⚡ TL;DR(Too Long; Didn't Read)

Complete healing and return to function with no complications was recorded in all the cases.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Femoral fractures in cats are treated using pin and wires, lag screws, Rush pins, intramedullary threaded pins, interlockingpins, clamp rod internal fixators, and plates or plate-rods.
📊
Key Findings & Data:In this study, 14 cats brought to the surgery clinic between the years 2010and 2015 for fracture, due to either a road traffic accident or falling from a height, were evaluated.
💡
Conclusion & Impact:Complete healing and return to function with no complications was recorded in all the cases.
🔬Design:Research Article
📍Scope:2015 Verileri
⚙️Variables:Domain Parameters

Abstract

Femoral fractures in cats are treated using pin and wires, lag screws, Rush pins, intramedullary threaded pins, interlockingpins, clamp rod internal fixators, and plates or plate-rods. In this study, 14 cats brought to the surgery clinic between the years 2010and 2015 for fracture, due to either a road traffic accident or falling from a height, were evaluated. Following clinical and radiologicalexamination of the cases, the type and location of the fracture, details of the applied fixation method, and postoperative clinical andradiological results were assessed. Localization of the fractures was as follows: 4 comminuted diaphyseal (1 segmental), 6 comminuteddistal, and 4 uncomplicated distal transversal fractures. All fractures were closed. Following intramedullary positioning of the pins, rigidstabilization was observed in the fracture line. In the case of the segmental fracture, better stabilization was achieved when the medullarycanal was completely filled. The patients were able to use their extremities 3 5 days after surgery and started walking normally frompostoperative day 10. Functional healing was seen to improve gradually. Radiographic examination revealed sufficient calli to haveformed between days 32 and 44. Complete healing and return to function with no complications was recorded in all the cases.

🔖

Cite This Article

GÜZEL, Ö., KARABAĞLI, M., KAYA, D. A., ALTUNATMAZ, K., EKİCİ, H., ŞADALAK, D. J., UĞURLU, Ü., YALIN, E. E. (2022). The treatment of supracondylar and diaphyseal femoral fractures in cats using intramedullary two-way stacked Kirschner wire application. Turkish Journal of Veterinary and Animal Sciences, Cilt: 41 - Sayı: 2, 282–287. https://ajindex.com/articles/615000

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Whitehair JG, Vasseur PB. Fractures of the femur. Vet Clin North Am Small Anim Pract 1992; 2: 149-159
  2. Beale B. Orthopedic clinical techniques femur fracture repair. Clin Tech Small Anim Pract 2004; 19: 134-150
  3. Braden TD, Eicker SW, Abdinoor D, Prieur WD. Characteristics of 1000 femoral fractures in the dog and cat. Vet Comp Orthop Traumatol 1995; 8: 38-44
  4. Piermattei DL, Flo GL. Correction of abnormal bone growth and healing. In: Piermattei DL, Flo GL, DeCamp CE, editors. Brinker, Piermattei and Flo’s Handbook of Small Animal Orthopedics and Fracture Repair. 3rd ed. Philadelphia, PA, USA: WB Saunders Company; 1997. pp. 503-511
  5. Simpson DJ, Lewis DD. Fracture of the femur. In: Slatter D, editor. Textbook of Small Animal Surgery. 3rd ed. Philadelphia, PA, USA: WB Saunders Company; 2003. pp. 2059-2089
  6. Scotti S, Klein A, Pink J, Hidalgo A, Moissonnier P, Fayolle P. Retrograde placement of a novel 3.5 mm titanium interlocking nail for supracondylar and diaphyseal femoral fractures in cats. Vet Comp Orthop Traumatol 2007; 20: 211-218
  7. Chandler JC, Beale BS. Feline orthopedics. Clin Tech Small Anim Pract 2002; 17: 190-203
  8. Coetzee GL. Long bone fracture fixation with an intramedullary pin and C-clamp-on plate in dogs: 21 cases (1992-1997). Vet Comp Orthop Traumatol 1999; 12: 31-37
  9. Deyoung DJ, Probst CW. Methods of internal fracture fixation. In: Slatter DH, editor. Textbook of Small Animal Surgery. 2nd ed. Philadelphia, PA, USA: WB Saunders Company; 1993. pp. 1610-1627
  10. Zahn K, Matis U. The clamp rod internal fixator - application and results in 120 small animal fracture patients. Vet Comp Orthop Traumatol 2004; 17: 110-120
  11. Altunatmaz K, Ozsoy S, Mutlu Z, Devecioglu Y, Guzel O. Use of intramedullary fully-threaded pins in the fixation of feline and canine humeral, femoral and tibial fractures. Vet Comp Orthop Traumatol 2012; 25: 321-325
  12. Könning T, Maarschalkerweerd RJ, Endenburg N Theyse LFH. A comparison between fixation methods of femoral diaphyseal fractures in cats - a retrospective study. J Small Anim Pract 2013; 54: 248-252
  13. Ozsoy S. Fixation of femur, humerus and tibia in cats using intramedullary threaded Steinmann pins. Vet Rec 2004; 155: 152-153
  14. Denny HR, Butterworth SJ. A Guide to Canine and Feline Orthopaedic Surgery. 4th ed. Oxford, UK: Blackwell Science; 2000
  15. Johnson AL, Smith C, Schaeffer DJ. Fragment reconstruction and bone plate fixation versus bridging plate fixation for treating highly