Journals / Turkish Journal of Chemistry / 2020 / Cilt: 44 - Sayı: 6

Highly luminescent water-dispersed silicon quantum dots for fluorometric determination of oxytetracycline in milk samples

Pages
1713–1722
Publication Date
2022-11-03
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This simple, selective, sensitive, rapid, and cheap method can be used as a promising tool for OTC analysis in food safety.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A fluorescent probe based on silicon quantum dots (SiQDs) was developed for the selective and sensitive detection of oxytetracycline (OTC) via the inner filter effect (IFE).
📊
Key Findings & Data:The water-soluble fluorescent SiQD was synthesized based on the reaction of 3-Aminopropyltriethoxysilane (APTES) and sodium citrate as precursors by the one-pot hydrothermal process.
💡
Conclusion & Impact:This simple, selective, sensitive, rapid, and cheap method can be used as a promising tool for OTC analysis in food safety.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

A fluorescent probe based on silicon quantum dots (SiQDs) was developed for the selective and sensitive detection of oxytetracycline (OTC) via the inner filter effect (IFE). The water-soluble fluorescent SiQD was synthesized based on the reaction of 3-Aminopropyltriethoxysilane (APTES) and sodium citrate as precursors by the one-pot hydrothermal process. The strong fluorescence emission of quantum dots (QDs) was obtained at 440 nm when excited at 350 nm and OTC had a broad absorption band between 200 and 400 nm. The excitation spectrum of SiQDs was completely overlapped with the absorption spectrum of OTC. The light at an excitation wavelength of QDs absorbed by OTC caused a decrease in fluorescence intensity with an increase in the concentration of OTC. Under optimal conditions, the linear concentration range was 0.92–9.2 µg mL1 with a detection limit (LOD; S/N = 3) of 0.19 µg $mL^{–1}$. The proposed method was applied to the determination of OTC in milk samples and satisfactory recoveries (98.8–100.5%) with low RSD % values (0.93–2.31%) were achieved. This simple, selective, sensitive, rapid, and cheap method can be used as a promising tool for OTC analysis in food safety.

🔖

Cite This Article

DEMİRHAN, B., DEMİRHAN, B. E., KARA, H. E. Ş. (2022). Highly luminescent water-dispersed silicon quantum dots for fluorometric determination of oxytetracycline in milk samples. Turkish Journal of Chemistry, Cilt: 44 - Sayı: 6, 1713–1722. https://ajindex.com/articles/601878

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Batchelder AR. Chlortetracycline and oxytetracycline effects on plant growth and development in liquid cultures. Journal of Environmental Quality 1981
  2. 10 (4): 515-518. doi: 10.2134/jeq1981.00472425001000040019x 2. Chopra I, Roberts M. Tetracycline antibiotics: Mode of action, applications, molecular biology, and epidemiology of bacterial resistance. Microbiology and Molecular Biology Reviews 2001
  3. 65 (2): 232-260. doi: 10.1128/mmbr.65.2.232-260.2001 3. He B, Wang L, Dong X, Yan X, Li M, et al. Aptamer-based thin film gold electrode modified with gold nanoparticles and carboxylated multi-walled carbon nanotubes for detecting oxytetracycline in chicken samples. Food Chemistry 2019
  4. 125179. doi: 10.1016/j. foodchem.2019.125179 4. Furusawa N. Clean and rapid liquid chromatographic technique for monitoring of oxytetracycline and sulphadimidine in milk without use of organic solvents. Chromatographia 2003
  5. 57 (5/6): 317-320. doi: 10.1007/bf02492402 5. Kurjogi M, Mohammad YHI, Alghamdi S, Abdelrahman M, Satapute P et al. Detection and determination of stability of the antibiotic residues in cow’s milk. PLoS ONE 2019
  6. 14 (10): e0223475. doi: 10.1371/journal.pone.0223475 6. Wang Z, Wang XY, Tian H, Wei QH, Liu BS et al. High through – put determination of 28 veterinary antibiotic residues in swine wastewater by one – step dispersive solid phase extraction sample cleanup coupled with ultra – performance liquid chromatography – tandem mass spectrometry. Chemosphere 2019
  7. doi: 10.1016/j.chemosphere.2019.05.047 7. Marinou E, Samanidou VF, Papadoyannis IN. Development of a high pressure liquid chromatography with diode array detection method for the determination of four tetracycline residues in milk by using QuEChERS dispersive extraction. Separations 2019
  8. 6 (2): 21. doi: 10.3390/separations6020021 8. Li J, Zeng W, Lai X, Wang X, Xu X et al. Selective and sensitive determination of tetracyclines by HPLC with chemiluminescence detection based on a cerium(IV) – methoxylated cypridina luciferin analogue system. Journal of Separation Science 2018
  9. 41 (22): 4115-4121. doi: 10.1002/jssc.201800683 9. Wu XY, Xu ZQ, Huang Z, Shao CY. Large volume sample stacking of cationic tetracycline antibiotics toward 10 ppb level analysis by capillary electrophoresis with UV detection. Electrophoresis 2016
  10. 37 (22): 2963-2969. doi: 10.1002/elps.201600189 10. Paul P, Reynaert J, Sänger-van de Griend C, Adams E, Schepdael AV. Development and validation of a CE method