Journals / Istanbul University Journal of Electrical and Electronics Engineering / 2003 / Cilt: 3 - Sayı: 2

The effect of environmental factors on the performance of polyester outdoor insulators

Pages
943–953
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

UV radiation and wind pressure caused carbonised tracking patterns with wide branches around the high voltage electrode.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Surface tracking is one of the severe degradation mechanisms observed on polymeric insulators.
📊
Key Findings & Data:In this study, by using the ASTM D 2303 Inclined Plane Tracking Test method the effects of Mechanical effect(compressive stress and tensile stress), ultraviolet (UV) radiation and wind pressure from different positions with respect to the surface of the sample under test have been investigated in detail.
💡
Conclusion & Impact:UV radiation and wind pressure caused carbonised tracking patterns with wide branches around the high voltage electrode.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Surface tracking is one of the severe degradation mechanisms observed on polymeric insulators. There are too many factors associated with the degradation process, hence it is not easy to make an estimate about the useful service life of an insulator. However it is possible to reduce the variability observed in the tracking initiation times and tracking patterns by testing the samples in laboratory under predefined conditions. In this study, by using the ASTM D 2303 Inclined Plane Tracking Test method the effects of Mechanical effect(compressive stress and tensile stress), ultraviolet (UV) radiation and wind pressure from different positions with respect to the surface of the sample under test have been investigated in detail. All samples have been prepared by using polyester without any accelarator. In all cases tracking initiation times were reduced significantly depending on the external conditions. UV radiation and wind pressure caused carbonised tracking patterns with wide branches around the high voltage electrode.

🔖

Cite This Article

UĞUR, M., MEREV, A., KUNTMAN, A. (2022). The effect of environmental factors on the performance of polyester outdoor insulators. Istanbul University Journal of Electrical and Electronics Engineering, Cilt: 3 - Sayı: 2, 943–953. https://ajindex.com/articles/542487

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. D. P. Augood, ‘Dielectric Aging – Overview and Comment’, Proceedings of 1978 IEEE International Symposium on EL, pp. 17-21, 1978
  2. H. R. Zeller, ‘Breakdown and Prebreakdown phenomena in solid Dielectrics’, Proceedings of 2nd International Conference on Conduction and breakdown in Solid Dielectrics, pp.98-109, 1986
  3. L. Simoni, G. Mazzanti, and G. C. Montanari, ‘Life Model for Insulating Matarials in Combined-stress Condition’, Proceeding of 1994 ICPADM Conference, pp. 827-832, 1994
  4. T. W. Dakin, ‘Electrical Insulation Deterioration’, Electrotechnology, Vol.3, pp129- 130, 1960
  5. P. Crine, J. L. Parpal and C. Dang, ‘A New Approach to the Electric Aging of Dielectrics’, Proceedings of 1989 Conference on Electrical Insulation and Dielectric Phenomena, pp. 161-167, 1989
  6. P. Crine, ‘Applications of the Rate Theory to the Understanding of Various Dielectric Aging Mechanisms’, Proceedings of the Workshop on Multifactor Aging Mechanisms and Models, CEIDP92, Victoria, 1992
  7. G. C. Montanari and L. Simoni, ‘Aging Phenomenology and Modeling’, IEEE Transactions on El, Vol.28, pp.755-776, 1993
  8. R. Houlgate, ‘Outdoor Testing of non Ceramic Insulators’, IEE Colloquium on a Review of Outdoor Insulation Materials, pp.8.1-8.4, 1996
  9. B. Jubb, ‘Current overseas practice wirh transmission at 132kV and above’, IEE Colloquium on a review of outdoor insulation materials, pp 1.1-1.6, 1996
  10. M. Uğur, B. R. Varlow, ‘Analysing and Modelling the 2D surface tracking patterns of polymeric insulation materials’, IEEE Transactions on Dielectrics and Electrical Insulation, Vol 5, No 6, pp 824-828, 1998
  11. A. Kuntman, T.Yılmaz, A. Güngör, B.M. Baysal, ‘A New Polyimide Film for VLSI and its Electrical Characterization’, IEEE Transactions on Dielectrics and Electrical Insulation, Vol.5, pp296-300, 1998
  12. R.Gorur, J.Montesinos, L.Varadadesikan, S.Simmons, M.Shah, ‘A rapid test method for evaluating the tracking and erosion resistance of polymeric outdoor insulating materials’, CEIDP, pp.402-405, 1997
  13. Crine, and A. K. Vijh, ‘A Molecular Approach to the Physicochemical Factors in the Electrical Breakdown of Polymers’, Applied Physics Communications, Vol.5, pp. 139-163, 1985
  14. H. J. Wintle, ‘Conduction Processes in Polymers’, in Engineering Dielectrics, Vol. IIA, R. Bartnikasand R. M. Eichhorn,Editors, pp. 239-354, ASTMSpecial Technical Publication 763, 1983
  15. C. C. Ku and R. Liepins, ‘Electrical Properties of polymers’, Hanser Publishers, M