Journals / İstanbul Üniversitesi Veteriner Fakültesi Dergisi / 2014 / Cilt: 41 - Sayı: 2

Transosseöz Osteosentez Altındaki Kemik Dokusunun Dansitometrik Parametrelerinin Aşırı Sert Bileşiklerle Kaplanmış Deneysel İmplantlar Kullanarak Karşılaştırmalı Çalışması

Pages
185–190
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This leads us to conclude that implants coated with titanium and hafnium nitrides are biologically and chemically inert because less pathologic changes in the bone tissue were observed, in contrast to the copper- based implants and those where the coating contains zirconium.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Abstract By X-ray computed tomography (CT), density characteristics of the tibiae bones in 25 experimental adult male rats were studied after their tibiae bones have experimentally fractured and then repaired by osteosynthesis using different implants.
📊
Key Findings & Data:At the same time, the densities of the tibiae in rats with implants made of copper and implants coated with a combination of titanium and zirconium nitrides were 1.5-2 times lower than those of the intact bones.
💡
Conclusion & Impact:This leads us to conclude that implants coated with titanium and hafnium nitrides are biologically and chemically inert because less pathologic changes in the bone tissue were observed, in contrast to the copper- based implants and those where the coating contains zirconium.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Abstract By X-ray computed tomography (CT), density characteristics of the tibiae bones in 25 experimental adult male rats were studied after their tibiae bones have experimentally fractured and then repaired by osteosynthesis using different implants. According to the data that was obtained by computed tomography, it has been defined that bone densities depend on the type of the implant and the chemical composition of the coating which is applied on the surface of the implant. Thus, average values of the density of the tibiae bones in the experimental rats with implants coated with a combination of titanium and hafnium nitrides were not different from the density values of the intact bones. At the same time, the densities of the tibiae in rats with implants made of copper and implants coated with a combination of titanium and zirconium nitrides were 1.5-2 times lower than those of the intact bones. This leads us to conclude that implants coated with titanium and hafnium nitrides are biologically and chemically inert because less pathologic changes in the bone tissue were observed, in contrast to the copper- based implants and those where the coating contains zirconium.

🔖

Cite This Article

SHAKIROVA, F., MANIRAMBONA, J. C., GATINA, E., KABIROV, G., AKHTIAMOV, I., ZAKIROV, R. (2022). Transosseöz Osteosentez Altındaki Kemik Dokusunun Dansitometrik Parametrelerinin Aşırı Sert Bileşiklerle Kaplanmış Deneysel İmplantlar Kullanarak Karşılaştırmalı Çalışması. İstanbul Üniversitesi Veteriner Fakültesi Dergisi, Cilt: 41 - Sayı: 2, 185–190. https://ajindex.com/articles/555133

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Abdullin, I.S., Mironov, M., Garipova, G.I., 2004. Germicidal and biologically resistant coatings for medical implants and instruments. Med Technology 4, 20-22.
  2. Akhtyamov, I.F., Gatina, E.B., Kadyrov, F.F., Shaehov, M.F., 2012. Study the interaction of a biocompatible coating of a mixture of metal nitrides of group IV with living tissues. Herald of Kazan Technological University 15 (20), 176 -179. Akhtyamov, I.F., Shakirova, F.V., Gatina, E.B., Zubairova, L.D., Aliyev, E.I. 2013. Evaluation of the acute phase in experimental osteosynthesis with implants coated with bioinert metal superhard nitrides. Genius Orthopedics Academician GA Ilizarov 4, 80-83.
  3. Akhtyamov, I.F., Shakirova, F.V., Gatina, E.B., Manirambona, J.C., 2014. Clinical study of impact of implants made of different types of metals on the physical state of the experimental animals. Genius Orthopedii Moscow 4, 36-43.
  4. Amstutz, H.C., Campbell, P., Kossovsky, N., Clarke, I.C., 1992. Mechanism and clinical significance of wear debris induced osteolysis. Clinical Orthopaedics and Related Research 276, 7-18.
  5. Brandes, E.A., Brook, G.B., 1992. Smithells Metals Reference Book. 7th ed. Oxford, Butterworth-Heinemann. pp. 26- 32. Cooke, F.W., 1992. Ceramics in orthopedic surgery. Clinical Orthopaedics and Related Research 276, 135-146.
  6. Davidson, J.A., 1993. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. Clinical Orthopaedics and Related Research 294, 361-378.
  7. Dyachkova, G.V., Diachkov, K.A., Aleksandrov, S.M., Larionov, T.A., Klyushin, N.M., 2013. Assessment of bone quality by computed tomography in patients with chronic osteomyelitis. Journal Traumatology and Orthopaedics 3, 88-95.
  8. Dyachkova, G.V., Mitin, Y.L., 2011. Semiotics of proliferative changes in the femur chronic osteomyelitis that developed after acute osteomyelitis. Journal of Traumatology and Orthopedics 4, 60-64.
  9. Edelson, J.G., 1984. Congenital dislocation and computerized axial tomography. Journal of Bone and Joint Surgery, 66 (4), 472-478.
  10. Hermawan, H., Mantovani, D., 2009. Degradable metallic biomaterials: The concept, current developments and future directions. Minerva Biotecnologica 21, 207-216.
  11. Horowitz, S.M., Purdon, M.A., 1995. Mechanisms of cellular recruitment inaseptic loosening of prosthetic joint implants. Calcified Tissue International 57, 301-305.
  12. Lewis, N., Nelson, L., Lewin, N., Howland, M.A., Hoffman,Goldfrank, L., Flomenbaum, N., 200