Journals / International Journal of Pure and Applied Sciences / 2021 / Cilt: 7 - Sayı: 1

Voltammetric Detection of Levodopa and Benserazide at Polypyrrole and Single Walled Carbon Nanotube Based Electrode

Pages
207–218
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Eventually, very satisfactory results in terms of analytical performance and applicability have been achieved with the designed electrode.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, it was aimed to use pyrrole monomer and single-walled carbon nanotube (SWCNT) in the production of modified electrodes, and to examine the electrochemical properties of these electrodes.
📊
Key Findings & Data:The developed modified electrode gave linear responses with DPV technique in concentration ranges of 10 - 50 μM for LD and 10 - 50 μM for BS.
💡
Conclusion & Impact:Eventually, very satisfactory results in terms of analytical performance and applicability have been achieved with the designed electrode.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Electropolymerization · Parkinson · polypyrrole

Abstract

In this study, it was aimed to use pyrrole monomer and single-walled carbon nanotube (SWCNT) in the production of modified electrodes, and to examine the electrochemical properties of these electrodes. Bulk electrolysis technique was used for growing polypyrrole. The applicability of the polypyrrole and SWCNT-based electrodes was tested by electrochemically detecting active substances such as levodopa (LD) and benserazide (BS) used in the treatment of Parkinson's disease. During the design and analysis phase of the modified electrode, many electroanalytical optimization and validation parameters were examined. The developed modified electrode gave linear responses with DPV technique in concentration ranges of 10 - 50 μM for LD and 10 - 50 μM for BS. In addition, limits of detection in these wide linear ranges were obtained as very low. Limits of detection were calculated as 2.4 μM and 1.2 μM for LD and BS, respectively. In addition, the applicability of the designed electrode and method was tested in urine and drug samples. The selectivity of this electrode was carried out in placebo solutions containing the interfering species. It is advantageous that the drug active ingredients are easily, selectively and quickly determined at this modified electrode in the presence of components that affect the analysis. Eventually, very satisfactory results in terms of analytical performance and applicability have been achieved with the designed electrode.

🔖

Cite This Article

SAVAN, E. K., ERDOĞDU, G. (2022). Voltammetric Detection of Levodopa and Benserazide at Polypyrrole and Single Walled Carbon Nanotube Based Electrode. International Journal of Pure and Applied Sciences, Cilt: 7 - Sayı: 1, 207–218. https://ajindex.com/articles/541545

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Adamiak-Giera, U., Gawronska-Szklarz, B., 2018. Simultaneous Determination of Levodopa and 3-O-Methyldopa in Patients with Parkinson’s Disease by High-Performance Liquid Chromatography with Electrochemical Detection. Journal of Liquid Chromatography and Related Technologies, 41(19–20):1047–51.
  2. Adamiak-Giera, U., Gawronska-Szklarz, B., 2018. Simultaneous Determination of Levodopa and 3-O-Methyldopa in Patients with Parkinson’s Disease by High-Performance Liquid Chromatography with Electrochemical Detection. Journal of Liquid Chromatography and Related Technologies, 41(19–20):1047–51.
  3. Aviles-Olmos, I., Martinez-Fernandez, R., Foltynie, T., 2010. L-dopa-Induced Dyskinesias in Parkinson’s Disease. European Neurological Journal, 2:2. Chen, C., Hutchison, J.E., Postlethwaite, T.A., Richardson, J.N., Murray, R.W., 1994. Chemically Modified Electrodes by Nucleophilic Substitution of Chlorosilylated Platinum Oxide Surfaces. Langmuir, 10(9):3332–37.
  4. Fabbrini, G., Brotchie, J.M., Grandas, F., Nomoto, M., Goetz, C.G., 2007. Levodopa-Induced Dyskinesias. Movement Disorders, 22(10):1379–89.
  5. He, W.W., Zhou, X.W., Lu, J.Q., 2006. Simultaneous Determination of Benserazide and Levodopa by Capillary Electrophoresis-Chemiluminescence Using an Improved Interface. Journal of Chromatography A, 1131(1–2):289–92.
  6. Jalalvand, A.R., 2020. Four-Dimensional Voltammetry: An Efficient Strategy for Simultaneous Determination of Ascorbic Acid and Uric Acid in the Presence of Dopamine as Uncalibrated Interference. Sensing and Bio-Sensing Research, 28:100330. Kobayashi, K., 2001. Role of Catecholamine Signaling in Brain and Nervous System Functions: New Insights from Mouse Molecular Genetic Study. Journal of Investigative Dermatology Symposium Proceedings, 6(1):115–21.
  7. Kuyumcu Savan, E. 2019a. Electrochemical Determination of N-Acetyl Cysteine in the Presence of Acetaminophen at Multi-Walled Carbon Nanotubes and Nafion Modified Sensor. Sensors and Actuators, B: Chemical, 282:500–506.
  8. Kuyumcu Savan, E., 2019b. Square Wave Voltammetric (SWV) Determination of Quercetin in Tea Samples at a Single-Walled Carbon Nanotube (SWCNT) Modified Glassy Carbon Electrode (GCE). Analytical Letters, 0(0):1–15.
  9. Kuyumcu Savan, E., Erdoğdu, G., 2020. Pirol ve Çok Duvarlı Karbon Nanotüp Modi̇fi̇ye Sensör ile Levodopa ve Benserazi̇di̇n Elektroki̇myasal Olarak Eşzamanlı Tayi̇ni̇. İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi, 8(2):336–55.
  10. Lechin, F., Van Der Dijs, B., Lechin, A.E., 2005. Circulat