Journals / İstanbul Ticaret Üniversitesi Fen Bilimleri Dergisi / 2022 / Cilt: 21 - Sayı: 41

STUDYING THE ELECTROCHEMICAL BEHAVIORS OF ANODIZED METALLIC IMPLANTS FOR IMPROVED CORROSION RESISTANCE

GELİŞMİŞ KOROZYON DİRENCİ İÇİN ELOKSALLI METALİK İMPLANTLARIN ELEKTROKİMYASAL DAVRANIŞLARININ İNCELENMESİ

Pages
117–135
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Also, as a result of anodization, the natural oxide layer was observed on the material surface, thus the corrosion rate is reduced and the life of the biomaterial has been improved.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A study about long-term corrosion behavior of anodized and non-anodized Ti6Al4V and MgAZ31B biomaterials was conducted under controlled conditions.
📊
Key Findings & Data:By applying 20V DC potential, MgAZ31B alloys was anodized in phosphoric acid and potassium hydroxide while Ti6Al4V alloys was anodized in phosphoric acid and oxalic acid.
💡
Conclusion & Impact:Also, as a result of anodization, the natural oxide layer was observed on the material surface, thus the corrosion rate is reduced and the life of the biomaterial has been improved.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Anotlama · Elektrokimyasal Davranış · Korozyon

Abstract

A study about long-term corrosion behavior of anodized and non-anodized Ti6Al4V and MgAZ31B biomaterials was conducted under controlled conditions. By applying 20V DC potential, MgAZ31B alloys was anodized in phosphoric acid and potassium hydroxide while Ti6Al4V alloys was anodized in phosphoric acid and oxalic acid. Long-term experiments were carried out by immersing them in deionized (DI) water, 3% NaCl and phosphate-buffered saline (PBS) solutions. The corrosion rate and pattern were measured by electrochemical analysis. Also, as a result of anodization, the natural oxide layer was observed on the material surface, thus the corrosion rate is reduced and the life of the biomaterial has been improved.

Özet

Eloksallı ve anodize edilmemiş Ti6Al4V ve Mg AZ31B biyomalzemelerinin korozyon davranışına ilişkin uzun vadeli bir araştırma, kontrollü koşullar altında gerçekleştirilmiştir. Ti6Al4V fosforik asit ve oksalik asit içinde anodize edilirken, Mg AZ31B fosforik asit ve potasyum hidroksit içinde 20V DC potansiyel uygulanarak anodize edilmiştir. %3 NaCl, fosfat tamponlu salin (PBS) ve deiyonize (DI) su çözeltilerine daldırılarak uzun süreli deneyler yapıldı. Korozyon hızı ve deseni elektrokimyasal analiz ile ölçülmüş ve anotlamanın malzeme yüzeyindeki doğal oksit tabakasını arttırdığı, korozyon hızını azalttığı ve biyomalzemenin ömrünü uzattığı gözlemlenmiştir.

🔖

Cite This Article

MURAD, M. S., USTA, A., ASMATULU, R., CEYLAN, M. (2022). STUDYING THE ELECTROCHEMICAL BEHAVIORS OF ANODIZED METALLIC IMPLANTS FOR IMPROVED CORROSION RESISTANCE. İstanbul Ticaret Üniversitesi Fen Bilimleri Dergisi, Cilt: 21 - Sayı: 41, 117–135. https://ajindex.com/articles/552754

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Ahmad, Z. (2006). Principles of corrosion engineering and corrosion control. Elsevier. Bandeira, R. M., Rêgo, G. C., Picone, C. A., van Drunen, J., Correr, W. R., et al. (2020). Alternating current oxidation of Ti–6Al–4V alloy in oxalic acid for corrosion-resistant surface finishing. SN Applied Sciences, 2(6), 1-14.
  2. Barril, S., Debaud, N., Mischler, S. & Landolt, D. (2002). A tribo-electrochemical apparatus for in vitro investigation of fretting–corrosion of metallic implant materials. Wear, 252(9-10), 744-754.
  3. Bidhendi, H.R.A. & Pouranvari, M. (2012). Corrosion study of metallic biomaterials in simulated body fluid. Metallurgical and Materials Engineering, 17(1), 13-22.
  4. Biesiekierski, A. Wang, J., Gepreel, M. A. H., & Wen, C. (2012). A new look at biomedical Ti-based shape memory alloys. Acta Biomaterialia, 8(5), 1661-1669.
  5. Burnat, B. Walkowiak-Przybyło, M., Błaszczyk, T., & Klimek, L. (2013). Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution. Acta of Bioengineering and Biomechanics, 15(1), 87-95.
  6. Callister, W. D. & Rethwisch, D. G. (2007). Materials science and engineering: an introduction 7, 665-715. John Wiley & Sons, New York. Chatterjee, S. (2022). Titanate incorporated anodized coating on magnesium alloy for corrosion protection, antibacterial responses and osteogenic enhancement. Journal of Magnesium and Alloys, 10(4), 1109-1123.
  7. De Oliveira, L.A. & Antunes, R. A. (2018). Influence of the electrolyte composition on the corrosion behavior of anodized AZ31B magnesium alloy. Metals - Open Access Metallurgy Journal, 11(10), 1573. De Viteri, V.S. & Fuentes, E. (2013). Titanium and titanium alloys as biomaterials. Tribology-fundamentals and advancements, 5, 154-181.
  8. Estrada-Cabrera, E., Torres-Ferrer, L. R., Aztatzi-Aguilar, O. G., De Vizcaya-Ruiz, A., Meraz-Rios, M. A., et al. (2019). Chitosan-bioglass coatings on partially nanostructured anodized Ti-6Al-4V alloy for biomedical applications. Surface and Coatings Technology, 375, 468-476.
  9. Fattah-Alhosseini, A. & Joni, M. S. (2015). Effect of KOH Concentration on the Microstructure and Electrochemical Properties of MAO-Coated Mg Alloy AZ31B. Journal of Materials Engineering and Performance, 24(9), 3444-3452.
  10. Feng, A. & Han, Y. (2010). The microstructure, mechanical and corrosion properties of calcium polyphosphate reinforced ZK60A magnesium alloy composites. Journal of Alloys and Compounds, 504(2), 585-593.
  11. Ferreira, M. E., de Lourdes Pereira, M., e Costa, F. G., Sousa, J. P.