Journals / Turkish Journal of Chemistry / 2022 / Cilt: 46 - Sayı: 1

Supramolecular solvent-based microextraction for the preconcentration of $Pb^{2+} and Cd2^{+}$ prior to spectrophotometric detection

Pages
147–156
Publication Date
2022-11-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results obtained revealed that the developed method is rapid, simple, sensitive, and efficient for the determination of both analytes in real water samples.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Supramolecular solvent-based dispersive liquid–liquid microextraction technique has been developed as a preconcentration tool for the determination of trace level of $Pb^{2+} and Cd2^{+}$ .
📊
Key Findings & Data:Both $Pb^{2+} and Cd2^{+}$ , which were efficiently extracted by supramolecular solvent system, were complexed with dithizone followed by the addition of supramolecular solvent.
💡
Conclusion & Impact:The results obtained revealed that the developed method is rapid, simple, sensitive, and efficient for the determination of both analytes in real water samples.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Supramolecular solvent-based dispersive liquid–liquid microextraction technique has been developed as a preconcentration tool for the determination of trace level of $Pb^{2+} and Cd2^{+}$ . Dodecanol dispersed in tetrahydrofuran has been utilized as a supramolecularsolvent system for the extraction of analytes prior to their quantitative determination with graphite furnace atomic absorption spectrophotometer. Both $Pb^{2+} and Cd2^{+}$ , which were efficiently extracted by supramolecular solvent system, were complexed with dithizone followed by the addition of supramolecular solvent. The experimental variables that could possibly influence the extraction efficiency, i.e. pH value, temperature, sample volume, centrifugation time, rate of centrifugation, ionic strength, etc. were subjected to the optimization step. An interference study was also conducted to check the selectivity of developed method. Limit of detection calculated for $Pb^{2+} and Cd2^{+}$was 0.015 and 0.061 mg L–1, respectively. The limit of quantification was 0.05 and 0.2 mg $L{–1} for Pb^{2+} and Cd2^{+}$ , respectively. The analytical signal was enhanced to 30 times in case of Pb2+ and 27 times in case of $Cd^{2+}$. The results obtained revealed that the developed method is rapid, simple, sensitive, and efficient for the determination of both analytes in real water samples.

🔖

Cite This Article

KHAN, R. A., ISMAIL, B., KHAN, A. M., ZAFAR, H., NISAR, J., SHAH, F. (2022). Supramolecular solvent-based microextraction for the preconcentration of $Pb^{2+} and Cd2^{+}$ prior to spectrophotometric detection. Turkish Journal of Chemistry, Cilt: 46 - Sayı: 1, 147–156. https://ajindex.com/articles/601340

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Tchounwou PB, Yedjou CG, Patlolla AK, Sutton DJ. Heavy Metals Toxicity and the Environment EXS 2012; 101: 133-64
  2. Babel S, Kurniawan TA. Low-cost adsorbents for heavy metals uptake from contaminated water: a review. Journal of Hazardous Materials 2003; 97: 219-43
  3. Guptra P, Sharma K. Heavy Metal Contamination. International Jorunal of Advance Reserch 2013; 2: 1043-55
  4. Waalkes MP. Cadmium carcinogenesis in review. Journal of Inorganic Biochemistry 2000; 79: 241-4
  5. Järup L. Hazards of heavy metal contamination. British Medical Bulletin 2003; 68: 167-82
  6. Flora G, Gupta D, Tiwari A. Toxicity of lead: A review with recent updates. Interdisciplinary Toxicology 2012; 5: 47-58
  7. Satarug S, Baker JR, Urbenjapol S, Haswell-Elkins M, Reilly PE et al. A global perspective on cadmium pollution and toxicity in nonoccupationally exposed population. Toxicology Letters 2003; 137: 65-83
  8. Siegel FR. Environmental geochemistry of potentially toxic metals. Springer; 2002
  9. Goyer RA. Lead toxicity: current concerns. Environmental Health Perspectives 1993; 100: 177-87
  10. Soodan RK, Pakade YB, Nagpal A, Katnoria JK. Analytical techniques for estimation of heavy metals in soil ecosystem: A tabulated review. Talanta 2014; 125: 405-10
  11. Sereshti H, Khojeh V, Samadi S. Optimization of dispersive liquid–liquid microextraction coupled with inductively coupled plasmaoptical emission spectrometry with the aid of experimental design for simultaneous determination of heavy metals in natural waters. Talanta 2011; 83: 885-90
  12. Saracoglu S, Soylak M, Elci L. Separation/preconcentration of trace heavy metals in urine, sediment and dialysis concentrates by coprecipitation with samarium hydroxide for atomic absorption spectrometry. Talanta 2003; 59: 287-93
  13. Bulut VN, Gundogdu A, Duran C, Senturk HB, Soylak M et al. A multi-element solid-phase extraction method for trace metals determination in environmental samples on Amberlite XAD-2000. Journal of Hazardous Materials 2007; 146: 155-63
  14. Rezaee M, Assadi Y, Hosseini M-RM, Aghaee E, Ahmadi F et al. Determination of organic compounds in water using dispersive liquid– liquid microextraction. Journal of Chromatography A 2006; 1116: 1-9
  15. Martínez-Rubio D, Grindlay G, Llaver M, Wuilloud RG, Mora J. Development of preconcentration strategies for the simultaneous ultratrace determination of As, Cd and Pb in foods by ICP-OES: knotted-reactor vs. dispersive liquid–liquid microextraction. Journal of Analytical At