AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, a statistically significant increase was observed after 10000 thermocycles for both of these two materials (p=0.002 and p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background: To evaluate the mechanical and surface properties of two glass ionomer restorative systems (EQUIA Fil, Ionostar Molar) and a resin composite (Charisma Classic) after thermocycling.
📊
Key Findings & Data:After the samples were stored in distilled water at 370C for 24 h, microhardness and surface roughness measurements were performed from each group and repeated after 5000 and 10000 thermocycling.
💡
Conclusion & Impact:However, a statistically significant increase was observed after 10000 thermocycles for both of these two materials (p=0.002 and p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background: To evaluate the mechanical and surface properties of two glass ionomer restorative systems (EQUIA Fil, Ionostar Molar) and a resin composite (Charisma Classic) after thermocycling. Methods: Twenty disk-shaped samples were prepared from each material in teflon molds according to manufacturer’s instructions. After the samples were stored in distilled water at 370C for 24 h, microhardness and surface roughness measurements were performed from each group and repeated after 5000 and 10000 thermocycling. Scanning electron microscopy examinations were also performed. The data were analyzed by using Wilcoxon signed rank and Bonferroni corrected multiple comparison tests. Results: EQUIA did not exhibit significant differences in its microhardness values after thermocycling (p>0.005). In contrast, Ionostar Molar and Charisma Classic exhibited statistically significant decreases in baseline microhardness after 5000 and 10000 thermocycling processes (both p0.05). However, a statistically significant increase was observed after 10000 thermocycles for both of these two materials (p=0.002 and p

Özet

Amaç: İki cam iyonomer restoratif sistem (EQUA Fil, Ionostar Molar) ve bir kompozit rezinin ısıl döngü ile yaşlandırma sonrası mekanik ve yüzey özelliklerini değerlendirmektir. Gereç ve Yöntemler: Her materyalden 20 adet örnek üretici firma talimatları doğrultusunda hazırlandı. Örnekler 370C’de 24 saat bekletildikten sonra, mikrosertlik ve yüzey pürüzlülük ölçümleri yapıldı ve bu ölçümler 5000 ve 10000 ısıl döngü sonrasında tekrarlandı. Her gruptan bir örnek yüzey değerlendirmesi için taramalı elektron mikroskobisi ile incelendi. Veriler Wilcoxon signed rank testi ve Bonferroni düzeltmeli çoklu karşılaştırma testi kullanılarak analiz edildi. Bulgular: EQUIA, ısıl döngü sonrası mikrosertlik değerlerinde anlamlı bir farklılık göstermedi(p>0.005). Ionostar Molar ve Charisma Classic gruplarında başlangıç mikrosertlik değerlerine göre 5000 ve 10000 ısıl döngü sonrası anlamlı azalma gözlendi (p0.05). Bununla beraber, her iki materyalde de 10000 döngü sonrası yüzey pürüzlülük değerlerinde anlamlı bir azalma tespit edildi (p=0.002, p

🔖

Cite This Article

Özcan, S., Akgül, S., Üçtaşlı, M. B., Hazar, A., Yıkılgan, İ., Bala, O. (2022). Effect of Thermocycling On Mechanical and Surface Properties of Three Posterior Restorative Materials. Selcuk Dental Journal, Cilt: 8 - Sayı: 2, 32–358. https://ajindex.com/articles/591370

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. . Gurgan S, Kutuk ZB, Ergin E, Oztas SS, Cakir FY. Four- year randomized clinical trial to evaluate the clinical performance of a glass ionomer restorative system. Oper Dent. 2015;40(2):134-43. 2. Wilson AD, Kent BE. A new translucent cement for dentistry. The glass ionomer cement. Br Dent J. 1972;132(4):133-5. 3. Costa CA, Ribeiro AP, Giro EM, Randall RC, Hebling J. Pulp response after application of two resin modified glass ionomer cements (RMGICs) in deep cavities of prepared human teeth. Dent Mater. 2011;27(7):e158-70. 4. Cehreli SB, Tirali RE, Yalcinkaya Z, Cehreli ZC. Microleakage of newly developed glass carbomer cement in primary teeth. European journal of dentistry. 2013;7(1):15-21. 5. Naasan MA, Watson TF. Conventional glass ionomers as posterior restorations. A status report for the American Journal of Dentistry. Am J Dent. 1998;11(1):36-45. 6. Ilie N, Hickel R, Valceanu AS, Huth KC. Fracture toughness of dental restorative materials. Clin Oral Investig. 2012;16(2):489-98. 7. Gjorgievska E, Van Tendeloo G, Nicholson JW, Coleman NJ, Slipper IJ, Booth S. The incorporation of nanoparticles into conventional glass-ionomer dental restorative cements. Microsc Microanal. 2015;21(2):392- 406. 8. Moshaverinia M, Navas A, Jahedmanesh N, Shah KC, Moshaverinia A, Ansari S. Comparative evaluation of the physical properties of a reinforced glass ionomer dental restorative material. J Prosthet Dent. 2019;122(2):154-9. 9. Forte GAE. EQUIA Forte Bulk Fill,fluoride releasing, glass hybrid restorative system. 2019.October.15 [Available from: http://www.gcamerica.com/products/operatory/EQUIA_ Forte/. 10.Davidson CL. Advances in glass-ionomer cements. J Appl Oral Sci. 2006;14 Suppl:3-9. 11.Diem VTK, Tyas MJ, Ngo HC, Phuong LH, Khanh ND. The effect of a nano-filled resin coating on the 3-year clinical performance of a conventional high-viscosity glass-ionomer cement. Clinical oral investigations. 2014;18(3):753-9. 12.Collado-González M, Pecci-Lloret MR, Tomás-Catalá CJ, et al. Thermo-setting glass ionomer cements promote variable biological responses of human dental pulp stem cells. Dental Materials. 2018;34(6):932-43. 13.13. Wilson AD. Resin-modified glass-ionomer cements. International Journal of Prosthodontics. 1990;3(5). 14.McLean JW. The clinical use of glass-ionomer cements. Dent Clin North Am. 1992;36(3):693-711. 15.Goldman M. Fracture properties of composite and glass ionomer dental restorative materials. Journal of biomedical materials research. 1985;19(7)