Journals / Journal of Clinical and Experimental Investigations / 2013 / Cilt: 4 - Sayı: 1

Evaluation of patients with thyrotoxic autoimmune thyroiditis by color flow doppler ultrasonography

Pages
73–79
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Heterojen echopattern, decreased echogenicity, volume changes and type 3 blood flow pattern of thyroid gland obtained using B-mode Ultrasound and CDUS may be useful in the determination and differentiation of thyrotoxic BGD and HT diseases.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: In this study, we aimed to examine the avail- ability and the effects of differential diagnosis of thyroid gland morphological changes and blood flow patterns in patients with thyrotoxic phase Graves’ disease (BGD)and Hashimoto’s thyroiditis (HT) by color flow doppler ultrasonography (CDUS).
📊
Key Findings & Data:Methods: This cross-sectional study was included 24 consecutive patients with thyrotoxicosis and 18 healthy controls.
💡
Conclusion & Impact:Conclusion: Heterojen echopattern, decreased echogenicity, volume changes and type 3 blood flow pattern of thyroid gland obtained using B-mode Ultrasound and CDUS may be useful in the determination and differentiation of thyrotoxic BGD and HT diseases.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: In this study, we aimed to examine the avail- ability and the effects of differential diagnosis of thyroid gland morphological changes and blood flow patterns in patients with thyrotoxic phase Graves’ disease (BGD)and Hashimoto’s thyroiditis (HT) by color flow doppler ultrasonography (CDUS). Methods: This cross-sectional study was included 24 consecutive patients with thyrotoxicosis and 18 healthy controls. There were Basedow-Graves’ disease in 17 andHashimoto thyroiditis in 7 of previously untreated 24 patients. Morphological information of thyroid gland was obtained by B-mode ultrasonography in all cases. Blood flow pattern of the thyroid gland was determined by CDUS. Results: The thyroid volumes and FT3, TRAb, 4-h and 24-h RAIU levels of the patients with Graves’s disease were significantly higher than the patients with HT. Whereas thyroid gland echogenicity was decreased in 14 of BGH cases, it was diminished in 2 patients with HT. Significant difference was found between BGD and HT groups in terms of thyroid gland echogenicity. In all patients with BGD and HT, echopattern was heterogenous. In all patients, blood flow patterns of thyroid gland were obtained by CDUS. Color flow doppler ultrasonography and pattern 3 blood flows were only observed in BGD. Significant difference was found between HT and BGD groups in blood flow pattern. Conclusion: Heterojen echopattern, decreased echogenicity, volume changes and type 3 blood flow pattern of thyroid gland obtained using B-mode Ultrasound and CDUS may be useful in the determination and differentiation of thyrotoxic BGD and HT diseases.

🔖

Cite This Article

ÇULLU, N., DEMİR, Y., İĞCİ, E., YENER, S., SÜRÜCÜ, E., KARAKAŞ, E., KARAKAŞ, Ö., KÜÇÜKYAVAŞ, Y. (2022). Evaluation of patients with thyrotoxic autoimmune thyroiditis by color flow doppler ultrasonography. Journal of Clinical and Experimental Investigations, Cilt: 4 - Sayı: 1, 73–79. https://ajindex.com/articles/561866

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Kumar V. Ramzi S. Cotran MD, Stanley L. Thyroid. Robbins pathologic basis of disease. Sixth Edition. Philadelphia: Saunders; 2007;1040-1131
  2. Bahn Chair RS, Burch HB, Cooper DS, et al. Hyperthyroidism and other causes of thyrotoxicosis: management guidelines of the American Thyroid Association and American Association of Clinical Endocrinolo- gists. Thyroid 2011;21:593-646
  3. Bogazzi F, Bartalena L, Brogioni S, et al. Thyroid vascularity and blood flow are not dependent on serum thyroid hormone levels: studies in vivo by color flow Doppler sonography. Eur J Endocrinol 1999;140:452- 456
  4. Erdoğan MF, Anil C, Cesur M, et al. Color flow Doppler sonography for the etiologic diagnosis of hyperthyroidism. Thyroid 2007;17:223-228
  5. Caruso G, Attard M, Caronia A, et al. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases. Eur J Radiol 2000;36:5-10
  6. Davies TF, Larsen PR. Thyrotoxicosis. Williams Text- book of Endocrinology 10th edition. PR Larsen et al (eds). WB Saunders, Philadelphia 2003;374-422
  7. Prabhakar BS, Bahn RS, Smith TJ. Current perspective on the pathogenesis of Graves’ disease and ophthalmopathy. Endocr Rev 2003;24:802-835
  8. Ginsberg J. Diagnosis and management of Graves’ disease. CMAJ 2003;168:575-585
  9. Greenspan FS. The Thyroid Gland.Basic & Clinical Endocrinology 7th edition. Greenspan FS, Gardner DG (eds). McGraw-Hill 2004;215-294
  10. Weetman AP. Graves’ disease. N Engl J Med 2000;343:1236-1248
  11. Cooper DS. Hyperthyroidism. Lancet 2003;362:459- 468
  12. Espinasse P. L’echographie thyroidienne dans les thyroidites lymphocytaires chroniques autoimmunes. J Radiology 1983;64:537-544
  13. Gutekunst R, Hafermann W, Mansky T, et al. Ultrasonography related to clinical and laboratory findings in lymphocytic thyroiditis. Acta Endocrinol 1989;121:129- 135
  14. Marcocci C, Vitti P, Cetani F, et al. Thyroid ultrasonography helps to identify patients with diffuse lympho- cytic thyroiditis who are prone to develop hypothyroidism. J Clin Endocrinol Metab 1991;72:209-213
  15. Hayashi N. Sonography of Hashimoto’s thyroiditis. J Clin Ultrasound 1986;14:123-126
  16. Saleh A, Cohnen M, Fürst G, et al. Differential diag- nosis of hyperthyroidism: Doppler sonographic quantification of thyroid blood flow distinguishes between Graves’ disease and diffuse toxic goiter. Exp Clin Endocrinol Diabetes 2002;110:32-36
  17. Muller H W, Schroder S, Schneider C, et al. Sonographic tissue characte