Journals / International Journal of Intelligent Systems and Applications in Engineering / 2021 / Cilt: 9 - Sayı: 4

A Novel Hybrid Model for Automated Analysis Of Cardiotocograms Using Machine Learning Algorithms

Pages
266–272
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result of this hybrid model, 100% success was achieved for classification, test success, Accuracy, Sensitivity and Specificity with NB and DT ML algorithms.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a new hybrid model was presented for the prediction of fetal state from fetal heart rate (FHR) and the uterine contraction (UC) signals obtained from cardiotocogram (CTG) recordings.
📊
Key Findings & Data:In this study, due to the importance of this subject, a new hybrid model was developed which can perform high rate accurate diagnosis using Machine Learning (ML) algorithms.
💡
Conclusion & Impact:As a result of this hybrid model, 100% success was achieved for classification, test success, Accuracy, Sensitivity and Specificity with NB and DT ML algorithms.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, a new hybrid model was presented for the prediction of fetal state from fetal heart rate (FHR) and the uterine contraction (UC) signals obtained from cardiotocogram (CTG) recordings. CTG monitoring of FHR and uterine contractions during pregnancy and delivery provides information on the physiological status of the fetus to identify hypoxia. The precise information obtained from these records provides some ideas for interpreting the pathological condition of the fetus. Thus, with early intervention, it allows to prevent any negative situation that will occur in the fetus in the future. In this study, due to the importance of this subject, a new hybrid model was developed which can perform high rate accurate diagnosis using Machine Learning (ML) algorithms. In the hybrid model, 4 different ML algorithms (k Nearest Neighbors (k-NN), Decision Tree (DT), Naive Bayes (NB) and Support Vector Machine (SVM)) were used. While the diagnosis without the hybrid model was low, the improved hybrid model increased the accuracy by 34%. As a result of this hybrid model, 100% success was achieved for classification, test success, Accuracy, Sensitivity and Specificity with NB and DT ML algorithms.

🔖

Cite This Article

AVUÇLU, E. (2022). A Novel Hybrid Model for Automated Analysis Of Cardiotocograms Using Machine Learning Algorithms. International Journal of Intelligent Systems and Applications in Engineering, Cilt: 9 - Sayı: 4, 266–272. https://ajindex.com/articles/541285

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Tekin gündüz, S., kurtuldu, A., & Türkkan, I. Ş. I. K. (2017). Sağlık Hizmetlerinde Eşitsizlik ve Etik. Aksaray Üniversitesi İktisadi ve İdari Bilimler Fakültesi Dergisi, 8(4), 32-43
  2. Zach, L., Chudáček, V., Kužílek, J., Spilka, J., Huptych, M., Burša, M., & Lhotská, L. (2011). Mobile CTG—Fetal heart rate assessment using Android platform. In Computing in Cardiology (pp. 249-252). IEEE
  3. Andersson, S. U. S. A. N. N. E. (2011). Acceleration and deceleration detection and baseline estimation. Göteborg: Chalmers University of Technology
  4. UnbornHeart, http://www.unbornheart.com/, Accessed Date:14.5.2018
  5. A. Pinas and E. Chandraharan, (2016). Continuous cardiotocography during labour: Analysis, classification and management, Best Practice & Research Clinical Obstetrics & Gynaecology, vol. 30, pp. 33-47
  6. D. Ayres-de-Campos, C. Y. Spong, E. (2015). Chandraharan, and F. I. F. M. E. C. Panel, FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography, Int J Gynaecol Obstet, vol. 131, pp. 13-24
  7. J. Spilka, V. Chudáček, M. Koucký, L. Lhotská, M. Huptych, P. Janků, et al., (2012). Using nonlinear features for fetal heart rate classification, Biomedical Signal Processing and Control, vol. 7, pp. 350-357
  8. R. Czabanski, M. Jezewski, K. Horoba, J. Jezewski, and J. Leski, (2016). Fuzzy Analysis of Delivery Outcome Attributes for Improving the Automated Fetal State Assessment, Applied Artificial Intelligence, vol. 30, pp. 556-571
  9. H. Sahin and A. Subasi, (2015). Classification of the cardiotocogram data for anticipation of fetal risks using machine learning techniques, Applied Soft Computing, vol. 33, pp. 231-238
  10. M. Romano, P. Bifulco, M. Ruffo, G. Improta, F. Clemente, M. Cesarelli, (2016). Software for computerised analysis of cardiotocographic traces, Comput. Methods Programs Biomed., 124, pp. 121-137
  11. J. Kessler, D. Moster, S. Albrechfsen, (2014). Delay in intervention increases neonatal morbidity in births monitored with Cardiotocography and ST-waveform analysis, Acta Obs. Gynecol. Scand., 93 (2), pp. 175-181
  12. P.A. Warrick, E.F. Hamilton, D. Precup, R.E. Kearney, (2010). Classification of normal and hypoxic fetuses from systems modeling of intrapartum cardiotocography, IEEE Trans. Biomed. Eng., 57 (4), pp. 771-779
  13. A. Pinas, E. Chadraharan, (2016). Continuous Cardiotocography during labour: analysis, classification and management, Best. Pract. Res. Clin. Obstet. Gynaecol., 30, pp. 33-47