Journals / Turkish Journal of Urology / 2018 / Cilt: 44 - Sayı: 3

PI-RADS v2: Current standing and future outlook

PI-RADS v2: Güncel durum ve geleceğe bakış

Pages
189–194
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Overall, PI-RADSv2 shows improved sensitivity and similar specificity compared to PI-RADS v1.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The Prostate Imaging-Reporting and Data System (PI-RADS) was created in 2012 to establish standardizationin prostate multiparametric magnetic resonance imaging (mpMRI) acquisition, interpretation, andreporting.
📊
Key Findings & Data:In hopes of improving upon some of the PI-RADS v1 shortcomings, the PI-RADS Steering Committeereleased PI-RADS v2 in 2015.
💡
Conclusion & Impact:Overall, PI-RADSv2 shows improved sensitivity and similar specificity compared to PI-RADS v1.
🔬Design:Review & Systematic Survey
📍Scope:2012 Verileri
⚙️Variables:Domain Parameters

Abstract

The Prostate Imaging-Reporting and Data System (PI-RADS) was created in 2012 to establish standardizationin prostate multiparametric magnetic resonance imaging (mpMRI) acquisition, interpretation, andreporting. In hopes of improving upon some of the PI-RADS v1 shortcomings, the PI-RADS Steering Committeereleased PI-RADS v2 in 2015. This paper reviews the accuracy, interobserver agreement, and clinicaloutcomes of PI-RADS v2 and comments on the limitations of the current literature. Overall, PI-RADSv2 shows improved sensitivity and similar specificity compared to PI-RADS v1. However, concerns existregarding interobserver agreement and the heterogeneity of the study methodology.

Özet

PI-RADS, 2012 yılında prostat multiparametrik manyetik rezonans görüntüleme (mpMRG) görüntü elde edilmesi, değerlendirilmesi ve raporlanması işlemlerinin standardizasyonu amacıyla geliştirilmiştir. PIRAS v1 sınırlılıklarını giderme amacıyla 2015 yılında PI-RADS komitesi PI-RADS v2 dokümanını yayınlamıştır. Bu yazıda, PI-RADS v2'nin doğruluğu, gözlemciler arası uyumu ve klinik sonuçları gözden geçirilmiş ve mevcut literatürdeki sınırlılıklara değinilmiştir. Genellikle PI-RADS v2, PI-RADS v1’e göre iyileşmiş duyarlılık ve benzer özgüllük sergilemekle birlikte gözlemciler arasında uyum ve çalışma metodolojisinin heterojenisitesi konusunda kaygılar mevcuttur

🔖

Cite This Article

SMİTH, C. P., TÜRKBEY, B. (2022). PI-RADS v2: Current standing and future outlook. Turkish Journal of Urology, Cilt: 44 - Sayı: 3, 189–194. https://ajindex.com/articles/614386

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Haghighi M, Shah S, Taneja SS, Rosenkrantz AB. Prostate cancer: diffusion-weighted imaging versus dynamic-contrast enhanced imaging for tumor localization-a meta-analysis. J Comput Assist Tomogr 2013
  2. [CrossRef] Barentsz J, de Rooij M, Villeirs G, Weinreb J. Prostate Imaging- Reporting and Data System Version 2 and the Implementation of High-quality Prostate Magnetic Resonance Imaging. Eur Urol 2017
  3. [CrossRef] Esses SJ, Taneja SS, Rosenkrantz AB. Imaging Facilities’ Adherence to PI-RADS v2 Minimum Technical Standards for the Performance of Prostate MRI. Acad Radiol 2018
  4. [CrossRef] Greer MD, Shih JH, Barrett T, Bednarova S, Kabakus I, Law YM, et al. All over the map: An interobserver agreement study of tumor location based on the PI-RADSv2 sector map. J Magn Reson Imaging 2018: DOI: 10.1002/jmri.25948. [CrossRef] Weinreb JC, Barentsz JO, Choyke PL, Cornud F, Haider MA, Macura KJ, et al. PI-RADS Prostate Imaging - Reporting and Data System: 2015, Version 2. Eur Urol 2016
  5. [CrossRef] Biopsy: Prostate Imaging Reporting and Data System Version 2-based Diagnostic Performance for Detection of Prostate Cancer. Radiology 2017
  6. [CrossRef] Tan N, Lin WC, Khoshnoodi P, Asvadi NH, Yoshida J, Margolis DJ, et al. In-Bore 3-T MR-guided Transrectal Targeted Prostate Rosenkrantz AB, Babb JS, Taneja SS, Ream JM. Proposed Adjustments to PI-RADS Version 2 Decision Rules: Impact on Prostate Cancer Detection. Radiology 2017
  7. [CrossRef] Rosenkrantz AB, Oto A, Turkbey B, Westphalen AC. Prostate Imaging Reporting and Data System (PI-RADS), Version 2: A Critical Look. AJR Am J Roentgenol 2016
  8. [CrossRef] Tewes S, Mokov N, Hartung D, Schick V, Peters I, Schedl P, et al. Standardized Reporting of Prostate MRI: Comparison of the Prostate Imaging Reporting and Data System (PI-RADS) Version 1 and Version 2. PloS One 2016
  9. e0162879. Polanec S, Helbich TH, Bickel H, Pinker-Domenig K, Georg D, Shariat SF, et al. Head-to-head comparison of PI-RADS v2 and PI-RADS v1. Eur J Radiol 2016
  10. [CrossRef] Feng ZY, Wang L, Min XD, Wang SG, Wang GP, Cai J. Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2. Chin Med J (Engl) 2016
  11. [CrossRef] Auer T, Edlinger M, Bektic J, Nagele U, Herrmann T, Schäfer G, et al. Performance of PI-RADS version 1 versus version 2 re-garding the relation with histopathological results. W