Journals / International Dental Research / 2019 / Cilt: 9 - Sayı: 3

Retention force of zirconia bar retained implant overdenture: Clinical comparative study between PEEK and plastic clips

Pages
92–98
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Within groupcomparison of mean retention values at different follow-up periodsrevealed significant difference for both groups.Conclusions: Within parameters of this study, it could be concludedthat both POM and PEEK retentive clips can provide acceptable andcomparable retention forces when used with zirconia bar during 12months period of overdenture use.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: This study aimed to evaluate and compare retention force of twoimplants retained mandibular overdenture with zirconia bar using twodifferent clip materials.Methodology: 20 completely edentulous patients (8 women and 12men) with age ranged between 45 and 65 years were selected for thisstudy.
📊
Key Findings & Data:Patients were randomlydivided into two equal groups where poly-oxy-methylene (POM) clip wasused for Group I and poly-ether-ether-ketone (PEEK) clip for Group II.Retention force was measured at time of overdenture insertion (T0), sixmonths (T6), and twelve months (T12) later.Results: Significant difference was recorded between the two groups ininitial retention forces (T0) where PEEK clip group recorded higherretention forces in comparison to POM clip group (P=0.029).
💡
Conclusion & Impact:Within groupcomparison of mean retention values at different follow-up periodsrevealed significant difference for both groups.Conclusions: Within parameters of this study, it could be concludedthat both POM and PEEK retentive clips can provide acceptable andcomparable retention forces when used with zirconia bar during 12months period of overdenture use.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: This study aimed to evaluate and compare retention force of twoimplants retained mandibular overdenture with zirconia bar using twodifferent clip materials.Methodology: 20 completely edentulous patients (8 women and 12men) with age ranged between 45 and 65 years were selected for thisstudy. All patients received conventional maxillary and mandibularcomplete dentures. Two implants were inserted bilaterally in themandibular canine region. CAD-CAM fabricated zirconia bar attachmentwas used to retain mandibular overdentures. Patients were randomlydivided into two equal groups where poly-oxy-methylene (POM) clip wasused for Group I and poly-ether-ether-ketone (PEEK) clip for Group II.Retention force was measured at time of overdenture insertion (T0), sixmonths (T6), and twelve months (T12) later.Results: Significant difference was recorded between the two groups ininitial retention forces (T0) where PEEK clip group recorded higherretention forces in comparison to POM clip group (P=0.029). However,insignificant difference was observed at (T6) and (T12). Within groupcomparison of mean retention values at different follow-up periodsrevealed significant difference for both groups.Conclusions: Within parameters of this study, it could be concludedthat both POM and PEEK retentive clips can provide acceptable andcomparable retention forces when used with zirconia bar during 12months period of overdenture use.

🔖

Cite This Article

ALTONBARY, G. Y., EMERA, R. M. K. (2022). Retention force of zirconia bar retained implant overdenture: Clinical comparative study between PEEK and plastic clips. International Dental Research, Cilt: 9 - Sayı: 3, 92–98. https://ajindex.com/articles/539526

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Freitag D. Case Report-A tried and trusted concept in a new formula. Funktionelle und ästhetische Zahntechnik 2014;6:19- 22
  2. Goo C, Tan K. Fabricating CAD/CAM implant-retained mandibular bar overdentures: A clinical and technical overview. Case Rep Dent 2017;2017:id 9373818. (Crossref
  3. Bayer S, Komor N, Kramer A, Albrecht D, Mericske-Stern R, Enkling N: Retention force of plastic clips on implant bars: a randomized controlled trial. Clin. Oral Impl. Res 2012;23:1377- 84. (Crossref
  4. Van Kampen F, Cune M, Van Der Bilt A, Bosman F. Retention and post insertion maintenance of bar- clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin. Oral Impl. Res 2003;14(6):720-6. (Crossref
  5. Bayer S, Gruner M, Keilig L, Hultenschmidt R, Nicolay C, Bourauel C, Utz KH. Investigation of the wear of prefabricated attachments – an in vitro study of retention forces and fitting tolerances. Quintessence Int 2007;38:229-37
  6. Fromentin O, Lassauzay C, Abi Nader S, Feine J, de Albuquerque Junior RF. Testing the retention of attachments for implant overdentures – validation of an original force measurement system. J Oral Rehabil. 2010;37:54-62. (Crossref
  7. Liebermann A, Wimmer T, Schmidlin P R, Scherer H, Löffler P, Roos M, Stawarczyk B. Physicomechanical characterization of polyetheretherketone and current esthetic dental CAD/CAM polymers after aging in different storage media. J. Prosthet. Den 2016;3:321-8. (Crossref
  8. Tekin S, Cangül S, Adıgüzel Ö, Değer Y. Areas for use of PEEK material in dentistry. Int Dent Res 2018;8(2):84-92. (Crossref
  9. Tekin S, Adıgüzel Ö, Cangül S. An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study. Int Dent Res 2018;8(3):144-50. (Crossref
  10. Hammas M, El-Saadawy M, El-Agamy A. Effect of Different Bar Attachment and Clip Materials on Retention Force for Mandibular Implant Supported Overdentures (An Invitro Study). ADJ-for Girls 2018; 5(2):195-204. (Crossref
  11. Hussein M, Elsyad M. A new device measures retention clinically for implant retained overdenture. EDJ 2017;63: 1521-4