The experimental resultsare illustrated in graph diagrams and results showed that the presented method is very effective andeasy to use for prognosis of static eccentricity fault.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper presents an experimental study on diagnosis of eccentricity fault in permanent magnetsynchronous motor (PMSM).
📊
Key Findings & Data:In addition, performanceof the motor over the period of starting up to the steady state is investigated.
💡
Conclusion & Impact:The experimental resultsare illustrated in graph diagrams and results showed that the presented method is very effective andeasy to use for prognosis of static eccentricity fault.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

This paper presents an experimental study on diagnosis of eccentricity fault in permanent magnetsynchronous motor (PMSM). The study carried out by analyzing the harmonics obtained using PowerSpectral Density (PSD) of stator current and voltage at no load condition. Motor stator current andvoltage are uploaded to pc with software of used inverter and their harmonics obtained by usingLabVIEW Signal Express Toolbox program for healthy and faulty condition. In addition, performanceof the motor over the period of starting up to the steady state is investigated. The experimental resultsare illustrated in graph diagrams and results showed that the presented method is very effective andeasy to use for prognosis of static eccentricity fault.

🔖

Cite This Article

AKAR, M., ÇANKAYA, İ. (2022). Diagnosis of static eccentricity fault in permanent magnet synchronous motor by on-line monitoring of motor current and voltage. Istanbul University Journal of Electrical and Electronics Engineering, Cilt: 9 - Sayı: 2, 959–967. https://ajindex.com/articles/543724

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Öztürk, S., Low-Cost Direct Torque Control of Permanent Magnet Synchronous Motors Using Hall-Effect Sensors, M.S. Thesis, Texas A&M University, College Station, TX, December 2005. [2] www.siemens.com.tr [3] Yeh C,. Sayed-A, Povinelli R., “A Reconfigurable Motor for Experimental Emulation of Stator Winding Inter-Turn and Broken Bar Faults in Polyphase Induction Machines”, IEEE Transactions on Energy Conversion, Vol. 23, No. 4, pp. 1005-1014, Dec.2008
  2. Rosero J., Cusido J., Garcia A., Ortega J., and Romeral L., “Broken Bearings and Eccentricity Fault Detection for a Permanent Magnet Synchronous Motor”,The 32nd Annual Conference of the IEEE Industrial Electronics Society, Paris - FRANCE, pp. 964-969, 2006
  3. Kral C., “Detection of Mechanical Imbalances of Induction Machines Without Spectral Analysis of Time- Domain Signals”, IEEE Transactions on Industry Applications, Vol. 40, No. 4, pp. 1101-1106, Aug. 2004
  4. Haylock J., Mecrow B., Jack A., and Atkinson D., “Operation of Fault Tolerant PM Drive for an Aerospace Fuel Pump Application”, IEE Proceedings Electric Power Applications, Vol. 145,No. 5, pp. 441-448, Sept. 1998
  5. Vas P., Parameter Estimation, Condition Monitoring, and Diagnosis of Electrical Machines, Clarendron Press, Oxford, 1993
  6. Nandi S., Toliyat H.A., and Li X., “Condition Monitoring and Fault Diagnosis of Electrical Machines-A Review,” IEEE Transactions on Energy Conversion, Vol. 20, No. 4, pp. 719-729, Dec. 2005
  7. Rosero J., Cusido J., Garcia A., Ortega J., and Romeral L., “On-line Condition Monitoring Technique for PMSM Operating with Eccentricity”, The 6th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, IEEE SDEMPED, Cracow, Poland, 2007
  8. Mahdi B. E., Faiz J, Roshtkhari M, and Zargham N. A., “Static Eccentricity Fault Diagnosis in Permanent Magnet Synchronous Motor Using Time Stepping Finite Element Method”, IEEE Transactions on Magnetics, Vol. 44, No. 11, pp. 4297-4300, Nov. 2008
  9. Çankaya I., Vatansever F., “Fourier ve Dalgacık Dönüşümünün Karsılaştırılması”, Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt 6, Sayı 3, ss.9-13, 2002 (In Turkish)
  10. Steven W. Smith, The Scientist and Engineer's Guide to Digital Signal Processing, California Technical Publishing, 1997
  11. Krikor K. S., Numan H. A., “On-Line Current-Based Condition Monitoring and Fault Diagnosis of Three-Phase Induction Motor”, Eng. &Technology, Vol. 25, No. 3, pp. 395-406,