Journals / Turkish Journal of Chemistry / 2022 / Cilt: 46 - Sayı: 2

Preconcentration of trace amount Cu(II) by solid-phase extraction method using activated carbon-based ion-imprinted sorbent

Pages
550–566
Publication Date
2022-11-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Good and quantitative recoveries were obtained for the spiked analysis.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, preconcentration conditions of trace amounts of copper ions were investigated with solid-phase extraction (SPE) method by synthesizing activated carbon-based ion-imprinted sorbent (Cu(II)-IAC) with a novel and selective approach.
📊
Key Findings & Data:Optimum conditions for the SPE procedure, various parameters such as pH value, eluent type and concentration, sample volume, sample flow rate, adsorption capacity, and selectivity were studied.
💡
Conclusion & Impact:Good and quantitative recoveries were obtained for the spiked analysis.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, preconcentration conditions of trace amounts of copper ions were investigated with solid-phase extraction (SPE) method by synthesizing activated carbon-based ion-imprinted sorbent (Cu(II)-IAC) with a novel and selective approach. Flame atomic absorption spectrometry (FAAS) was used for the determination of metal ions concentrations. For the characterization of the sorbents, scanning electron microscopy, energy dispersive X-ray (SEM/EDX) analysis, and Fourier transform infrared spectroscopy (FTIR) were used. Optimum conditions for the SPE procedure, various parameters such as pH value, eluent type and concentration, sample volume, sample flow rate, adsorption capacity, and selectivity were studied. The adsorption isotherm was analyzed by Freundlich and Langmuir isotherm, and the maximum adsorption capacity was found to be 142.9 and 312.5 mg/g for activated carbon-based nonimprinted (Cu(II)-non-IAC) and Cu(II)-IAC sorbents, respectively from the Langmuir isotherm. Limit of determination (LOD) and limit of quantification (LOQ) values were found to be 0.038 and 0.113 µg/L, respectively for Cu(II)-IAC sorbent, and the results were compared with the literature. The accuracy and validity of the proposed method were evaluated by the determination of Cu(II) ions from tap water samples and certified reference materials (CRMs) (soft drinking water ERML-CA021e and NIST 1643e) analysis. Good and quantitative recoveries were obtained for the spiked analysis.

🔖

Cite This Article

CANLIDİNÇ, R. S., TURAN, K., KALFA, O. M. (2022). Preconcentration of trace amount Cu(II) by solid-phase extraction method using activated carbon-based ion-imprinted sorbent. Turkish Journal of Chemistry, Cilt: 46 - Sayı: 2, 550–566. https://ajindex.com/articles/601387

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Türker AR. Separation, Preconcentration and speciation of metal ions by sorbent extraction. Separation and Purification Reviews 2012
  2. 41 (3): 169-206. doi: 10.1080/15422119.2011.585682 2. Mendil D, Karata M, Tuzen, M. Separation and preconcentration of Cu(II), Pb(II), Zn(II), Fe(III) and Cr(III) ions with coprecipitation method without carrier element and their determination in food and water samples. Food Chemistry 2015
  3. 320–324. doi: 10.1016/j. foodchem.2015.01.008 3. Öztürk Er E, Maltepe E, Bakirdere SA. Novel analytical method for the determination of cadmium in sorrel and rocket plants at ultratrace levels: Magnetic chitosan hydrogels based sorbent microextraction-slotted quartz tube-flame atomic absorption spectrophotometry. Microchemical Journal 2018
  4. 393–399. doi: 10.1016/j.microc.2018.08.019 4. Lingamdinne LP, Koduru JR, Chang Y-Y, Karri RR. Process optimization and adsorption modeling of Pb(II) on nickel ferrite-reduced graphene oxide nano-composite. Journal of Molecular Liquids 2018
  5. 202–211. doi: 10.1016/j.molliq.2017.11.174 5. Ahmad H, Cai C, Liu C. Separation and preconcentration of Pb(II) and Cd(II) from aqueous samples using hyperbranched polyethyleneimine-functionalized graphene oxide-immobilized polystyrene spherical adsorbents. Microchemical Journal 2019
  6. 833– 842. doi: 10.1016/j.microc.2018.11.032 6. Tuzen M. Toxic and essential trace elemental contents in fish species from the Black Sea, Turkey. Food and Chemical Toxicology 2009
  7. 1785–1790. doi: 10.1016/j.fct.2009.04.029 7. Yalçın MS, Özdemir S, Kılınç E. Preconcentrations of Ni(II) and Co(II) by using immobilized thermophilic Geobacillus stearothermophilus SO-20 before ICP-OES determinations. Food Chemistry 2018
  8. 126–132. doi: 10.1016/j.foodchem.2018.05.103 8. Özdemir S, Yalçın MS, Kılınç E, Soylak M. Comparison of Cd(II) preconcentrations by using magnetized Pleurotus erygnii and Coprinus micaceus and its determination in real samples. Microchemical Journal 2019
  9. 19–25. doi: 10.1016/j.microc.2018.08.039 9. Ahmad H, Huang Z, Kanagaraj P, Liu C. Separation and preconcentration of arsenite and other heavy metal ions using graphene oxide laminated with protein molecules. Journal of Hazardous Materials 2020
  10. 121479. doi: 10.1016/j.jhazmat.2019.121479 10. Saygılı Canlıdinç R, Kalfa OM, Üstündağ Z, Erdoğan Y. Graphene oxide modified expanded perlite as a new sorbent for Cu(II) and Pb(II) prior to determination by high-resolution continuum source fla