In this paper we discuss the design criteria of all magnets of the TARLA injector and present design results.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The installation of a high current thermionic gun-based injector capable to accelerate a maximum 1.5 mA electron beam at 250 keV and continuous wave (CW) for various bunch repetition rates has been continuing at the Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) since 2014.
📊
Key Findings & Data:The injector, which is based on totally normal conducting technology, will mainly consist of a thermionic DC electron gun, two stage bunch compressor cavities operating at 260 MHz and 1.3 GHz, one dipole magnet, ve solenoid lenses and an additional one dipole magnet that is going to be used as spectrometer, and several steerer magnets.
💡
Conclusion & Impact:In this paper we discuss the design criteria of all magnets of the TARLA injector and present design results.
🔬Design:Experimental Field Trial
📍Scope:2014 Verileri
⚙️Variables:Domain Parameters

Abstract

The installation of a high current thermionic gun-based injector capable to accelerate a maximum 1.5 mA electron beam at 250 keV and continuous wave (CW) for various bunch repetition rates has been continuing at the Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) since 2014. The injector, which is based on totally normal conducting technology, will mainly consist of a thermionic DC electron gun, two stage bunch compressor cavities operating at 260 MHz and 1.3 GHz, one dipole magnet, ve solenoid lenses and an additional one dipole magnet that is going to be used as spectrometer, and several steerer magnets. In this paper we discuss the design criteria of all magnets of the TARLA injector and present design results.

🔖

Cite This Article

AKSOY, A. (2022). Design of Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility injector magnets. Turkish Journal of Physics, Cilt: 41 - Sayı: 2, 171–181. https://ajindex.com/articles/614017

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Aksoy, A.; Karsl,  O.; Yavas,  O. Infrared Phys. Techn. 2008, 51, 378-381
  2. Aksoy, A.; Karsl,  O. TARLA Design Report; Ankara University, Institute of Accelerator Technologies, Ankara, Turkey, 2015
  3. Aksoy, A.; Lehnert, U. Nucl. Instr. Meth. Phys. Res. A 2014, 762, 54-63
  4. Computer Simulation Technology,
  5. Floettmann, K. ASTRA User Manual; DESY, Hamburg, Germany, 2011
  6. Liebl, H. Applied Charged Particle Optics; Springer: Berlin, Germany, 2008
  7. Wiedemand, H. Particle Accelerator Physics; Springer: Berlin, Germany, 2007
  8. Brandt, D. In CAS-CERN Accelerator School Proceedings: Specialized Course on Magnets, Bruges, Belgium, 16{25 June 2009
  9. Nergiz, Z. Nucl. Instr. Meth. Phys. Res. A 2015, 795, 140-143
  10. Gabriel, F.; Gippner, P; Grosse, E.; Janssen, D.; Michel, P.; Prade, H.; Schamlott, A.; Seidel, W.; Wolf, A.; Wunsch, R. Nucl. Instr. Meth. Phys. Res. B 2000, 161-163, 1143-1147