Journals / Göztepe Tıp Dergisi / 2009 / Cilt: 24 - Sayı: 4

Comparison the results of HRT and OCT in big and small optic disc size

Büyük ve küçük çaplı optik disklerde HRT ve OCT sonuçlarının karşılaştırılması

Pages
153–158
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In relation with the measurements done with HRT II we seperated the patients into two groups: having disc area of ≥ 2.5 mm2 as big disc size and

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: In this study we aimed to asses the effectiveness of two methods(OCT and HRT) , used most frequently in diagnosing and following glaucoma while diagnosing glaucoma of the patients having bigger and smaller disc size .Material and Methods: To an ophthalmologic examination 55 eyes of 55 cases diagnosed as early or suspicient glaucoma were included in the study.
📊
Key Findings & Data:Purpose: In this study we aimed to asses the effectiveness of two methods(OCT and HRT) , used most frequently in diagnosing and following glaucoma while diagnosing glaucoma of the patients having bigger and smaller disc size .Material and Methods: To an ophthalmologic examination 55 eyes of 55 cases diagnosed as early or suspicient glaucoma were included in the study.
💡
Conclusion & Impact:In relation with the measurements done with HRT II we seperated the patients into two groups: having disc area of ≥ 2.5 mm2 as big disc size and
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Purpose: In this study we aimed to asses the effectiveness of two methods(OCT and HRT) , used most frequently in diagnosing and following glaucoma while diagnosing glaucoma of the patients having bigger and smaller disc size .Material and Methods: To an ophthalmologic examination 55 eyes of 55 cases diagnosed as early or suspicient glaucoma were included in the study. In relation with the measurements done with HRT II we seperated the patients into two groups: having disc area of ≥ 2.5 mm2 as big disc size and

Özet

Amaç: Bu çalışmadaki amacımız glokom tanı ve takibinde en sık olarak kullanılan iki yöntemin (OCT ve HRT) büyük ve küçük çaplı disklerde tanı koymadaki etkinliklerini değerlendirmekti. Gereç ve Yöntem: Erken evre glokom tanısı alan veya şüpheli değerlendirilen 55 olgunun 55 gözü çalışma kapsamına alındı. HRT II’de bütün hastaları disk alanlarına ≥ 2.5 mm2 olan büyük disk çaplı ve

🔖

Cite This Article

ATEŞ, O., CİVELEKLER, M. (2022). Comparison the results of HRT and OCT in big and small optic disc size. Göztepe Tıp Dergisi, Cilt: 24 - Sayı: 4, 153–158. https://ajindex.com/articles/526217

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Medeiros FA, Zangwill LM, Bowd C, et al. Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol 2004;122(6):827-837
  2. ZangwilLM, Bowd C, Berry CC, et al. Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph. Arch Ophthalmol 2001;19(7):985-993
  3. Jonas JB, Schmidt AM, Muller-Bergh JA, et al. Human optic nerve fiber count and optic disc size. Invest Ophthalmol Vis Sci 1992;33(6):2012-18
  4. Varma R, Skaf M, Barron E. Retinal nerve fiber layer thickness in normal human eyes. Ophthalmology 1996;103(12):2114-2119
  5. Advanced Glaucoma Intervention Study
  6. Visual field test scoring and reliability. Ophthalmology 1994;101(8):1445-1455
  7. Weinreb RN. Laser scanning tomography to diagnose and monitor glaucoma. Curr Opin Ophthalmol 1993;4(2):3-6
  8. Wollstein G, Garway-Heath DF, Hitchings RA. Identification of early glaucoma cases with the scanning laser ophthalmoscope. Ophthalmology 1998;105(8):1557-1563
  9. Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science 1991;22;254(5035):1178-1181
  10. Zangwill LM, Medeiros FA, Bowd C, et al.Optic nerve imaging: recent advances. In: Krieglstein GK, Weinreb RN, eds. Essentials in Ophthalmology: Glaucoma New York: Springer; 2004:63-91
  11. Medeiros FA, Zangwill LM, Bowd C, et al. Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol 2004;122(6):827-837
  12. Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science 1991;22;254 (5035):1178-1181
  13. Iliev ME, Meyenberg A, Garweg JG. Morphometric assessment of normal, suspect and glaucomatous optic discs with Stratus OCT and HRT II. Eye 2006;20(11):1288-1299
  14. Naithani P, Sihota R, Sony P, et al. Evaluation of optical coherence tomography and heidelberg retinal tomography parameters in detecting early and moderate glaucoma. Ophthalmol Vis Sci 2007;48(7):3138-3145
  15. Tuulonen A, Airaksinen PJ. Optic disc size in exfoliative, primary open angle, and low -tension glaucoma. Arch Ophthalmol 1992;110(2):211-213
  16. Chi T, Ritch R, Stickler D, Pitman B, et al.Racial differences in optic nerve head parameters. Arch Ophthalmol 1989;107(6):836-839
  17. Jonas JB, Fernandez MC,