Journals / European Journal of Technique / 2019 / Cilt: 9 - Sayı: 1

ASSESSMENT OF ENERGY PERFORMANCE BASED ON ENERGY AUDIT OF A HOTEL USING EXERGY APPROACH

Pages
52–65
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Exergetic efficiency for insulatedand uninsulated conditions were found as 27.31% and16.26%, respectively.At the end of the study, some recommendations on effective energymanagement and the applications of a hotel were revealed.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study presents an analytic assessment method of energy consumptionprocesses that was developed to apply to the energy management systems ofhotels.
📊
Key Findings & Data:This method has based directly on an exergetic approach andexamined energy and environmental performances using energy and exergyanalysis with the pre-energy audit.
💡
Conclusion & Impact:Exergetic efficiency for insulatedand uninsulated conditions were found as 27.31% and16.26%, respectively.At the end of the study, some recommendations on effective energymanagement and the applications of a hotel were revealed.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

This study presents an analytic assessment method of energy consumptionprocesses that was developed to apply to the energy management systems ofhotels. This method has based directly on an exergetic approach andexamined energy and environmental performances using energy and exergyanalysis with the pre-energy audit. The energy efficiency performance of thehotel was considered for uninsulated (Case I) and insulated (Case II)conditions. The results of the analysis show that energy consumption lossesare related to not only the structural features of the buildings but also theoperational management of the hotels. Also, the specific energy consumptionof Case II is 43,08% higher than the Case I. Exergetic efficiency for insulatedand uninsulated conditions were found as 27.31% and16.26%, respectively.At the end of the study, some recommendations on effective energymanagement and the applications of a hotel were revealed.

🔖

Cite This Article

SÖĞÜT, M. Z., ÖZ, M. E. U. (2022). ASSESSMENT OF ENERGY PERFORMANCE BASED ON ENERGY AUDIT OF A HOTEL USING EXERGY APPROACH. European Journal of Technique, Cilt: 9 - Sayı: 1, 52–65. https://ajindex.com/articles/512072

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. Karataş M., Babür S., Role of Tourism Sector in the Developing World, KMÜ Journal of Social and Economic Resarches, 15 (25): 15-24, 2013 (TR
  2. WTO, Analysis on Energy Use by European Hotels: Online Survey and Desk Research, Hotel Energy Solutions project publications, Revised version, July 2011, Madrid, Spain,www.unwto.org
  3. Lohani S.P. Energy and exergy analysis of fossil plant and heat pump building heating system at two different dead-state temperatures, Energy Volume 35, Issue 8, August 2010, Pages 3323 -3331
  4. Kondo, K. Energy and exergy utilization efficiencies in the Japanese residential/commercial sectors. Energy Policy 2009, 37, 3475–3483
  5. Gonçalves P., Rodrigues Gaspar A., Gameiro da Silva M., Energy and exergy-based indicators for the energy performance assessment of a hotel building, Energy and Buildings 52 (2012) 181 –188
  6. Xydis G., Koroneos C., Polyzakis A., Energy and exergy analysis of the Greek hotel sector: An application, Energy and Buildings 41 (2009) 402–406
  7. Kilkis B., An Exergy Aware Optimization and Control Algorithm for Sustainable Buildings, International Journal of Green Energy. 01/2004; No. 1:65 -77. DOI:10.1081/GE-120027884
  8. Alujević V. Z., Energy Use and Environmental Impact from Hotels on the Adriatic Coast in Croatia ‐ Current Status and Future Possibilities for HVAC Systems, Doctoral Thesis, Department of Energy Technology Division of Applied Thermodynamics and Refrigeration Royal Institute of Technology Stockholm, Sweden 2006 [9] Hepbasli A. Low exergy (LowEx) heating and cooling systems for sustainable buildings and societies, Renewable and Sustainable Energy Reviews 16 (2012) 73 – 104 [10] Kedici Ö., Energy management, General Directorate of Electrical Power Resources Survey and Development Administration Energy Resources Studies Department, Ankara, Turkey, 1993 [11] Koçak S., Şaşmaz C., Atmaca İ., Examination from the technical and economic aspects of a shopping center for degree-days of different regions according to TS825 isolated, Journal of Installations Engineering Volume 128, 2012, pp. 76-88 [12] ECBCS, Annex 37 2013, Energy conservation in buildings and community systems-low exergy systems for heating and cooling of buildings, Energy Conservation in Buildings and Community Systems (01.12.13)
  9. ECBCS, Annex 49, 2013, Energy conservation in buildings and community systems low exergy systems for high performance buildings and communities, Energy Conservation in Buildings and Communit