Journals / International Dental Research / 2020 / Cilt: 10 - Sayı: 2

Comparison of the resistance to cyclic fatigue of One Curve, One Shape, 2Shape and EdgeFile X3 files in simulated single and S-shaped (double) curvatures

Pages
55–59
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Within the limitations of this study, fracture resistance to cyclic fatigue was the highest for the EdgeFile X3 group followed by the One Curve group and lowest for the 2Shape and One Shape group.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: To evaluate the fracture resistance to cyclic fatigue of One Curve (Micro Mega, Besancon, Cedex, France), One Shape (Micro-Mega), 2Shape (Micro-Mega) and EdgeFile X3 (EdgeEndo, Albuquerque, NM) files in simulated root canals.
📊
Key Findings & Data:The One Curve (25/.06), One Shape (25/.06), 2Shape (25/.06) and EdgeFile X3 (25/.06) files were assessed (n=20 for each test).
💡
Conclusion & Impact:Conclusion: Within the limitations of this study, fracture resistance to cyclic fatigue was the highest for the EdgeFile X3 group followed by the One Curve group and lowest for the 2Shape and One Shape group.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: To evaluate the fracture resistance to cyclic fatigue of One Curve (Micro Mega, Besancon, Cedex, France), One Shape (Micro-Mega), 2Shape (Micro-Mega) and EdgeFile X3 (EdgeEndo, Albuquerque, NM) files in simulated root canals. Methodology: One hundred and sixty nickel-titanium endodontic files were tested in simulated canals with single and s-shaped (double) curvatures. The One Curve (25/.06), One Shape (25/.06), 2Shape (25/.06) and EdgeFile X3 (25/.06) files were assessed (n=20 for each test). All the files were rotated up to fracture occurred. The number of cycles to fracture (NCF) was determined and also, the length of the fractured file part was measured. For statistical analysis, one-way analysis of variance and Tukey HSD tests were used (p 0.05). Conclusion: Within the limitations of this study, fracture resistance to cyclic fatigue was the highest for the EdgeFile X3 group followed by the One Curve group and lowest for the 2Shape and One Shape group.

🔖

Cite This Article

ADIGÜZEL, M., ÖZTEKİN, F. (2022). Comparison of the resistance to cyclic fatigue of One Curve, One Shape, 2Shape and EdgeFile X3 files in simulated single and S-shaped (double) curvatures. International Dental Research, Cilt: 10 - Sayı: 2, 55–59. https://ajindex.com/articles/539512

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Adiguzel M, Capar ID. Comparison of cyclic fatigue resistance of WaveOne and WaveOne Gold Small, Primary, and Large Instruments. J Endod 2017
  2. 43(4):623-7. (Crossref) Adiguzel M, Turgay B. Comparison of the cyclic fatigue resistance of reciproc and reciproc blue nickel-titanium instruments in artificial canals with single and double (s-shaped) curvatures. Eur Endod J 2017
  3. 2(1):32-32 (Crossref) Topcuoglu HS, Topcuoglu G. Cyclic fatigue resistance of Reciproc Blue and Reciproc Files in an s-shaped canal. J Endod 2017
  4. 43(10):1679-82. (Crossref) Gutmann JL, Gao Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review. Int Endod J 2012
  5. 45(2):113-28. (Crossref) Ozyurek T, Gundogar M, Uslu G, Yilmaz K, Staffoli S, Nm G, et al. Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals. Odontology 2018
  6. 106(4):408-13. (Crossref) Gundogar M, Ozyurek T. Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments. J Endod 2017
  7. 43(7):1192-6. (Crossref) Versiani MA, Carvalho KKT, Mazzi-Chaves JF, Sousa-Neto MD. Micro-computed Tomographic Evaluation of the Shaping Ability of XP-endo Shaper, iRaCe, and EdgeFile Systems in Long Oval-shaped Canals. J Endod 2018
  8. 44(3):489-95. (Crossref) Topcuoglu HS, Duzgun S, Akti A, Topcuoglu G. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. Int Endod J 2017
  9. 50(7):713-7. (Crossref) Al-Sudani D, Grande NM, Plotino G, Pompa G, Di Carlo S, Testarelli L, et al. Cyclic fatigue of nickel-titanium rotary instruments in a double (S-shaped) simulated curvature. J Endod 2012
  10. 38(7):987-9. (Crossref) Larsen CM, Watanabe I, Glickman GN, He J. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. J Endod 2009
  11. 35(3):401-3. (Crossref) Elsaka SE, Elnaghy AM, Badr AE. Torsional and bending resistance of WaveOne Gold, Reciproc and Twisted File Adaptive instruments. Int Endod J 2017
  12. 50(11):1077-83.(Crossref) Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod 2012
  13. 38(3):398-401. (Crossref) Topcuoglu HS, Topcuoglu G, Akti A, Duzgun S. In vitro comparison of cyclic fatigue resistance of ProTaper N