Journals / Istanbul University Journal of Electrical and Electronics Engineering / 2009 / Cilt: 9 - Sayı: 1

Flashover disharge on a new model of polluted insulators

Pages
819–825
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

A comparison with the case of point to point gap reveals that the electric field in the air in the vicinity of the electrolyte surface is the responsible of the discharge elongation, and the critical conditions of flashover are the weakest initial electric conditions necessary to create this field distribution.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this paper we present an experimental work on a new laboratory model for flashover studies.
📊
Key Findings & Data:Twosurfaces polluted disk insulator model, This model looks like a real outdoor insulator with respecting its shape and pollution.
💡
Conclusion & Impact:A comparison with the case of point to point gap reveals that the electric field in the air in the vicinity of the electrolyte surface is the responsible of the discharge elongation, and the critical conditions of flashover are the weakest initial electric conditions necessary to create this field distribution.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this paper we present an experimental work on a new laboratory model for flashover studies. Twosurfaces polluted disk insulator model, This model looks like a real outdoor insulator with respecting its shape and pollution. The experimental results of this model and their analysis were performed in two groups: The first is the measure of pollution resistance between the ground electrode and a static discharge for many discharge positions; the second is the measure of critical current and critical voltage according to the position of the discharge starting point. A comparison with the case of point to point gap reveals that the electric field in the air in the vicinity of the electrolyte surface is the responsible of the discharge elongation, and the critical conditions of flashover are the weakest initial electric conditions necessary to create this field distribution.

🔖

Cite This Article

HAMOUDA, M., FLAZI, S. (2022). Flashover disharge on a new model of polluted insulators. Istanbul University Journal of Electrical and Electronics Engineering, Cilt: 9 - Sayı: 1, 819–825. https://ajindex.com/articles/543758

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Obenaus F., “Die uberschlagspannung verschmutzter isolatoren’’ ETZ, Vol:56, (1935), pp. 369-370. [2] abadi J.C., “Etude de la validité du modèle électrique du contournement des isolateurs haute tension pollués” Thèse de spécialité. Université Paul Sabatier Toulouse, 1971
  2. Matsuo Tsuo H., Yamashita T. Shi W.D., “Electrical contact between a local discharge on an electrolyte solution and the solution surface”, IEEE Trans. On Dielectric and Elect. Insul., Vol: 7 (2000), pp. 360-365
  3. Hampton B.F., “ Flasheover mechanisme of polluted insulation ” Proc IEE, Vol: III, No. 5, pp. 985-90, 8 May, 1964
  4. Wilkins R., “Flashover voltage of high voltage insulators with uniform surface pollution films” Proc. IEE, Vol: 116, No. 3, March, 1969, pp. 457-65
  5. Rahal A.M., “Sur les mécanismes physiques du contournement des isolateurs H.T”. Thèse de docteur es-sciences physiques. Université Paul Sabatier Toulouse, 1979
  6. Flazi S., “Etude du contournement électrique des isolateurs haute tension pollues critère d’élongation de la décharge et dynamique du phénomène”, Thèse de docteur d’état science. Université Paul Sabatier, Toulouse, 1987
  7. Benchaîb K., “Etude des conditions favorables du contournement des isolateurs haute tension pollués”, PFE, université USTO Oran, 1985 [9] Boudjella A., “Etude de l’èvolution d’une décharge vers le contournement d’un isolateur HT simulé par un modèle à plusieurs films de pollution”, Thèse de magister. Université USTO, Oran, 1986
  8. Boudjella A., Hadi H., Flazi S., Yumoto M., Sakai T., Hosokawa T., “Study of the discharge propagation direction on two electrolyte water channels (part 2)” GD’97, Germany
  9. Flazi S., “Etude critique des critères du contournement”, CNHT’2002 Ghardaia, 16-17 Janvier, 2002
  10. Flazi S., Hadi H., Rabah K.L., Hamouda M., Boudjella A., “Dynamique aspect of the direct current flashover on rectangular and new disk models”, IEEE CEIDP’2001, Kitchener, On, Canada, Oct. 14-17, 2001
  11. Flazi S., Hamouda M., “Influence of the electric field to the neighbourhood of the discharge on its propagation to flashover”, ELECO’99, Turkey.