Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation

Pages
532–542
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: High density of right fibrous trigone is independently associated with con- duction disturbance after transcatheter aortic valve implantation, and its pre-proce- dure computed tomography evaluation can help predict the new-onset of conduction disturbance.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background: The right fibrous trigone, which the His bundle penetrates, is part of the subaortic area adjacent to the membranous septum.
📊
Key Findings & Data:Methods: We retrospectively examined 209 patients who underwent transfemoral transcatheter aortic valve implantationat a tertiary cardiac center.
💡
Conclusion & Impact:Conclusion: High density of right fibrous trigone is independently associated with con- duction disturbance after transcatheter aortic valve implantation, and its pre-proce- dure computed tomography evaluation can help predict the new-onset of conduction disturbance.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background: The right fibrous trigone, which the His bundle penetrates, is part of the subaortic area adjacent to the membranous septum. Structural alterations of the right fibrous trigone may cause conduction disturbance as a result of compression in this area after transcatheter aortic valve implantation. This study analyzed the hypothesis of whether imaging parameters of the RFT could predict the risk of conduction disturbance after transcatheter aortic valve implantation. Methods: We retrospectively examined 209 patients who underwent transfemoral transcatheter aortic valve implantationat a tertiary cardiac center. The different valve models were divided into 2 groups: self-expanding valve and balloon-expandable valve. Using pre-procedure computed tomography, we evaluated for the alterations of the right fibrous trigone. Results: New conduction disturbance was seen in 75 of 209 (35.8%) patients. Receiver operating characteristics plots displayed a right fibrous trigone density of −6 Hounsfield unit for SEV and −16 Hounsfield unit for balloon-expandable valve as the optimal cut - off points for prediction conduction disturbance. In multiple regression analyses, the high density of RFT emerged as an independent predictor of conduction disturbance in both the self-expanding valve (odds ratio: 1.01, 95% CI: 1.01 to 1.02, P = 0.035) and bal- loon-expandable valve (odds ratio: 1.01, 95% CI: 1.01 to 1.03, P = 0.017) groups. A shorter membranous septum length and a greater implantation depth were also found to be significantly associated with a higher incidence of conduction disturbance in both trans- catheter aortic valve implantation groups. Conclusion: High density of right fibrous trigone is independently associated with con- duction disturbance after transcatheter aortic valve implantation, and its pre-proce- dure computed tomography evaluation can help predict the new-onset of conduction disturbance.

🔖

Cite This Article

Aslan, S., Türkvatan, A., Topel, Ç., Güner, A., Demir, A. R., Kahraman, S., Çelik, Ö., Ertürk, M. (2022). Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation. The Anatolian Journal of Cardiology, Cilt: 26 - Sayı: 7, 532–542. https://ajindex.com/articles/597225

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. van Rosendael PJ, Delgado V, Bax JJ. Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J. 2018
  2. 39(21):2003-2013. [CrossRef] 2. Regueiro A, Abdul-Jawad Altisent O, Del Trigo M, et al. Impact of new-onset left bundle branch block and periprocedural per- manent pacemaker implantation on clinical outcomes in patients undergoing transcatheter aortic valve replacement: A systematic review and meta-analysis. Circ Cardiovasc Interv. 2016
  3. 9(5):e003635. [CrossRef] 3. Siontis GC, Jüni P, Pilgrim T, et al. Predictors of permanent pace- maker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J Am Coll Cardiol. 2014
  4. 64(2):129-140. [CrossRef] 4. Chen S, Chau KH, Nazif TM. The incidence and impact of cardiac conduction disturbances after transcatheter aortic valve replace- ment. Ann Cardiothorac Surg. 2020
  5. 9(6):452-467. [CrossRef] 5. Mangieri A, Montalto C, Pagnesi M, et al. TAVI and post proce- dural cardiac conduction abnormalities. Front Cardiovasc Med. 2018
  6. [CrossRef] 6. Kawashima T, Sato F. Visualizing anatomical evidences on atrio- ventricular conduction system for TAVI. Int J Cardiol. 2014
  7. 174(1):1-6. [CrossRef] 7. Saremi F, Sánchez-Quintana D, Mori S, et al. Fibrous skeleton of the heart: anatomic overview and evaluation of pathologic conditions with CT and MR imaging. RadioGraphics. 2017
  8. 37(5):1330-1351. [CrossRef] 8. Mori S, Fukuzawa K, Takaya T, et al. Clinical cardiac structural anatomy reconstructed within the cardiac contour using multi- detector-row computed tomography: left ventricular outflow tract. Clin Anat. 2016
  9. 29(3):353-363. [CrossRef] 9. Saremi F, Hassani C, Sánchez-Quintana D. Septal atrioventricu- lar junction region: comprehensive imaging in adults. Radio- Graphics. 2016
  10. 36(7):1966-1986. [CrossRef] 10. Anderson RH, Yanni J, Boyett MR, Chandler NJ, Dobrzynski H. The anatomy of the cardiac conduction system. Clin Anat. 2009
  11. 22(1):99-113. [CrossRef] 11. VARC-3 WRITING COMMITTEE, Généreux P, Piazza N, et al. Valve Academic Research Consortium 3: updated endpoint def- initions for aortic valve clinical research. Eur Heart J. 2021
  12. 42(19):1825-1857. [CrossRef] 12. Petronio AS, Sinning JM, Van Mieghem N, et al. Optimal implan- tation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replace- ment with the Medtronic CoreValve system: the CoreValve pro- spective,