Comparison of the accuracy of the cannulated pedicle screw and the classical pedicle screw in the treatment of Scheuermann’s kyphosis: A retrospective study

Pages
201–208
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Incorrect screw rate in group 1 was significantly lower than group 2; 21 (6.6%) and 53 (22.6%), respectively (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: This study aims to investigate if use of cannulated pedicle screw (CPS) in the dysplastic pedicles in Scheuermann’s kyphosis (SK) increases the accuracy rate of the screw and reduces screw-related complications.Patientsandmethods:This retrospective study included 21 patients (11 males, 10 females; mean age 19.1 years; range, 13 to 22 years) (550 screws) who received correction with pedicle screws due to SK deformity between May 2015 and January 2019.
📊
Key Findings & Data:Between 2017 and 2018, classical pedicle screws were used in addition to CPSs in the upper thoracic region (T2, T3, T4) and thin pedicles (group 1).
💡
Conclusion & Impact:Incorrect screw rate in group 1 was significantly lower than group 2; 21 (6.6%) and 53 (22.6%), respectively (p
🔬Design:Research Article
📍Scope:2015 Verileri
⚙️Variables:Domain Parameters

Abstract

Objectives: This study aims to investigate if use of cannulated pedicle screw (CPS) in the dysplastic pedicles in Scheuermann’s kyphosis (SK) increases the accuracy rate of the screw and reduces screw-related complications.Patientsandmethods:This retrospective study included 21 patients (11 males, 10 females; mean age 19.1 years; range, 13 to 22 years) (550 screws) who received correction with pedicle screws due to SK deformity between May 2015 and January 2019. Between 2017 and 2018, classical pedicle screws were used in addition to CPSs in the upper thoracic region (T2, T3, T4) and thin pedicles (group 1). However, during the years 2015 to 2016, only classical pedicle screws were used for the patients who underwent posterior instrumentation for SK (group 2). Computed tomography scanning was used to investigate the accuracy of the screws.Results: There were 12 patients (316 screws) in group 1 and nine patients (234 screws) in group 2. Seventy-four (13.4%) of all screws were inserted incorrectly. Incorrect screw rate in group 1 was significantly lower than group 2; 21 (6.6%) and 53 (22.6%), respectively (p

🔖

Cite This Article

TOY, S., YILAR, S., KÖSE, A., ZEYNAL, M., KÖSE, M. (2022). Comparison of the accuracy of the cannulated pedicle screw and the classical pedicle screw in the treatment of Scheuermann’s kyphosis: A retrospective study. Joint diseases and related surgery, Cilt: 31 - Sayı: 2, 201–208. https://ajindex.com/articles/559353

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Scheuermann HW. The classic: kyphosis dorsalis juvenilis. Clin Orthop Relat Res 1977;128:5-7
  2. Ali RM, Green DW, Patel TC. Scheuermann's kyphosis. Curr Opin Pediatr 1999;11:70-5
  3. Liljenqvist UR, Link TM, Halm HF. Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine (Phila Pa 1976) 2000;25:1247-53
  4. Zindrick MR, Knight GW, Sartori MJ, Carnevale TJ, Patwardhan AG, Lorenz MA. Pedicle morphology of the immature thoracolumbar spine. Spine (Phila Pa 1976) 2000;25:2726-35
  5. Yilar S. Comparison of the accuracy of cannulated pedicle screw versus conventional pedicle screw in the treatment of adolescent idiopathic scoliosis: A randomized retrospective study. Medicine (Baltimore) 2019;98:e14811
  6. Lee CK, Chan CYW, Gani SMA, Kwan MK. Accuracy of cannulated pedicle screw versus conventional pedicle screw for extra-pedicular screw placement in dysplastic pedicles without cancellous channel in adolescent idiopathic scoliosis: a computerized tomography (CT) analysis. Eur Spine J 2017;26:2951-60
  7. Atik OŞ. Which articles do we prefer to publish? Eklem Hastalik Cerrahisi 2018;29:1
  8. Rao G, Brodke DS, Rondina M, Bacchus K, Dailey AT. Inter- and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement. Spine (Phila Pa 1976) 2003;28:2527-30
  9. Cobden A, Albayrak A, Camurcu Y, Sofu H, Tacal T, Kaygusuz MA. Posterior-Only Approach with Pedicle Screws for the Correction of Scheuermann’s Kyphosis. Asian Spine J 2017;11:513-9
  10. Tsirikos AI, Jain AK. Scheuermann's kyphosis; current controversies. J Bone Joint Surg Br 2011;93:857-64
  11. Fujimori T, Iwasaki M, Nagamoto Y, Kashii M, Takao M, Sugiura T, et al. Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector. Clin Spine Surg 2017;30:E64-E75
  12. Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 2007;32:E56-64
  13. Kwan MK, Chiu CK, Gani SM, Wei CC. Accuracy and Safety of Pedicle Screw Placement in Adolescent Idiopathic Scoliosis Patients: A Review of 2020 Screws Using Computed Tomography Assessment. Spine (Phila Pa 1976) 2017;42:326-35
  14. Sarwahi V, Wendolowski SF, Gecelter RC, Amaral T, Lo Y, Wollowick AL, Thornhill B. Are We Underestimating the Significance of Pedicle Screw Misplacement? Spine (Phila Pa 1976) 2016;41:E5