Journals / Eurasian Journal of Emergency Medicine / 2020 / Cilt: 19 - Sayı: 1

Measurement of Optic Nerve Sheath Diameter to Detect Increased Intracranial Pressure in Hypertensive Patients

Pages
40–45
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Ultrasonographic ONSDM along with clinical findings and blood pressure measurements may be used for evaluation of response to treatment and deciding on further imaging.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: Our aim was to measure optic nerve sheath diameter (ONSDM) by ultrasonography and to detect whether ONSDM reflected intracranial pressure in hypertensive patients.
📊
Key Findings & Data:Materials and Methods: This observational study was performed prospectively in 149 individuals, 77 (51.7%) of whom were female, including 54 hypertensive-symptomatic patients, 45 hypertensive-asymptomatic patients, and 50 healthy volunteers referred to Emergency Medicine Service of Necmettin Erbakan University, Faculty of Medicine.
💡
Conclusion & Impact:Ultrasonographic ONSDM along with clinical findings and blood pressure measurements may be used for evaluation of response to treatment and deciding on further imaging.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: Our aim was to measure optic nerve sheath diameter (ONSDM) by ultrasonography and to detect whether ONSDM reflected intracranial pressure in hypertensive patients. Materials and Methods: This observational study was performed prospectively in 149 individuals, 77 (51.7%) of whom were female, including 54 hypertensive-symptomatic patients, 45 hypertensive-asymptomatic patients, and 50 healthy volunteers referred to Emergency Medicine Service of Necmettin Erbakan University, Faculty of Medicine. Blood pressure was measured on the right and left upper extremities by the same sphygmomanometer following at least five minutes of rest. ONSDM was recorded. All measurements of hypertensive-symptomatic patients were repeated at 30th minute following antihypertensive therapy. Results: Moderate-to-well statistically significant correlations were determined between initial mean systolic blood pressure and ONSDM (rho=0.629, p=0.001) as well as between initial mean diastolic blood pressure and ONSDM (rho=0.561, p=0.001) in all study groups. Statistically significant differences were determined between the mean pre- and post-treatment systolic and diastolic blood pressures as well as the mean pre- and post-treatment ONSDM values of 40 patients who received antihypertensive therapy (p=0.000, p=0.000, p=0.000, respectively). Conclusion: Ultrasonographic ONSDM reflected increased intracranial pressure in hypertensive patients. The reduction of intracranial pressure was also detected by the same method following antihypertensive treatment. Ultrasonographic ONSDM along with clinical findings and blood pressure measurements may be used for evaluation of response to treatment and deciding on further imaging.

🔖

Cite This Article

CANDER, B., DUMAN, Ç. S., GÜLPEMBE, M., ACAR, T., DİKMETAŞ, C., ERGİN, M., YAVUZ, K., GİRİŞGİN, S., KOÇAK, S. (2022). Measurement of Optic Nerve Sheath Diameter to Detect Increased Intracranial Pressure in Hypertensive Patients. Eurasian Journal of Emergency Medicine, Cilt: 19 - Sayı: 1, 40–45. https://ajindex.com/articles/507984

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (6)

  1. Burt VL, Whelton P, Roccella EJ, Brown C, Cutler JA, Higgins M, et al. Prevalence of hypertension in the US adult population. Results from the Third National Health and Nutrition Examination Survey, 1988-1991. Hypertension. 1995;25:305-13. Organization WH. The world health report 2002: reducing risks, promoting healthy life. In: Organization WH, editor. 2002.
  2. Varon J, Strickman NE. Diagnosis and treatment of hypertensive crises in the elderly patients. J Geriatr Cardiol. 2007;4:50-5.
  3. Zampaglione B, Pascale C, Marchisio M, Cavallo-Perin P. Hypertensive urgencies and emergencies. Prevalence and clinical presentation. Hypertension. 1996;27:144-7. Tintinalli’s Emergency Medicine Seventh Edition: A Comprehensive Study Guide. Tintinalli JE, Stapcyznski JS, Ma OJ, Cline DM, Cydulka RK, Mecker GD, editors. New York: McGraw Medical; 2011.
  4. Geeraerts T, Launey Y, Martin L, Pottecher J, Vigue B, Duranteau J, et al. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med. 2007;33:170411. Trobe JD. Papilledema: the vexing issues. J Neuroophthalmol. 2011;31:175-86.
  5. Roque PJ, Wu TS, Barth L, Drachman D, Khor KN, Lovecchio F, et al. Optic nerve ultrasound for the detection of elevated intracranial pressure in the hypertensive patient. Am J Emerg Med. 2012;30:1357-63.
  6. Rickert K, Sinson G. Intracranial pressure monitoring. Operative Techniques in General Surgery. 2003;5:170-5. 10. Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011;37:1059-68. 11. Emmez ÖH, Egemen E. Kafa içi basınç artışı tedavisinde pratik yaklaşımlar. Yoğun Bakım Dergisi. 2010;9:77-84. 12. Zagardo MT, Cail WS, Kelman SE, Rothman MI. Reversible empty sella in idiopathic intracranial hypertension: an indicator of successful therapy? AJNR Am J Neuroradiol. 1996;17:1953-6. 13. Suzuki H, Takanashi J, Kobayashi K, Nagasawa K, Tashima K, Kohno Y. MR imaging of idiopathic intracranial hypertension. AJNR Am J Neuroradiol. 2001;22:196-9. 14. Aaslid R, Huber P, Nornes H. A transcranial Doppler method in the evaluation of cerebrovascular spasm. Neuroradiology. 1986;28:11-6. 15. Hayreh SS. Pathogenesis of Oedema of the Optic Disc (Papilloedema). A Preliminary Report. Br J Ophthalmol. 1964;48:522-43. 16. Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve