Journals / International Dental Research / 2021 / Cilt: 11 - Sayı: Supplement 1

Finite elements analysis of stresses formed in core and spongious bone tissue by restored implanted fixed prostheses with Polyetheretherketone (PEEK) and fiber-reinforced composite

Pages
250–258
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Different prosthetic materials had different effects on stress distribution in peri-implant cortical and cancellous bone tissue.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: This study uses the finite element analysis method to compare the effects of different abutments and prosthetic materials on stress distribution in the rehabilitation of maxillary anterior tooth deficiencies with fixed implanted prostheses.
📊
Key Findings & Data:Methodology: In our study, two titanium implant models with a diameter of 4.1 mm and a length of 10 mm were designed for the maxillary central and canine teeth regions. 3D models of the prosthetic restorations were created with PEEK and fiber-reinforced composite and two different abutment materials (titanium and zirconia).
💡
Conclusion & Impact:Conclusion: Different prosthetic materials had different effects on stress distribution in peri-implant cortical and cancellous bone tissue.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: This study uses the finite element analysis method to compare the effects of different abutments and prosthetic materials on stress distribution in the rehabilitation of maxillary anterior tooth deficiencies with fixed implanted prostheses. Methodology: In our study, two titanium implant models with a diameter of 4.1 mm and a length of 10 mm were designed for the maxillary central and canine teeth regions. 3D models of the prosthetic restorations were created with PEEK and fiber-reinforced composite and two different abutment materials (titanium and zirconia). After meshing the materials used with cortical and cancellous bone, Poisson ratio and young module values were loaded into the program. Maxillary central and canine to the palatal surface of the tooth, 2 mm below the incisal edge; a 178 N force was applied in both the vertical and 45° oblique directions, and analysis was performed. The distributions of the highest compression and tensile stress values in peri-implant cortical and cancellous bone were examined, and the results were compared. Results: Material with low elastic modulus caused higher stress accumulation in the cortical and cancellous bone tissue around the implant during oblique force application. In all study groups, the maximum stress values observed in the cancellous and cortical bone during oblique force application were significantly higher than those observed during vertical force application. Thus, different prosthetic materials had different effects on stress distribution in periimplant cortical and cancellous bone tissue, and the highest stress accumulations were in the peri-implant cortical bone. Conclusion: Different prosthetic materials had different effects on stress distribution in peri-implant cortical and cancellous bone tissue.

🔖

Cite This Article

BAŞARAN, E. G., ÇELİK, H., ZENGİNGÜL, A. İ. (2022). Finite elements analysis of stresses formed in core and spongious bone tissue by restored implanted fixed prostheses with Polyetheretherketone (PEEK) and fiber-reinforced composite. International Dental Research, Cilt: 11 - Sayı: Supplement 1, 250–258. https://ajindex.com/articles/539480

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 2001;85(6):585-98. (Crossref
  2. Eraslan O, İnan Ö, Seçilmiş A. The effect of framework design on stress distribution in implant-supported FPDs: A 3-D FEM study. Eur J Dent 2010;4(4):374. (Crossref
  3. Çınar D. İki farklı kemik tipinde kron/implant oranındaki değişikliğin stres oluşumuna etkisinin üç boyutlu sonlu elemanlar stres analizi ile değerlendirilmesi. Protetik Diş Tedavisi, Başkent Üniversitesi, Ankara. 2007
  4. Lin D, Li Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms. Journal of the mechanical behavior of biomedical materials. 2009;2(5):410-32. (Crossref
  5. Van Wijlen P. A modified technique for direct, fibrereinforced, resin-bonded bridges: clinical case reports. Journal (Canadian Dental Association). 2000;66(7):367
  6. İlday NÖ, Zorba YO. Fiberle Güçlendirilmiş Kompozit Inlay Köprü Uygulamaları. Turkiye Klinikleri Journal of Dental Sciences. 2009;15(1):53-8
  7. Meiers JC, Freilich MA. Chairside prefabricated fiberreinforced resin composite fixed partial dentures. Quintessence International. 2001;32(2)
  8. Rose E, Frucht S, Jonas IE. Clinical comparison of a multistranded wire and a direct-bonded polyethylene ribbon--reinforced resin composite used for lingual retention. Quintessence International. 2002;33(8)
  9. Heimer S, Schmidlin PR, Stawarczyk B. Discoloration of PMMA, composite, and PEEK. Clinical oral investigations. 2017;21(4):1191-200. (Crossref
  10. Schmidlin PR, Stawarczyk B, Wieland M, Attin T, Hämmerle CH, Fischer J. Effect of different surface pre-treatments and luting materials on shear bond strength to PEEK. Dental materials. 2010;26(6):553-9. (Crossref
  11. Tekin S, Adıgüzel Ö, Cangül S. An evaluation using micro- CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study. Int Dent Res 2018;8(3):144- 50. (Crossref
  12. Heimer S, Schmidlin PR, Roos M, Stawarczyk B. Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols. The Journal of prosthetic dentistry. 2017;117(3):419-25. (Crossref
  13. Demirci F, Tekin S. Comparison of two adhesive systems of various polyetheretherketone (PEEK) composites on the shear bond strength. Int Dent Res 2021;11(2):54-61. (Crossref
  14. Gao S, Gao S, Xu B, Yu H. Effects of different pH-values on the nano