Journals / Turkish Journal of Medical Sciences / 2005 / Cilt: 35 - Sayı: 3

Polarized Mueller Matrix Analytical Model for Glucose Measurement in Vitro

Pages
149–155
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results are in good agreement with those in the literature.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study we present a noninvasive and nonradioactive glucose in vitro measurement technique using the Mueller polarization analytical model.
📊
Key Findings & Data:The glucose solution and aqueous humor phantoms are illuminated with a He-Ne (632.8 nm) laser.
💡
Conclusion & Impact:The results are in good agreement with those in the literature.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Polarization · glucose sensor · birefringence

Abstract

In this study we present a noninvasive and nonradioactive glucose in vitro measurement technique using the Mueller polarization analytical model. The glucose solution and aqueous humor phantoms are illuminated with a He-Ne (632.8 nm) laser. This in vitro study provides a base and reference data for in vivo eye glucose monitoring. The 16 Mueller polarization matrix element images give information about eye absorption and scattering, and changes in polarization patterns to measure glucose concentration. The interior part of the eye (aqueous humor) contains a birefringent scattering medium for glucose measurement. The Mueller matrix polarimetric technique for simultaneous extraction of rotating linear and circular polarized light is discussed theoretically and experimentally implemented. This method requires calculation of the Mueller matrix for different orientations of polarized light through turbid samples. The results are in good agreement with those in the literature.

Özet

In this study we present a noninvasive and nonradioactive glucose in vitro measurement technique using the Mueller polarization analytical model. The glucose solution and aqueous humor phantoms are illuminated with a He-Ne (632.8 nm) laser. This in vitro study provides a base and reference data for in vivo eye glucose monitoring. The 16 Mueller polarization matrix element images give information about eye absorption and scattering, and changes in polarization patterns to measure glucose concentration. The interior part of the eye (aqueous humor) contains a birefringent scattering medium for glucose measurement. The Mueller matrix polarimetric technique for simultaneous extraction of rotating linear and circular polarized light is discussed theoretically and experimentally implemented. This method requires calculation of the Mueller matrix for different orientations of polarized light through turbid samples. The results are in good agreement with those in the literature.

🔖

Cite This Article

FIRDOUS, S., IKRAM, M. (2022). Polarized Mueller Matrix Analytical Model for Glucose Measurement in Vitro. Turkish Journal of Medical Sciences, Cilt: 35 - Sayı: 3, 149–155. https://ajindex.com/articles/611975

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Cotran RS, Kumarand V, Robbins SL. Robbins Pathologic Basis of Diseases, 4th ed., 994-1005,
  2. W. B. Saunders, Philadelphia 1989.
  3. Mollema ED, Snoek FJ, Ader HJ et al. Insulin-treated diabetes patients with fear of self-injecting or fear or self-testing: psychological comorbidity and general well-being. J Psychosom Res 51: 665-672, 2001. 7. Davidson MB. Diabetes Mellitus Diagnosis and Treatment, 3rd ed., 230-292,
  4. Churchill Livingstone, New York 1991.
  5. Bueno JM, Vargas-Martyn F. Measurements of the corneal birefringence with a liquid-crystal imaging polariscope, Appl Opt 41: 116-124, 2002.
  6. Flier IS, Underhill LH. Advanced glycosylation end products in tissue and the biochemical basis of diabetic complications, New England J. Med 318: 1315-1321, 1988.
  7. Ansari RR, Bockle S, Rovati L. New optical scheme for a polarimetric-based glucose sensor, Journal of Biomedical Optics 9: 103–115, 2004.
  8. Bockle S, Rovati L, Ansari RR. Polarimetric glucose sensing using the Brewster-reflection off the eye lens: theoretical analysis, Proc. SPIE 4624, 160–164, 2002.
  9. Cameron BD, Gorde HW, Satheesan B et al. The use of polarized laser light through the eye for noninvasive glucose monitoring, Diabetes Technol. Therap. 1: 135-143, 1999. Foster DW. Diabetes Mellitis. Harrison’s Principles of Internal Medicine, Wilson JD, Braunwald E, Eds., 1739-1758,
  10. McGraw- Hill, New York 1991.
  11. Cameron BD, Gorde HW, Coté GL. Development of an optical polarimeter system for in vivo glucose monitoring, Proc.SPIE 3599, 43–49, 1999.
  12. Pelizzari S, Rovati L, Angelis C. Rotating polarizer and rotating retarder plate polarimeters: comparison of performances, Proc. SPIE 4285, 235–243, 2001.
  13. McNichols RJ, Coté GL. Optical glucose sensing in biological fluids: an overview, J. Biomed. Opt 5: 5–16, 2000.
  14. Cameron BD, Coté GL. Noninvasive Glucose Sensing Utilizing a Digital Closed-Loop Polarimetric Approach, IEEE Transactions on Biomedical Engineering 44: 12: 1221–1227, 1997.
  15. Browne CA, Zerban FW. Physical and Chemical Methods of Sugar Analysis, New York, London: Chapman & Hill 1941. Driskill WT. Diabetes continues to be the nation’s fourth leading cause of death, Health Educator 12, 1996.
  16. Rabinovitch B, March WF, Adams RL. Nonivasive glucose monitoring of the aqueous humor of the eye. Part I. Measurement of very small optical rotations, Diabetes Care 5: 254-258, 1982.
  17. Knighton RW, Huang X. Linear birefringence of the central human cornea, Invest. Ophthalmol. Visual Sci 43: 82–86, 2002. Klonoff DC. Noninvasive blood glu