Journals / International Dental Research / 2021 / Cilt: 11 - Sayı: Supplement 1

Comparison of the accuracy of three different electronic apex locators used in root canals enlarged in different apical diameters

Pages
12–18
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The accuracy of EALs is not affected by the file size in electronic measurements with file sizes smaller than the apical diameter in teeth with apical diameters up to 0.50 mm.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: This study aimed to evaluate the accuracy of three apex locators in enlarged teeth with different apical diameters using files that are compatible and incompatible with the apical diameters.
📊
Key Findings & Data:The actual canal length was determined with a stereo microscope, and the teeth were divided into three different groups (G25, G40 and G50).
💡
Conclusion & Impact:The accuracy of EALs is not affected by the file size in electronic measurements with file sizes smaller than the apical diameter in teeth with apical diameters up to 0.50 mm.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: This study aimed to evaluate the accuracy of three apex locators in enlarged teeth with different apical diameters using files that are compatible and incompatible with the apical diameters. Methodology: Sixty lower premolars were used in this study. The actual canal length was determined with a stereo microscope, and the teeth were divided into three different groups (G25, G40 and G50). The teeth in G25, G40 and G50 were enlarged in actual canal length with apical diameters of 0.25, 0.40- and 0.50-mm using hand files and Reciproc R25, R40, and R50, respectively. In the electronic measurements, a #15 hand file was used in each group, and #25, #40 and #50 hand files that were compatible with the apical diameters of the teeth in the groups were used. An alginate model was created with enlarged teeth. The electronic working length was determined for each tooth using Root ZX Mini, Raypex 6, and Propex Pixi electronic apex locators (EALs). Results: Electronic measurement results that were shorter by 0.50 mm or longer by 0.05 mm than the actual length were considered unsuccessful; otherwise, they were deemed successful. Analysis of variance was used to evaluate the accuracy of the EALs with different files in the same apical diameter. For the different apical diameters, the chi-square exact test was used to evaluate the accuracy effect of using files that were incompatible with each apical diameter. The level of significance was p > 0.05. In all the groups, the measured lengths were closer to the actual canal length with the use of #25, #40 and #50 hand files that were compatible with the apical diameters. However, there was no significant difference between the measurements with the #15 hand file (p > 0.05). According to the electronic measurement results made with the #15 hand file in teeth with 0.25, 0.40 and 0.50 apical diameters, the use of a file that was incompatible with the apical diameter did not have a significant effect on accuracy (p > 0.05). Conclusion: The use of a file that is compatible with the apical diameter of the tooth in the determination of the working length with measurement of EALs close to the actual canal length. The accuracy of EALs is not affected by the file size in electronic measurements with file sizes smaller than the apical diameter in teeth with apical diameters up to 0.50 mm.

🔖

Cite This Article

ÖZ, H., ADIGÜZEL, Ö., KAYA, S. (2022). Comparison of the accuracy of three different electronic apex locators used in root canals enlarged in different apical diameters. International Dental Research, Cilt: 11 - Sayı: Supplement 1, 12–18. https://ajindex.com/articles/539486

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Heo M-S, Han D-H, An B-M, Huh K-H, Yi W-J, Lee S-S, et al. Effect of ambient light and bit depth of digital radiograph on observer performance in determination of endodontic file positioning. Oral Surg Oral Med Oral Pathol Oral Radiol 2008;105(2):239-244. (Crossref
  2. Bramante CM, Berbert A. A critical evaluation of some methods of determining tooth length. Oral Surg Oral Med Oral Pathol 1974;37(3):463-473. (Crossref
  3. Katz A, Tamse A, Kaufman AY. Tooth length determination: a review. Oral Surg Oral Med Oral Pathol 1991;72(2):238-242. (Crossref
  4. Pratten DH, McDonald N. Comparison of radiographic and electronic working lengths. J Endod 1996;22(4):173-176. (Crossref
  5. Akisue E, Gratieri SD, Barletta FB, Caldeira CL, GrazziotinSoares R, Gavini G. Not all electronic foramen locators are accurate in teeth with enlarged apical foramina: an in vitro comparison of 5 brands. J Endod 2014;40(1):109-112. (Crossref
  6. Aydin U, Karataslioglu E, Aksoy F, Yildirim C. In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters. J Conserv Dent 2015;18(1):66. (Crossref
  7. Sadeghi S, Abolghasemi M. The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study. J Dent Res Dent Clin Dent Prospects 2008;2(1):24
  8. Briseño-Marroquín B, Frajlich S, Goldberg F, Willershausen B. Influence of instrument size on the accuracy of different apex locators: an in vitro study. J Endod 2008;34(6):698-702. (Crossref
  9. Ebrahim A, Yoshioka T, Kobayashi C, Suda H. The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study. Aust Dent J 2006;51(2):153-157. (Crossref
  10. Al‐Bulushi A, Levinkind M, Flanagan M, Ng YL, Gulabivala K. Effect of canal preparation and residual root filling material on root impedance. Int Endod J 2008;41(10):892-904. (Crossref
  11. Altunbaş D, Kuştarcı A, Toyoğlu M. The influence of various irrigants on the accuracy of 2 electronic apex locators in locating simulated root perforations. J Endod 2017;43(3):439- 442. (Crossref
  12. Azabal M, Garcia‐Otero D, De la Macorra J. Accuracy of the Justy II Apex locator in determining working length in simulated horizontal and vertical fractures. Int Endod J 2004;37(3):174- 177. (Crossref
  13. Ebrahim A, Wadachi R, Suda H. An in vitro evaluation of the accuracy of Dentaport ZX apex locator in enlarged root canals. Aust Dent J 2007;52(3):193-197. (Crossref
  14. Herrera M, Ábalos C, Lucena