Details of the control strategy and system simulation results in Simulink are presented in the paper to show the effectiveness of the proposed control strategy.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Variable speed wind turbines (WT) based on the Doubly-Fed Induction Generator (DFIG) is commercially offered and is frequently used in grid connected mode.
📊
Key Findings & Data:Below rated wind speed, tracking the maximum power/torque curve realized by speed/current control mode while pitch control ensures the rated power for above rated wind speed.
💡
Conclusion & Impact:Details of the control strategy and system simulation results in Simulink are presented in the paper to show the effectiveness of the proposed control strategy.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Variable speed wind turbines (WT) based on the Doubly-Fed Induction Generator (DFIG) is commercially offered and is frequently used in grid connected mode. The variable speed operation in such wind turbines is achieved by means of a four-quadrant ac-dc-ac power converter among the rotor winding and the grid while the stator is directly connected to the grid. Below rated wind speed, tracking the maximum power/torque curve realized by speed/current control mode while pitch control ensures the rated power for above rated wind speed. In this research, a maximum power control strategy is incorporated with the DFIG whereby the produced power serves as the dynamic active power reference for the DFIG. Stator flux oriented vector control is applied to decouple the control of active and reactive power generated by the DFIG based WT. Details of the control strategy and system simulation results in Simulink are presented in the paper to show the effectiveness of the proposed control strategy.

🔖

Cite This Article

ARIFUJJAMAN, M., IQBAL, M., QUAICOE, J. E. (2022). Vector control of a DFIG based wind turbine. Istanbul University Journal of Electrical and Electronics Engineering, Cilt: 9 - Sayı: 2, 1057–1066. https://ajindex.com/articles/543749

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Zhao, Y., Zou, X.D., Xu, Y.N., Kang, Y., Chen, J. “Maximal Power Point Tracking under Speed-Mode Control for Wind Energy Generation System with Doubly Fed Introduction Generator,” Proceedings of the IEEE International Power Electronics and Motion Control Conference 2006, Shanghai; China, Vol: 1, pp.1 – 5, 2006 [2] Cardenas, Roberto., Pena, Ruben., “Sensorless Vector Control of Induction Machines for Variable-Speed Wind Energy Applications,” IEEE Transaction on Energy Conversion, Vol: 19, No: 1, pp. 196 – 205, 2004. [3] Li, H., Chen, Z., Pedersen J.K., “Optimal Power Control Strategy of Maximizing Wind Energy Tracking and Conversion for VSCF Doubly Fed Induction Generator System,” Proceedings of the IEEE International Power Electronics and Motion Control Conference 2006, Shanghai; China, Vol: 3, pp.1 – 6.2006 [4] Senjyu, T., Sakamoto, R., Urasaki, N., Funabashi, T., Fujita, H., Sekine, H., “Output power leveling of wind turbine Generator for all operating regions by pitch angle control,” IEEE Transaction on Energy Conversion, Vol: 21, No: 2, pp. 467 – 475, 2006. [5] Mohamed, M.B., Jemli, M., Gossa, M., Jemli, K., “Doubly fed induction generator (DFIG) in wind turbine modeling and power flow control,” Proceedings of the IEEE International Conference on Industrial Technology 2004, AL; USA, Vol: 2, pp. 580-584, 2004 [6] Siegfried, Heier. “Grid Integration of Wind Energy Conversion Systems,” John Wiley & Sons Ltd, 1998, ISBN 0-471-97143-X [7] He, Yikang., Hu, Jiabing, Zhao, Rende. “Modeling and control of wind-turbine used DFIG under network fault conditions,” Proceedings of the International Conference on Electrical Machines and Systems 2005,
  2. China, Vol: 2, pp. 986-991, 2005 [8] Holdsworth, L., Wu, X.G., Ekanayake, J.B., Jenkins, N., “Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances,” Proceedings of the IEE Generation, Transmission and Distribution, Vol: 150, Issue 3, pp.343 – 352, 2003 [9] Toufik, B., Machmoum, M., Poitiers, F., “Doubly fed induction generator with active filtering function for wind energy conversion system,” Proceedings of the European Conference on Power Electronics and Applications 2005, Dresden; Germany, pp. 1-9, 2005