: 463–468
  2. Ferguson JG. Management and repair of bovine fractures. Comp Con Edu Pract Vet 1982; 4: 128–136
  3. Köstlin RG, Nuss K, Elma E. Metacarpal and metatarsal fractures in cattle: treatment and results. Tierarztl Prax 1990; 18: 131–144
  4. Görgül OS, Seyrek-İntaş D, Çelimli N, Çeçen G, Salcı H, Akın İ. Buzağılarda kırık olgularının değerlendirilmesi: 31 olgu (1996-2003). Vet Cer Derg 2004; 10: 16–20 (in Turkish)
  5. Firet O. Kliniğimize getirilen buzağılarda karşılaştığımız kırık olguları ve sağaltım olanakları. MSc, Adnan Menderes University, Aydın, Turkey, 2008 (in Turkish)
  6. Elma E. Frakturen beim rind. Behandlung und Ergebnisse in den Jahren 1970–1987. Dissertation, Veterinärmedizinische Universität, Munich, Germany, 1988 (in German)
  7. Aithal HP, Amarpal P, Pawde AM, Singh GR, Hoque M. Management of fractures near the carpal joint of two calves by trans articular fixation with a circular external fixator. Vet Rec 2007; 161: 193–198
  8. Turner AS. Large animal orthopedics. In: Jennings PB, editor. Practice of Large Animal Surgery. 1st ed. Philadelphia, PA, USA: Saunders; 1984. pp. 816–825
  9. Vachon A, De Bowes R. Internal fixation of a proximal metatarsal fracture in a calf. J Am Vet Med Assoc 1987; 191: 1465–1467
  10. Martens A, Steenhaut M, Gasthuys F, De Cupere C, De Moor A, Verschooten F. Conservative and surgical treatment of tibial fractures in cattle. Vet Rec 1998; 143: 12–16
  11. Prabhakar V, Raghunath M, Singh SS, Mohindroo J, Singh T, Verma P. Clinical management of metacarpal and metatarsal fractures in two buffalo-calves. Intas Polivet 2012; 13: 395–398
  12. Arıcan M, Esin E, Erol H. Evaluation of calves with fracture and result of intramedullary pinning: 72 cases. In: Proceedings of the 25th World Buiatrics Congress. Budapest, Hungary: WBC; 2008. pp. 255–256
  13. Aksoy Ö, Özaydın İ,Kılıç E Öztürk S, Güngör E, Kurt B, Oral H. Evaluation of fractures in calves due to forced extraction during dystocia: 27 cases (2003-2008). Kafkas Üniv Vet Fak Derg 2009;15: 339–344
  14. Steiner A. Management of metacarpal, metatarsal, radial and tibial fractures in calves. In: Proceedings of the 9th Annual European Society of Veterinary Orthopaedics and Traumatology Congress. Munich, Germany: ESVOT; 1998. pp. 95–96
  15. Auer JA, Watkins JP. Treatment of radial fractures in adult horses: an analysis of 15 clinical cases. Equine V