Journals / Hand and Microsurgery / 2020 / Cilt: 9 - Sayı: 1

Is bio absorbable screw really reliable for midcarpal arthrodesis? A literature review illustrated by a case report

Pages
32–37
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

According to our searchresults and our experience, bioabsorbable screws should be considered with great caution for wrist arthrodesis.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Bio absorbable materials have been used for a long time in human surgery.
📊
Key Findings & Data:Application in various surgical fields as hand,foot, knee and spine surgery were developed.
💡
Conclusion & Impact:According to our searchresults and our experience, bioabsorbable screws should be considered with great caution for wrist arthrodesis.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Bio absorbable materials have been used for a long time in human surgery. Application in various surgical fields as hand,foot, knee and spine surgery were developed. Among the numerous uses in hand surgery, wrist arthrodesis with those materialshas rarely been studied. Should we use bio absorbable screw for midcarpal arthrodesis? We reviewed the literatureabout wrist arthrodesis with absorbable devices and shared our experience with a case of a midcarpal arthrodesis failurewith magnesium and zinc alloy screws. From our review, we found that very few articles about that particular subject werepublished and amongst them very few had good results regarding wrist arthrodesis. Complications were construct failureand led to reintervention. Thus, this subject should be investigated biomechanically and clinically. According to our searchresults and our experience, bioabsorbable screws should be considered with great caution for wrist arthrodesis.

🔖

Cite This Article

SİALA, M., FERRERES, A., OSSES, L. (2022). Is bio absorbable screw really reliable for midcarpal arthrodesis? A literature review illustrated by a case report. Hand and Microsurgery, Cilt: 9 - Sayı: 1, 32–37. https://ajindex.com/articles/533878

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Böstman O, Hirvensalo E, Vainionpää S, Mäkelä A, Vihtonen K, Törmälä P, et al. Ankle fractures treated using biodegradable internal fixation. Clin Orthop 1989;238:195–203
  2. Liu C, Ren Z, Xu Y, Pang S, Zhao X, Zhao Y. Biodegradable magnesium alloys developed as bone repair materials: a review. Scanning 2018;2018:1-15
  3. Waizy H, Seitz J-M, Reifenrath J, Weizbauer A, Bach F-W, Meyer-Lindenberg A, et al. Biodegradable magnesium implants for orthopedic applications. J Mater Sci 2013;48:39–50
  4. Windhagen H, Radtke K, Weizbauer A, Diekmann J, Noll Y, Kreimeyer U, et al. Biodegradable magnesium- based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study. Biomed Eng OnLine 2013;12:62
  5. Bach FD, Carlier RY, Elis JB, Mompoint DM, Feydy A, Judet O, et al. Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up. Radiology 2002;225:541–50
  6. Merle M, Voche PH. [Absorbable osteosynthesis: experimental and clinical approach in surgery of the hand] [Article in French]. Bull Mem Acad R Med Belg 1994;149:329-39; discussion 339-42
  7. Waris E, Ninkovic M, Harpf C, Ninkovic M, Ashammakhi N. Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports. J Hand Surg 2004;29:452–7
  8. Böstman OM, Pihlajamäki HK. Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop 2000;371:216–27
  9. Wendelstein JA, Goger P, Bock P, Schuh R, Doz P, Trnka H-J. Bioabsorbable Fixation Screw for Proximal Interphalangeal Arthrodesis of Lesser Toe Deformities. Foot Ankle Int 2017;38:1020–5
  10. Brkaric M, Baker KC, Israel R, Harding T, Montgomery DM, Herkowitz HN. Early Failure of Bioabsorbable Anterior Cervical Fusion Plates: Case Report and Failure Analysis. J Spinal Disord Tech 2007;20:248–54
  11. Juutilainen T, Pätiälä H. Arthrodesis in rheumatoid arthritis using absorbable screws and rods. Scand J Rheumatol 1995;24:228–33
  12. Voutilainen N, Juutilainen T, Pätiälä H, Rokkanen P. Arthrodesis of the wrist with bioabsorbable fixation in patients with rheumatoid arthritis. J Hand Surg Edinb Scotl 2002;27:563–7
  13. Wichelhaus A, Emmerich J, Mittlmeier T. A Case of Implant Failure in Partial Wrist Fusion Applying Magnesium-Based Headless Bone Screws. Case Rep Orthop 2016;2016:1–5
  14. Ezechieli M, Ettinger M, König C, Weizbauer A, Helmecke P, Schavan R, et al