Journals / Megaron / 2022 / Cilt: 17 - Sayı: 2

A comparative analysis of energy performance for external wall types in practice

Journal
Megaron
Pages
357–370
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results of the study contribute to the country's economy by ensuring the efficient use of resources.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Urban regeneration has accelerated after the establishment of the Law on Transformation of Areas Under Disaster Risk and has been carried out intensively.
📊
Key Findings & Data:This study aims to analyse the energy performance of external walls in new buildings constructed after 2012 in the Suadiye Neighbourhood and to determine the most appropriate wall section.
💡
Conclusion & Impact:The results of the study contribute to the country's economy by ensuring the efficient use of resources.
🔬Design:Research Article
📍Scope:2012 Verileri
⚙️Variables:Domain Parameters

Abstract

Urban regeneration has accelerated after the establishment of the Law on Transformation of Areas Under Disaster Risk and has been carried out intensively. Building renewal, especially at a parcel scale, cannot deal with environmental problems on an urban scale and accordingly, the sustainability principles cannot be addressed holistically. Since building renewal at a parcel scale affects a large area throughout the city, it is required to include design criteria for environmental impacts. In this context, it is important to reduce heating and cooling energy consumption, which constitutes a large part of the total energy consumed in the use of buildings, and to take environmental measures. This study aims to analyse the energy performance of external walls in new buildings constructed after 2012 in the Suadiye Neighbourhood and to determine the most appropriate wall section. For this purpose, external walls were determined with a field study, and scenarios related to building orientation, the distance between buildings and external wall sections were created on a sample building. The scenarios were analysed with DesignBuilder simulation and TS825 calculation. The results for the scenarios were evaluated comparatively. The study differs from existing studies with its scope by dealing with both building renewal and energy efficiency and analysing the external wall types in different scenarios with DesignBuilder and TS825 for the temperate humid climate zone. As a result of the study, the most suitable wall sections for the scenarios were determined and suggestions were developed. The results of the study contribute to the country's economy by ensuring the efficient use of resources.

🔖

Cite This Article

LİMONCU, S., YENİDÜNYA, S. S. (2022). A comparative analysis of energy performance for external wall types in practice. Megaron, Cilt: 17 - Sayı: 2, 357–370. https://ajindex.com/articles/579877

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. Akbulut, M. R. (1994).
  2. Kadıköy. In İstanbul Ansiklopedisi, Cilt 4 (pp. s. 329–339). İstanbul: Türkiye Ekonomik ve Toplumsal Tarih Vakfı, T.C. Kültür Bakanlığı. Aksöz, H. (2009). Betonarme Binalarda Uygulanan Isı Yalıtım Amaçlı Duvar Elemanlarının Isıl ve Ekonomik Yönden Analizi. Tekirdağ: Namık Kemal Üniversitesi Fen Bilimleri Enstitüsü. Baykal, C. (2014). Binalarda Yönlere Göre Yalıtım Kalınlığının Ekonomikliğinin Araştırılması. İstanbul: Yıldız Teknik Üniversitesi Fen Bilimleri Enstitüsü. Biseniece, E., Zogla, G., Kamenders, A., Purvins, R., Kass, K., Vanaga, R., and Blumberga, A. (2017). Thermal performance of internally insulated historic brick building in cold climate: A long term case study. Energy and Buildings 152:577–586.
  3. Chasan, S. (2013). Dış Cephe Bitirme Sistemlerinde Isı Yalıtımının Sıcaklık Ve Nem Performansına Etkisinin İncelenmesi. Edirne: Trakya Üniversitesi Fen Bilimleri Enstitüsü. Çevre ve Şehircilik Bakanlığı. (2013). BEPtr Sunumu. Retrieved 10 21, 2013, from www.csb.gov.tr Erbil, Y. and Akıncıtürk, Y. (2006). Tünel Kalıp Sistemiyle Üretilen bir Toplu Konut Örneğinin Isısal Konfor Koşulları Açısından İncelenmesi. Uludağ Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi 11(2). Erdemir, K. İ. and Koçlar, O. G. (2021). A parametric model proposal for energy efficient settlement texture and building design: Temperate-humid climate zone. Megaron 16(4):735–750.
  4. Fedorczak-Cisak, M., Furtak, M., Hayduk, G., and Kwasnowski, P. (2019). Energy analysis and cost efficiency of external partitions in low energy buildings. IOP Conference Series: Material Science and Engineering 471. Giz, A. (1994). Bir Zamanlar Kadıköy. İstanbul:
  5. İletişim Yayınları.
  6. Gorshkov, A., Vatin, N., Nemova, D., Shabaldin, A., Melnikova, L., and Kirill, P. (2015). Using life-cycle analysis to assess energy savings delivered by building insulation. International Scientific Conference Urban Civil Engineering and Municipal Facilities. Procedia Engineering v.117. Halu, Z. Y. (2010). Kentsel Mekân Olarak Caddelerin Mekânsal Karakterinin Yürünebilirlik Bağlamında İrdelenmesi, Bağdat Caddesi Örneği. İstanbul:
  7. İstanbul Teknik Üniversitesi,
  8. Fen Bilimleri Enstitüsü. Koç, R. and Altun, M. (2012). Dış Duvar Tasarımında Kullanılabilecek bir Kontrol Listesi. 6. Ulusal Çatı & Cephe Sempozyumu 12–13 Nisan 2012. Bursa: Uludağ Üniversitesi Mühendislik ve Mimarlık Fakültesi. Koçu, N. D. (2010). Dış Duvarlarda Isı Yalıtımı ile Enerji Tasarrufu Sağlanması ve Detaylarda Karşılaşılan Sorunlar (Kon