Journals / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 5

Comparison of 2-year clinical and radiological outcomes between volar plating and external fixation with additional K-wires for AO Type C distal radius fractures

Pages
1418–1425
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Function is not restored to the functionalityof the contralateral and noninjured hand.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: Surgical treatment of distal intraarticular radius fractures remains controversial.
📊
Key Findings & Data:Our aim was to compare the clinicaland radiological outcomes between volar plating (VP) and external fixation (EF) for distal intraarticular radius fractures two yearspostoperatively.Materials and methods: This retrospective study included 59 patients with 62 intraarticular AO Type C distal radius fractures.
💡
Conclusion & Impact:Function is not restored to the functionalityof the contralateral and noninjured hand.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background/aim: Surgical treatment of distal intraarticular radius fractures remains controversial. Our aim was to compare the clinicaland radiological outcomes between volar plating (VP) and external fixation (EF) for distal intraarticular radius fractures two yearspostoperatively.Materials and methods: This retrospective study included 59 patients with 62 intraarticular AO Type C distal radius fractures. Wedistinguished two groups: patients treated with internal fixation (volar locking plate, VP group: 41 fractures), and patients treated withan external fixator and K-wires (EF group: 21 fractures). The clinical assessment included range of motion, grip strength, disability of thearm, shoulder, and hand (DASH), and visual analog scale scores. Radiological measurements comprised flexion and extension, radialvolar tilt, inclination, height, shortening, and ulnar variance.Results: Postoperative grip strength and flexion angles were better after VP (P = 0.004, P = 0.009), but there was no difference in DASHscores (P = 0.341). Radial inclination was significantly different compared to that of the uninjured hand after VP (P = 0.0183), but notEF (P = 0.11).Conclusion: VP and EF result in similar clinical and radiological outcomes after 2 years. Function is not restored to the functionalityof the contralateral and noninjured hand.

🔖

Cite This Article

ÖZDEMİR, U., BİNGÖL, İ., BAYAM, L., ÇİÇEKLİ, Ö., ŞÜKÜR, E., KOCHAİ, A. (2022). Comparison of 2-year clinical and radiological outcomes between volar plating and external fixation with additional K-wires for AO Type C distal radius fractures. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 5, 1418–1425. https://ajindex.com/articles/610208

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Dario P, Matteo G, Carolina C, Marco G, Cristina D et al. Is it really necessary to restore radial anatomic parameters after distal radius fractures? Injury 2014; 45(Supplement 6): 21-26
  2. O’Neill TW, Cooper C, Finn JD, Lunt M, Purdie D et al. Incidence of distal forearm fracture in British men and women. Osteoporosis International 2001; 12(7): 555-558
  3. Singer BR, McLauchlan GJ, Robinson CM, Christie J. Epidemiology of fractures in 150,000 adults: the influence of age and gender. Journal of Bone and Joint Surgery, British Volume 1998; 80(2): 243-248
  4. Kopylov P, Johnell O, Redlund-Johnell L, Bengner U. Fractures of the distal end of the radius in young adults: a 30-year followup. Journal of Hand Surgery, British Volume 1993; 18(1): 45- 49
  5. Melton LJ III, Amadio PC, Crowson CS, O’Fallon WM. Long-term trends in the incidence of distal forearm fractures. Osteoporosis International 1998; 8(4): 341-348
  6. Nellans KW, Kowalski E, Chung KC. The epidemiology of distal radius fractures. Hand Clinics 2012; 28(2): 113-125
  7. Roh YH, Lee BK, Baek JR, Noh JH, Gong HS et al. A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. Journal of Hand Surgery, American Volume 2015; 40(1): 34-41
  8. Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC et al. Treatment of unstable distal radial fractures with the volar locking plating system. Journal of Bone and Joint Surgery, American Volume 2006; 88(12): 2687-2694
  9. Orbay JL, Touhami A. Current concepts in volar fixedangle fixation of unstable distal radius fractures. Clinical Orthopaedics and Related Research 2006; 445: 58-67
  10. Mignemi ME, Byram IR, Wolfe CC, Fan KH, Koehler EA et al. Radiographic outcomes of volar locked plating for distal radius fractures. Journal of Hand Surgery, American Volume 2013; 38(1): 40-48
  11. Kumbaraci M, Kucuk L, Karapinar L, Kurt C, Coskunol E. Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures. European Journal of Orthopaedic Surgery and Traumatology 2014; 24(2): 173-178
  12. Jeudy J, Steiger V, Boyer P, Cronier P, Bizot P et al. Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation ‘versus’ locked volar plating. Injury 2012; 43(2): 174-179