Journals / Turkish Journal of Medical Sciences / 2017 / Cilt: 47 - Sayı: 5

Efficacy of bispectral index monitoring for prevention of anestheticawareness and complications during oocyte pick-up procedure

Pages
1583–1589
Publication Date
2022-11-03
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: During the OPU procedure BIS monitoring is considered to prevent anesthesia awareness, intraoperative movement, and complications caused by insufficient anesthetic use as it ensures optimal doses of anesthetic agents used and early recovery.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: This study was planned by considering that the use of bispectral index (BIS) monitoring ensures sufficient depth of anesthesia and avoids anesthetic awareness and patient movement in the oocyte pick-up (OPU) procedure.
📊
Key Findings & Data:Materials and methods: Ninety-eight patients undergoing OPU were randomly divided into 2 groups as the control group (n = 48) and BIS group (n = 50).
💡
Conclusion & Impact:Conclusion: During the OPU procedure BIS monitoring is considered to prevent anesthesia awareness, intraoperative movement, and complications caused by insufficient anesthetic use as it ensures optimal doses of anesthetic agents used and early recovery.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background/aim: This study was planned by considering that the use of bispectral index (BIS) monitoring ensures sufficient depth of anesthesia and avoids anesthetic awareness and patient movement in the oocyte pick-up (OPU) procedure. Materials and methods: Ninety-eight patients undergoing OPU were randomly divided into 2 groups as the control group (n = 48) and BIS group (n = 50). After propofol and remifentanil induction, the control group was given additional propofol according to reaction response, while the BIS group was given propofol at BIS values of 60 and above with the aim that BIS values be 40 60. Total procedure time, recovery time, patient movement, additional propofol consumption, total number of oocytes, and awareness during anesthesia were recorded. Results: Demographic data were similar in the two groups (P > 0.05 for all). The recovery time in the BIS group was significantly shorter compared to the control group (P < 0.001) while additional propofol consumption was found to be significantly lower (P < 0.001). Baseline BIS values fell compared to all other times after induction significantly (P < 0.001). No patient had anesthesia awareness. Conclusion: During the OPU procedure BIS monitoring is considered to prevent anesthesia awareness, intraoperative movement, and complications caused by insufficient anesthetic use as it ensures optimal doses of anesthetic agents used and early recovery.

🔖

Cite This Article

ARSLAN, M., BORAN, Ö. F., ÖKSÜZ, H., ÖKSÜZ, G., URFALIOĞLU, A., BAKACAK, M. (2022). Efficacy of bispectral index monitoring for prevention of anestheticawareness and complications during oocyte pick-up procedure. Turkish Journal of Medical Sciences, Cilt: 47 - Sayı: 5, 1583–1589. https://ajindex.com/articles/610551

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Vasudevan B, Borle A, Singh PM, Ramachandran R, Rewari V, Trikha A. The effect of anesthetic technique for transvaginal ultrasound-guided oocyte retrieval on reproductive outcomes: a systematic review and meta-analysis. J Obstet Anaesth Crit Care 2015; 5: 54-61
  2. Sharma A, Borle A, Trikha A. Anesthesia for in vitro fertilization. J Obstet Anaesth Crit Care 2015; 5: 62-72
  3. Circeo L, Grow D, Kashikar A, Gibson C. Prospective, observational study of the depth of anesthesia during oocyte retrieval using a total intravenous technique and the bispectral index monitor. Fertil Steril 2011; 96: 635-637
  4. Yasmin E, Dresner M, Balen A. Sedation and anaesthesia for transvaginal oocyte collection: an evaluation of practice in the UK. Hum Reprod 2004; 19: 2942-2945
  5. Vhalos NF, Giannakikou I, Vlachos, Vitoratos N. Analgesia and anesthesia for assisted reproductive technologies. Int J Gynaecol Obstet 2009; 105: 201-205
  6. Myles PS. Prevention of awareness during anaesthesia. Best Pract Res Clin Anaesthesiol 2007; 21: 345-355
  7. Zhang JM, Wang F, Xin Z, Zi TT, Lv H. Treatment of differentaged children under bispectral index monitoring with intravenous anesthesia with propofol and remifentanil. Eur Rev Med Pharmacol Sci 2015; 19: 64-69
  8. Gan TJ, Glass PS, Windsor A, Payne F, Rosow C, Sebel P, Manberg P. Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia. Anesthesiology 1997; 87: 808-815
  9. Ekman A, Lindholm ML, Lennmarken C, Sandin R. Reduction in the incidence of awareness using BIS monitoring. Acta Anaesthesiol Scand 2004; 48: 20-26
  10. Myles PS, Leslie K, McNeil J, Forbes A, Chan MTV. Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial. Lancet 2004; 363: 1757- 1763
  11. Ellerkmann RK, Kreuer S, Wilhelm W, Röpcke H, Hoeft A, Bruhn J. Reduction in anaesthetic drug consumption is correlated with mean titrated intra-operative bispectral index values. Acta Anaesthesiol Scand 2006; 50: 1244-1249
  12. Sinha PK, Koshy T. Monitoring devices for measuring the depth of anaesthesia - an overview. Indian J Anaesth 2007; 51: 365-381
  13. Edwards JA, Kinsella J, Shaw A, Evans S, Anderson KJ. Sedation for oocyte retrieval using target controlled infusion of propofol and incremental alfentanil delivered by non-anaesthetists. Anaesthesia 2010; 65: 453-461
  14. Handa-Tsutsui F, Kodaka M. Effect of nitrous oxide on propofol requirement du