CONCLUSION: The corrected carotid Doppler flow time measurements in patients with GI bleeding at the time of presenting to the emergency department can be helpful to interpret the active bleeding.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:INTRODUCTION: Because of the subjectivity and ambiguity of the noninvasive measurements and limited use of invasive ones, there is an impending need for a real‑time, fast, inexpensive, and reproducible noninvasive measurement method in acute upper gastrointestinal (GI) bleeding with active bleeding in emergency services.
📊
Key Findings & Data:RESULTS: A total of 94 patients, including 50 patients with GI bleeding and 44 healthy volunteers as control group were included in the study.
💡
Conclusion & Impact:CONCLUSION: The corrected carotid Doppler flow time measurements in patients with GI bleeding at the time of presenting to the emergency department can be helpful to interpret the active bleeding.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

INTRODUCTION: Because of the subjectivity and ambiguity of the noninvasive measurements and limited use of invasive ones, there is an impending need for a real‑time, fast, inexpensive, and reproducible noninvasive measurement method in acute upper gastrointestinal (GI) bleeding with active bleeding in emergency services. AIMS: In this study, we aimed to evaluate the effect of bedside carotid artery flow time (CFT) measurement before and after the passive leg raising (PLR) maneuver on the determination of active bleeding in patients admitted to the emergency department (ED) with upper GI bleeding. MATERIALS AND METHODS: This prospective case–control study was conducted in the ED of a training and research hospital with upper GI bleeding. Patients were placed in the supine position to perform bedside carotid Doppler ultrasonography before starting treatment. CFT, corrected CFT (CFTc), and carotid artery Doppler flow velocity were measured. After then performed PLR, the same parameters were measured again. RESULTS: A total of 94 patients, including 50 patients with GI bleeding and 44 healthy volunteers as control group were included in the study. CFT and CFTc were shorter in the patient group than the control group (P < 0.001, P = 0.004, respectively). After PLR, there were statistically significant differences in change in the CFT (ΔCFT) and change in the corrected CFT (ΔCFTc) between the groups (P = 0.001, P < 0.001). There were also statistically significant differences in ΔCFT and ΔCFT between the patients with active bleeding and the nonbleeding ones (P = 0.01, P = 0.005, respectively). Area under curve to detect active bleeding for ΔCFT and ΔCFTc were calculated as 0.801 (95% confidence interval [CI]: 0.65–0.95) and 0.778 (95% CI: 0.63–0.91), respectively. CONCLUSION: The corrected carotid Doppler flow time measurements in patients with GI bleeding at the time of presenting to the emergency department can be helpful to interpret the active bleeding.

🔖

Cite This Article

EMEKTAR, E., KARADADAŞ, S., DAĞAR, S., ÇORBACIOĞLU, Ş. K., ÇEVİK, Y. (2022). Assessment of the carotid artery Doppler flow time in patients with acute upper gastrointestinal bleeding. Turkish journal of emergency medicine (Online), Cilt: 20 - Sayı: 1, 35–41. https://ajindex.com/articles/605236

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 2011;39:259‑65
  2. Arikan AA, Zappitelli M, Goldstein SL, Naipaul A, Jefferson LS, Loftis LL. Fluid overload is associated with impaired oxygenation and morbidity in critically ill children. Pediatr Crit Care Med 2012;13:253‑8
  3. Vaara ST, Korhonen AM, Kaukonen KM, Nisula S, Inkinen O, Hoppu S, et al. Fluid overload is associated with an increased risk for 90‑day mortality in critically ill patients with renal replacement therapy: Data from the prospective FINNAKI study. Crit Care 2012;16:R197
  4. Magee G, Zbrozek A. Fluid overload is associated with increases in length of stay and hospital costs: Pooled analysis of data from more than 600 US hospitals. Clinicoecon Outcomes Res 2013;5:289‑96
  5. Lanas A, García‑Rodríguez LA, Polo‑Tomás M, Ponce M, Alonso‑Abreu I, Perez‑Aisa MA, et al. Time trends and impact of upper and lower gastrointestinal bleeding and perforation in clinical practice. Am J Gastroenterol 2009;104:1633‑41
  6. Mackenzie DC, Noble VE. Assessing volume status and fluid responsiveness in the emergency department. Clin Exp Emerg Med 2014;1:67‑77
  7. Marik PE, Monnet X, Teboul JL. Hemodynamic parameters to guide fluid therapy. Ann Intensive Care 2011;1:1
  8. Mackenzie DC, Khan NA, Blehar D, Glazier S, Chang Y, Stowell CP, et al. Carotid flow time changes with volume status in acute blood loss. Ann Emerg Med 2015;66:277‑820
  9. Antiperovitch P, Iliescu E, Chan B. Carotid systolic flow time with passive leg raise correlates with fluid status changes in patients undergoing dialysis. J Crit Care 2017;39:83‑6
  10. Shokoohi H, Berry GW, Shahkolahi M, King J, King J, Salimian M, et al. The diagnostic utility of sonographic carotid flow time in determining volume responsiveness. J Crit Care 2017;38:231‑5
  11. Blehar DJ, Glazier S, Gaspari RJ. Correlation of corrected flow time in the carotid artery with changes in intravascular volume status. J Crit Care 2014;29:486‑8
  12. Hossein‑Nejad H, Mohammadinejad P, Lessan‑Pezeshki M, Davarani SS, Banaie M. Carotid artery corrected flow time measurement via bedside ultrasonography in monitoring volume status. J Crit Care 2015;30:1199‑203
  13. Juhl‑Olsen P, Vistisen ST, Christiansen LK, Rasmussen LA, Frederiksen CA, Sloth E. Ultrasound of the inferior vena cava does not predict hemodynamic response to ea