⚡ TL;DR(Too Long; Didn't Read)

The results show that each property alone (keeping the other propertiesconstant) is not adequate to identify the thermal inertia and thermal performance of a wallelement.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The time lag (TL) and decrement factor (DF) are essential for the heat storage capabilities ofbuilding elements, which strictly depend on the thermophysical properties of the elements.Many investigations are presented in literature arguing to find the influence of eachthermophysical property on TL and DF by keeping the other properties constant.
📊
Key Findings & Data:Therefore, first,132 new concrete wall samples were produced, and their thermophysical properties weretested.
💡
Conclusion & Impact:The results show that each property alone (keeping the other propertiesconstant) is not adequate to identify the thermal inertia and thermal performance of a wallelement.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

The time lag (TL) and decrement factor (DF) are essential for the heat storage capabilities ofbuilding elements, which strictly depend on the thermophysical properties of the elements.Many investigations are presented in literature arguing to find the influence of eachthermophysical property on TL and DF by keeping the other properties constant. This studyaims to investigate the effect of each property on TL and DF, utilizing relationships betweenthe measurement values of the thermophysical properties of wall materials. Therefore, first,132 new concrete wall samples were produced, and their thermophysical properties weretested. Secondly, TL and DF values for each building element are computed from the solutionof the problem by Complex Finite Fourier Transform (CFFT) technique. Finally, amultivariate regression analysis has been performed, and the variations of eachthermophysical property versus TL and DF are presented, and also the findings are comparedwith literature. The results show that each property alone (keeping the other propertiesconstant) is not adequate to identify the thermal inertia and thermal performance of a wallelement. Besides, 87.3 % decrease in thermal diffusivity corresponds to 6.03 h increase in thevalue of TL and 88.8 % decrease in value of DF; respectively, for W1 wall assembly

🔖

Cite This Article

OKTAY, H., YUMRUTAS, R., ARGUNHAN, Z. (2022). An Experimental Investigation of the Effect of Thermophysical Properties on Time Lag and Decrement Factor for Building Elements. Gazi University Journal of Science, Cilt: 33 - Sayı: 2, 492–508. https://ajindex.com/articles/521284

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Moosavi, L., Mahyuddin, N., Ghafar, N.A., Ismail, M.A., “Thermal performance of atria: An overview of natural ventilation effective designs”, Renewable & Sustainable Energy Reviews, 34: 654–670, (2014)
  2. Sun, C., Shu, S., Ding, G., Zhang, X., Hu, X., “Investigation of time lags and decrement factors for different building outside temperatures”, Energy and Buildings, 61: 1–7, (2013)
  3. Mazzeo, D., Oliveti, G., Arcuri, N., “Influence of internal and external boundary conditions on the decrement factor and time lag heat flux of building walls in steady periodic regime”, Applied Energy, 164: 509–531, (2016)
  4. Gasparella, A., Pernigotto, G., Baratieri, M., Baggio, P., “Thermal dynamic transfer properties of the opaque envelope: Analytical and numerical tools for the assessment of the response to summer outdoor conditions”, Energy and Buildings, 43: 2509–2517, (2011)
  5. Ruivo, C. R., Ferreira, P. M., Vaz, D. C., “On the error of calculation of heat gains through walls by methods using constant decrement factor and time lag values”, Energy and Buildings, 60: 252– 261, (2013)
  6. Mavromatidis, L. E., Mankibi, M. E., Michel, P., Santamouris, M., “Numerical estimation of time lags and decrement factors for wall complexes including Multilayer Thermal Insulation, in two different climatic zones”, Applied Energy, 92: 480–491, (2012)
  7. Vijayalakshmi, M. M., Natarajan, E., Shanmugasundaram, V., “Thermal behaviour of building wall elements”, Journal of Applied Sciences, 15: 3128–3133, (2006).[8] Kaşka, Ö., Yumrutaş, R., Arpa, O., “Theoretical and experimental investigation of total equivalent temperature difference (TETD) values for building walls and flat roofs in Turkey”, Applied Energy, 86: 737–747, (2009)
  8. Stephan, E., Cantin, R., Caucheteux, A., Tasca-Guernouti, S., Michel, P., “Experimental assessment of thermal inertia in insulated and non-insulated old limestone buildings”, Building and Environment, 80: 241–248, (2014)
  9. Ulgen, K., “Experimental and theoretical investigation of effects of wall's thermophysical properties on time lag and decrement factor”, Energy and Buildings, 34: 273–278, (2002)
  10. Asan, H.,” Investigation of wall’s optimum insulation position from maximum time lag and minimum decrement factor point of view”, Energy and Buildings, 32: 197–203, (2000)
  11. Asan, H., “Effects of Wall's insulation thickness and position on time lag and decrement factor”, Energy and Buildings, 28: 299-305, (1998)
  12. Ozel, M., “Effect