Journals / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 6

The role of right ventricular volumes and inferior vena cava diameters in the evaluation of volume status before colonoscopy

Pages
1606–1613
Publication Date
2022-11-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Logisticregression analysis showed that dIVC min and RV-ESA were independent predictors of hypotension.Conclusion: IVC diameters and RV-ESA, RV-EDA, RV-ESV, and RV-EDV are good indicators of preoperative volume status and can beused to predict the patients at risk of developing hypotension.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: Ultrasonographic measurements of inferior vena cava (IVC) diameters and right ventricle (RV) volumes areimportant tools for the evaluation of intravascular volume.
📊
Key Findings & Data:Postanesthesia hypotension wasdefined as mean arterial blood pressure of 30% in the mean arterial pressure after sedation.Results: Minimum and maximum IVC diameters were significantly lower (P = 0.005 and P < 0.001, respectively) and IVC-CI wassignificantly higher (P < 0.001) in patients who developed hypotension.
💡
Conclusion & Impact:Logisticregression analysis showed that dIVC min and RV-ESA were independent predictors of hypotension.Conclusion: IVC diameters and RV-ESA, RV-EDA, RV-ESV, and RV-EDV are good indicators of preoperative volume status and can beused to predict the patients at risk of developing hypotension.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background/aim: Ultrasonographic measurements of inferior vena cava (IVC) diameters and right ventricle (RV) volumes areimportant tools for the evaluation of intravascular volume. The current study investigates the association of IVC diameters and RVvolumes before colonoscopy in prediction of postanesthesia hypotension.Materials and methods: Seventy patients scheduled for colonoscopy were included in the study. Preoperatively, expirium (dIVC max)and inspirium (dIVC min) IVC diameters were measured using M-mode ultrasonography and the collapsibility index (IVC-CI) wascalculated. Ventricular volumes and areas were also measured using transthoracic echocardiography. Postanesthesia hypotension wasdefined as mean arterial blood pressure of 30% in the mean arterial pressure after sedation.Results: Minimum and maximum IVC diameters were significantly lower (P = 0.005 and P < 0.001, respectively) and IVC-CI wassignificantly higher (P < 0.001) in patients who developed hypotension. Similarly, right ventricular end-diastolic area (RV-EDA), rightventricular end-systolic area (RV-ESA), right ventricular end-diastolic volume (RV-EDV), right ventricular end-systolic volume (RVESV), and left ventricular end-systolic volume (LV-ESV) values were significantly lower in patients with hypotension (P < 0.05). Logisticregression analysis showed that dIVC min and RV-ESA were independent predictors of hypotension.Conclusion: IVC diameters and RV-ESA, RV-EDA, RV-ESV, and RV-EDV are good indicators of preoperative volume status and can beused to predict the patients at risk of developing hypotension.

🔖

Cite This Article

ASIL, M., TOPAL, A., HACIBEYOĞLU, G., UZUN, S. T., ARICAN, S., KOYUNCU, M., DERTLİ, R., DAĞLI, Ç. (2022). The role of right ventricular volumes and inferior vena cava diameters in the evaluation of volume status before colonoscopy. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 6, 1606–1613. https://ajindex.com/articles/609980

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Lonjaret L, Lairez O, Minville V, Geeraerts T. Optimal perioperative management of arterial blood pressure. Integrated Blood Pressure Control 2014
  2. 12 (7): 49-59. doi: 10.2147/IBPC. S45292 2. Kratz T, Campo Dell’Orto M, Exner M, Timmesfeld N, Zoremba M et al. Focused intraoperative transthoracic echocardiography by anesthesiologists: a feasibility study. Minerva Anestesiologica 2015
  3. 81 (5): 490-496. 3. Charlson ME, MacKenzie CR, Gold JP, Ales KL, Topkins M et al. Preoperative characteristics predicting intraoperative hypotension and hypertension among hypertensives and diabetics undergoing noncardiac surgery. Annals of Surgery 1990
  4. Marik PE, Lemson J. Fluid responsiveness: an evolution of our understanding British Journal of Anaesthesia 2014
  5. 112 (4): 617-620. doi: 10.1093/bja/aet590 5. Brennan JM, Ronan A, Goonewardena S, Blair JE, Hammes M et al. Hand carried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic. Clinical Journal of the American Society of Nephrology 2006
  6. 1 (4): 749-753. 6. DeCara JM, Lang RM, Koch R, Bala R, Penzotti J et al. The use of small personal ultrasound devices by internists without formal training in echocardiography. European Journal of Echocardiography 2002
  7. Kirkpatrick JN, Belka V, Furlong K, Balasia B, Jacobs LD et al. Effectiveness of echocardiographic imaging by nurses to identify left ventricular systolic dysfunction in high-risk patients. American Journal of Cardiology 2005
  8. Zhang J, Critchley LA. Inferior vena cava ultrasonography before general anesthesia can predict hypotension after induction. Anesthesiology 2016
  9. 124 (3): 580-589. doi: 10.1097/ ALN.0000000000001002 9. Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008
  10. Cecconi M, Aya HD. Central venous pressure cannot predict fluid-responsiveness. BMC Evidence-Based Medicine 2014
  11. 19 (2): 63. 11. Shah MR, Hasselblad V, Stevenson LW, Binanay C, O’Connor CM et al. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA 2005
  12. 294 (13): 1664-1670. 12. Junghans T, Neuss H, Strohauer M, Raue W, Haase O et al. Hypovolemia after traditional preoperative care in patients undergoing colonic surgery is underrepresented in conventional hemodynamic monitor