Examining stance phases with the help of infrared optical sensors in horses

Pages
636–641
Publication Date
2022-11-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It is considered that this technique might be used in thediagnosis of lameness in horses in the future with the reference measurements that were created with these data obtained from healthyhorses.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The purpose of the present study was to examine the walking phases in horses using the OptoGait system, which works withoptical sensors.
📊
Key Findings & Data:In this pilot study, 52 healthy horses were used.
💡
Conclusion & Impact:It is considered that this technique might be used in thediagnosis of lameness in horses in the future with the reference measurements that were created with these data obtained from healthyhorses.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

The purpose of the present study was to examine the walking phases in horses using the OptoGait system, which works withoptical sensors. In this pilot study, 52 healthy horses were used. For each horse, an average of 45 steps were examined. The stance phase,swing phase, step distance, and walking speeds of the horses were recorded. The stance phase of each step was examined in a separatemanner in 3 steps: contact phase, foot flat, and propulsive phase. The contact phase and the propulsive phase of the forelimb and hindlimb were significantly different. The propulsive phase was significantly shorter in the forelimb compared to in the hind limb, and thecontact phase was significantly shorter in the hind limb. The fact that the propulsive phase of the European warmblood horses used inour study was longer than that of the British and Arabian horses was significant. It is considered that this technique might be used in thediagnosis of lameness in horses in the future with the reference measurements that were created with these data obtained from healthyhorses.

🔖

Cite This Article

GÜNDEMİR, O., AVANUS, K., ATEŞPARE, Z. D., ERDİKMEN, D. O. (2022). Examining stance phases with the help of infrared optical sensors in horses. Turkish Journal of Veterinary and Animal Sciences, Cilt: 43 - Sayı: 5, 636–641. https://ajindex.com/articles/614828

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Kanatlı U, Yetkin H, Songür M, Öztürk A, Bölükbaşı S. Yürüme analizinin ortopedik uygulamaları. TOTBD Dergisi 2006; 5 (1- 2): 54-59
  2. Yalçın S, Özaras N. Yürüme Analizi. 1st ed. İstanbul, Turkey: Avrupa Matbaacılık, 2001
  3. De Luca CJ, Adam A, Wotiz R, Gilmore LD, Nawab SH. Decomposition of surface EMG signals. Journal of Neurophysiology 2006; 96 (3): 1646-1657
  4. Cerrah AO, Ertan H, Soylu AR. Spor bilimlerinde elektromyografi kullanımı. Spormetre Beden Eğitimi ve Spor Bilimleri Dergisi 2010; 8 (2): 43-49
  5. Merlo A, Campanini I. Technical aspects of surface electromyography for clinicians. The Open Rehabilitation Journal 2010; 3: 98-109
  6. Besancon MF, Conzemius MG, Evans RB, Ritter MJ. Distribution of vertical forces in the pads of Greyhounds and Labrador Retrievers during walking. American Journal of Veterinary Research 2004; 65 (11): 1497-1501
  7. Bockstahler BA, Skalicky M, Peham C, Müller M, Lorinson D. Reliability of ground reaction forces measured on a treadmill system in healthy dogs. The Veterinary Journal 2007; 173 (2): 373-378
  8. DuLaney D, Purinton T, Dookwah H, Budsberg S. Effect of starting distance on vertical ground reaction forces in the normal dog. Veterinary and Comparative Orthopaedics and Traumatology 2005; 18 (3): 183-185
  9. Brown DC, Boston RC, Farrar JT. Comparison of force plate gait analysis and owner assessment of pain using the Canine Brief Pain Inventory in dogs with osteoarthritis. Journal of Veterinary Internal Medicine 2013; 27 (01): 22-30
  10. Kim J, Kazmierczak KA, Breur GJ. Comparison of temporospatial and kinetic variables of walking in small and large dogs on a pressure-sensing walkway. American Journal of Veterinary Research 2011; 72 (09): 1171-1177
  11. Lienhard, K, Schneider, D, Maffiuletti N. Validity of the Optogait photoelectric system for the assessment of spatiotemporal gait parameters. Medical Engineering and Physics 2013; 35 (4): 500-504
  12. McCracken, MJ, Kramer, J, Keegan, KG, Lopes M, Wilson DA et al. Comparison of an inertial sensor system of lameness quantification with subjective lameness evaluation. Equine Veterinary Journal 2012; 44: 652-656
  13. Keegan, KG. The Lameness Locator (wireless inertial sensors for detection of lameness in horses). In Proceedings of the Congress of the European Society of Veterinary Orthopaedics and Traumatology, Bologna, Italy; 2010; 15: 215-217