Journals / Turkish Journal of Medical Sciences / 2018 / Cilt: 48 - Sayı: 1

Bedside measurement of the optic nerve sheath diameter with ultrasound in cerebrovascular disorders

Pages
93–99
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The specificity and sensitivity values were determined as 98.1% and81.8%, respectively, for a cutoff value of 5 mm and as 100% and 72.7%, respectively, for a cutoff value of 6 mm.Conclusion: This study showed that bedside measurement of ONSD is an easy, cheap, and noninvasive method that can be used tosupport the diagnosis and evaluation of patients with acute stroke.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: We aimed to show the role of determination of optic nerve sheath diameter (ONSD) by bedside ultrasonography inan emergency department in the diagnosis of cerebrovascular disorders and its correlation with the clinical picture.Materials and methods: This prospective cross-sectional study included 55 patients with cerebrovascular disorders and 53 controls.Age, sex, ONSD, comorbid disease status, and multidetector computed tomography results of all subjects and application periods andNational Institutes of Health Stroke Scale (NIHSS) scores of the patient group were evaluated.Results: The ONSD of the patient and control groups was determined as a median of 5.7 mm and 3.6 mm, respectively.
📊
Key Findings & Data:The ONSDof the patient group was determined to be significantly higher than that of the control group (P < 0.05).
💡
Conclusion & Impact:The specificity and sensitivity values were determined as 98.1% and81.8%, respectively, for a cutoff value of 5 mm and as 100% and 72.7%, respectively, for a cutoff value of 6 mm.Conclusion: This study showed that bedside measurement of ONSD is an easy, cheap, and noninvasive method that can be used tosupport the diagnosis and evaluation of patients with acute stroke.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background/aim: We aimed to show the role of determination of optic nerve sheath diameter (ONSD) by bedside ultrasonography inan emergency department in the diagnosis of cerebrovascular disorders and its correlation with the clinical picture.Materials and methods: This prospective cross-sectional study included 55 patients with cerebrovascular disorders and 53 controls.Age, sex, ONSD, comorbid disease status, and multidetector computed tomography results of all subjects and application periods andNational Institutes of Health Stroke Scale (NIHSS) scores of the patient group were evaluated.Results: The ONSD of the patient and control groups was determined as a median of 5.7 mm and 3.6 mm, respectively. The ONSDof the patient group was determined to be significantly higher than that of the control group (P < 0.05). A positive relationship wasdetermined between NIHSS scores and ONSD values (P < 0.05). The specificity and sensitivity values were determined as 98.1% and81.8%, respectively, for a cutoff value of 5 mm and as 100% and 72.7%, respectively, for a cutoff value of 6 mm.Conclusion: This study showed that bedside measurement of ONSD is an easy, cheap, and noninvasive method that can be used tosupport the diagnosis and evaluation of patients with acute stroke.

🔖

Cite This Article

AKÇAY, E., KAVAKLI, H. Ş., YÜZBAŞIOĞLU, S., YÜZBAŞIOĞLU, Y., COŞKUN, S., ÖZ, T., KUNT, R., BECEL, S., İÇME, F. (2022). Bedside measurement of the optic nerve sheath diameter with ultrasound in cerebrovascular disorders. Turkish Journal of Medical Sciences, Cilt: 48 - Sayı: 1, 93–99. https://ajindex.com/articles/610271

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Woloszyn AV, Schwarz MA. Early management of stroke patients in the emergency department. J Pharm Pract 2011; 24: 160-173.
  2. Go AS, Mozaffarian D, Roger VL, Benjamin EJ, Berry JD, Blaha MJ, Dai S, Ford ES, Fox CS, Franco S et al. Executive summary: heart disease and stroke statistics—2014 update: a report from the American Heart Association. Circulation 2014; 129: 399- 410. Go S, Worman DJ. Stroke syndromes. In: Tintinalli JE, editor. Emergency Medicine: A Comprehensive Study Guide. 8th ed. New York, NY, USA: McGraw-Hill; 2015. pp. 1142-1156.
  3. Speck V, Staykov D, Huttner HB, Sauer R, Schwab S, Bardutzky J. Lumbar catheter for monitoring of intracranial pressure in patients with post-hemorrhagic communicating hydrocephalus. Neurocrit Care 2011; 14: 208-215.
  4. Topcuoglu MA, Arsava EM, Das DF, Kozak HH. Transorbital ultrasonographic measurement of optic nerve sheath diameter in brain death. J Neuroimaging 2015; 25: 906-909.
  5. Lang EW, Paulat K, Witte C, Zolondz J, Mehdorn HM. Noninvasive intracranial compliance monitoring. Technical note and clinical results. J Neurosurg 2003; 98: 214-218.
  6. Dubourg J, Messerer M, Karakitsos D, Rajajee V, Antonsen E, Javouhey E, Cammarata A, Cotton M, Daniel RT, Denaro C et al. Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group. Syst Rev 2013; 2: 62. Sacco RL, Kasner SE, Broderick JP, Caplan LR, Connors JJ, Culebras A, Elkind MS, George MG, Hamdan AD, Higashida RT et al. An updated definition of stroke for the 21st century: a statement for healthcare professionals from the American Heart Association/American Stroke Association. Stroke 2013; 44: 2064-2089.
  7. Bellner J, Romner B, Reinstrup P, Kristiansson KA, Ryding E, Brandt L. Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP). Surg Neurol 2004; 62: 45-51.
  8. Saz-Saucedo P, Redondo-González O, Mateu-Mateu A, Huertas-Arroyo R, García-Ruiz R, Botia-Paniagua E. Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension. J Neurol Sci 2016; 361: 122-127.
  9. Goeres P, Zeiler FA, Unger B, Karakitsos D, Gillman LM. Ultrasound assessment of optic nerve sheath diameter in healthy volunteers. J Crit Care 2016; 31: 168-171.
  10. Geeraerts T, Launey Y, Martin L, Pottecher J, Vigué B, Duranteau J, Benhamou D. Ultrasonography of the optic nerve sheath may be useful for detecting rais