Journals / ICONARP International Journal Of Architecture And Planning / 2019 / Cilt: 7 - Sayı: 2

A Restoration Criticism of Historical Buildings According to Thermal Comfort Conditions through Ali Gav Madrasah

Pages
385–409
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

And then architecturaldetails should be produced for this.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Thermal comfort studies have been a subject of research since the 1930s.Thermal comfort conditions which are of great importance for humanhealth, are also important for energy.
📊
Key Findings & Data:Todays due to climate changingand a decrease in energy resources, there is a change in indoor thermalcomfort conditions in historic and contemporary buildings.
💡
Conclusion & Impact:And then architecturaldetails should be produced for this.
🔬Design:Research Article
📍Scope:2019 Verileri
⚙️Variables:Domain Parameters

Abstract

Thermal comfort studies have been a subject of research since the 1930s.Thermal comfort conditions which are of great importance for humanhealth, are also important for energy. Todays due to climate changingand a decrease in energy resources, there is a change in indoor thermalcomfort conditions in historic and contemporary buildings. Thermalcomfort conditions are the most important factors affecting the use ofbuildings. So places and spaces where thermal comfort conditions aren’tgood are tried to improve to optimal.The historical buildings constitute the majority of the city's buildingstock in addition to their original and aesthetic architectural qualities,the value for the city. From the planning to the construction process inhistorical buildings it is observed architectural plan schemes are shapedby considering various environmental and climatic factors such as sunand climate thus it can be said energy uses is taken into account. It isimportant to use historical structures and to re-function when they are not available with their original function. With re-use, the new detailsand additional applications that are applied can affect the thermalcomfort properties of the building positively or negatively.This study focuses on the thermal comfort properties that come with therestoration of a historic building. In this context, Ali Gav Madrasah whichis located in castle borders in the historical city center of Konya in Turkeyand restored with a contemporary additional feature that is consideredworthy of being examined in terms of thermal comfort. Thermal analysisof the reconstructed Ali Gav Madrasah, which has undergone restorationthrough integration based on historical documents and excavations andhas a top cover made of modern materials, was carried out in August2018 and January 2019. According to these analyzes, today's thermalconditions are inadequate for all places in Ali Gav Madrasah of thermalcomfort conditions. Comments are made on the connection of thisinsufficient thermal comfort with the restoration/reconstruction. Fromthis point of view, Before the restoration procedures for historicalbuildings, required feasibility studies and necessary solutions aboutbuildings thermal conditions are investigated. And then architecturaldetails should be produced for this.

🔖

Cite This Article

ŞENALP, M., BEYCAN, A. D. O. (2022). A Restoration Criticism of Historical Buildings According to Thermal Comfort Conditions through Ali Gav Madrasah. ICONARP International Journal Of Architecture And Planning, Cilt: 7 - Sayı: 2, 385–409. https://ajindex.com/articles/538280

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. Ahunbay, Z. (2017). Tarihi Çevre Koruma ve Restorasyon: Yem P. Ali Gav Madrasah's Restoration Data, Konya Metropolitan Municipality. Ali Gav Madrasah's Restoration Drawings, Ceray Architecture Restorastion. Altınöz, A. G. B. (2010). Tarihi Dokuda Yeni” nin İnşası. Ege Mimarlık (75), 18-26.
  2. Altıntaş, E. (2008). Termal Konfor Duyarlılık Ölçeğine Göre İlköğretim Dersliklerinin Termal Konfor Açısından Değerlendirilmesi. (Master Thesis), Karadeniz Technical University, Trabzon. American Society of Heating, R. a. A.-C. E., Inc. (2010). Thermal Environmental Conditions for Human Occupancy. In. Asadi, S., Fakhari, M., & Sendi, M. (2016). A study on the thermal behavior of traditional residential buildings: Rasoulian house case study. Journal of Building Engineering, 7, 334- 342. Aynur Yılmaz's Archive Ali Gav Madrasah's old pictures. Balkaş, B. K. (2005). Üniversitelerde Kütüphane BinalarıbKullanım Verimliliğinin Yapı Biyolojisi Açısından İncelenmesi. (Doktora Tezi), İstanbul University, İstanbul.
  3. Coşkun, K. (2006). Çatı Sistemlerİ İle İlgili Performans Gereksinimleri. Çalış, G., Kuru, M., & Alt, B. (2017). Bir Eğitim Binasında Isıl Konfor Koşullarının Analizi: İzmir’de Bir Alan Çalışması. Çalışkan, O. (2012). Türkiye'nin Biyoklimatik Koşullarının Analizi ve Şehirleşmenin Biyoklimatik Koşullara Etkisinin Ankara Ölçeğinde İncelenmesi. (Doktora), Ankara University, Ankara.
  4. Çetin, M., Topay, M., Kaya, L., & Yılmaz, B. (2010). Biyoiklimsel konforun peyzaj planlama sürecindeki etkinliği: Kütahya örneği. Turkish Journal of Forestry, 1(1), 83-95.
  5. Daneshkadeh, S. (2013). The I mpact o f D ouble S kin F acades o n Thermal Performance of Buildings. (Master Thesis), METU, Ankara.
  6. Elwefati, N. A. (2007). Bio-Climatic Architecture in Libya: Case Studies From Three Climatic Regions. (Master Thesis), METU, Ankara.
  7. Georgescu, M. S., Ochinciuc, C. V., Georgescu, E. S., & Colda, I. (2017). Heritage and Climate Changes in Romania: The St. Nicholas Church of Densus, from Degradation to Restoration. Energy Procedia, 133, 76-85.
  8. Güçlü, Y. (2008). Alanya-Samandağ kıyı kuşağında konforlu olma süresi ve deniz turizmi mevsiminin iklim koşullarına göre belirlenmesi. Türk Coğrafya Dergisi(50). Güngör, S., & Polat, A. T. (2012). Bioklimatik konfor ve bioklimatik konfora sahip alanların coğrafi bilgi sistemleri yardımıyla tespitinde kullanılan yöntemler üzerine bir araştırma. KSÜ Mühendislik Bilimleri Dergisi, Özel Sayı, 8-13. ISO EN 7730. (2006). In Ergonomics of the thermal environment- Anal