Journals / Turkish Journal of Medical Sciences / 2010 / Cilt: 40 - Sayı: 5

Dissection of mesoappendix in laparoscopic appendectomy: a comparison of monopolar cautery and bipolar vessel sealing system

Pages
757–760
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: In children, comparing to monopolar cautery, bipolar vessel sealer can be used effectively and safely in the dissection and hemostasis of appendiceal mesentery and is definitely an effective system in decreasing the operation time.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Various technique and different instruments like endoscopic stapler, endoscopic clip, monopolar cautery, harmonic scalpel, and bipolar vessel sealer can be used in the dissection of appendix mesentery when performing laparoscopic appendectomy.
📊
Key Findings & Data:Materials and methods: Sixty three patients, operated laparoscopically for acute appendicitis in between June 2008 and June 2009 at the Pediatric Surgery Clinic of Dışkapı Children's Hospital, are evaluated retrospectively.
💡
Conclusion & Impact:Conclusion: In children, comparing to monopolar cautery, bipolar vessel sealer can be used effectively and safely in the dissection and hemostasis of appendiceal mesentery and is definitely an effective system in decreasing the operation time.
🔬Design:Research Article
📍Scope:2008 Verileri
⚙️Variables:Key words: Monopolar cautery · vascular sealing system · laparoscopy

Abstract

Various technique and different instruments like endoscopic stapler, endoscopic clip, monopolar cautery, harmonic scalpel, and bipolar vessel sealer can be used in the dissection of appendix mesentery when performing laparoscopic appendectomy. The aim of this study is to evaluate the effects of using monopolar cautery and bipolar vascular sealing instruments in the dissection of mesentery of appendix on the duration of the operation of pediatric patients. Materials and methods: Sixty three patients, operated laparoscopically for acute appendicitis in between June 2008 and June 2009 at the Pediatric Surgery Clinic of Dışkapı Children's Hospital, are evaluated retrospectively. Monopolar cautery was used in 25 patients and bipolar vessel sealer was used in 38 patients. No intraoperative or postoperative complication was seen in any of the patients. None of the patients required conversion to open surgery due to dissection problems of the appendiceal mesentery. Results: The mean duration of operation was 51.08 min in the monopolar cautery group whereas 36, 68 minutes in the bipolar vessel sealing system group. Conclusion: In children, comparing to monopolar cautery, bipolar vessel sealer can be used effectively and safely in the dissection and hemostasis of appendiceal mesentery and is definitely an effective system in decreasing the operation time.

Özet

Various technique and different instruments like endoscopic stapler, endoscopic clip, monopolar cautery, harmonic scalpel, and bipolar vessel sealer can be used in the dissection of appendix mesentery when performing laparoscopic appendectomy. The aim of this study is to evaluate the effects of using monopolar cautery and bipolar vascular sealing instruments in the dissection of mesentery of appendix on the duration of the operation of pediatric patients. Materials and methods: Sixty three patients, operated laparoscopically for acute appendicitis in between June 2008 and June 2009 at the Pediatric Surgery Clinic of Dışkapı Children's Hospital, are evaluated retrospectively. Monopolar cautery was used in 25 patients and bipolar vessel sealer was used in 38 patients. No intraoperative or postoperative complication was seen in any of the patients. None of the patients required conversion to open surgery due to dissection problems of the appendiceal mesentery. Results: The mean duration of operation was 51.08 min in the monopolar cautery group whereas 36, 68 minutes in the bipolar vessel sealing system group. Conclusion: In children, comparing to monopolar cautery, bipolar vessel sealer can be used effectively and safely in the dissection and hemostasis of appendiceal mesentery and is definitely an effective system in decreasing the operation time.

🔖

Cite This Article

ŞENEL, E., TİRYAKİ, H. T., ATAYURT, H. F., AKBIYIK, F. (2022). Dissection of mesoappendix in laparoscopic appendectomy: a comparison of monopolar cautery and bipolar vessel sealing system. Turkish Journal of Medical Sciences, Cilt: 40 - Sayı: 5, 757–760. https://ajindex.com/articles/611524

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Takada M, Ichihara T, Kuroda Y: Non-clip laparoscopic colectomy using electrothermal bipolar vessel sealer clinical experiences. Hepatogastroenterology. 2006; 53: 840 -2. 9. Hubner M, Demartines N, Muller S, Dindo D, Clavien PA, Hahnloser D: Prospective randomized study of monopolar scissors, bipolar vessel sealer and ultrasonic shears in laparoscopic colorectal surgery. British J Surgery 2008; 95: 1098–1104.
  2. Lantis JC II, Durville FM, Connolly R, Schwaitzberg SD: Comparison of coagulation modalities in surgery. J Laparoendosc Adv Surg Tech A 1998; 8: 381– 94. Ata AH, Bellemore TJ, Meisel JA, Arambulo SM: Distal thermal injury from monopolar electrosurgery. Surg Laparosc Endosc 1993; 3: 323–7.
  3. Diamantis T, Kontos M, Arvelakis A, Syroukis S, Koronarchis D, Papalois A et al. Comparison of monopolar electrocoagulation, bipolar electrocoagulation, ultracision, and ligasure. Surg Today 2006; 36: 908–913.
  4. Landman J, Kerbl K, Rehman J, Andreoni C, Humphrey PA, Collyer W et al. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 2003; 169: 697-700.
  5. Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT: Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries Surg Endosc 2003; 17: 1228– 1230. Macario A, Dexter F, Sypal J, Cosgriff N, Heniford BT.: Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: a meta-analysis. Surg Innov. 2008; 15: 284-91.