Journals / Erciyes Medical Journal / 2021 / Cilt: 43 - Sayı: 6

The Assessment of Oxidative Stress Biomarkers in Different Serum and Plasma Specimens

Pages
541–547
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The selection of the specimen type to be used in the measurement of IMA, TOS, and TAS is of great importance and now requires standardization.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Appropriate selection of the type of blood specimen tube employed is of great importance to the accurate and reliable measurement of oxidative stress biomarkers.
📊
Key Findings & Data:Materials and Methods: Ischemia-modified albumin, TOS, and TAS levels were assayed in serum and plasma specimens obtained from blood collected from 16 volunteers and placed into serum collection tubes, plain tubes, and anticoagulant tubes containing dipotassium EDTA, trisodium citrate, lithium heparin, and sodium fluoride/disodium EDTA (NaF/Na2EDTA).
💡
Conclusion & Impact:The selection of the specimen type to be used in the measurement of IMA, TOS, and TAS is of great importance and now requires standardization.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: Appropriate selection of the type of blood specimen tube employed is of great importance to the accurate and reliable measurement of oxidative stress biomarkers. This study examined the effect of specimen variety on measurement results using serum and plasma samples obtained from blood tubes with six different contents for measuring ischemia-modified albumin (IMA), total oxidant status (TOS), and total antioxidant status (TAS). Materials and Methods: Ischemia-modified albumin, TOS, and TAS levels were assayed in serum and plasma specimens obtained from blood collected from 16 volunteers and placed into serum collection tubes, plain tubes, and anticoagulant tubes containing dipotassium EDTA, trisodium citrate, lithium heparin, and sodium fluoride/disodium EDTA (NaF/Na2EDTA). IMA was measured using the Bar-Or method, and TOS and TAS were measured using TOS and TAS assay kits, respectively. Total albumin assay was performed using a Beckman Coulter AU5800 autoanalyzer. Results: In all tubes, IMA, IMA/albumin ratio, TOS, TAS, and oxidative stress index values were compared, and all these parameters were found to be statistically significant between six different tubes (p=0.0001). Ischemia-modified albumin and TOS measurements in plasma specimens obtained from tubes containing dipotassium EDTA and NaF/Na2EDTA differed significantly from the results of the other specimens. Conclusion: We conclude that IMA and TOS cannot be measured from blood specimens with dipotassium EDTA and NaF/ Na2EDTA. However, TAS can be determined in all specimen types. The selection of the specimen type to be used in the measurement of IMA, TOS, and TAS is of great importance and now requires standardization.

🔖

Cite This Article

YAMAN, S. Ö., DEMİR, S., KARAHAN, S. C., MENTEŞE, A., ERDEM, M. (2022). The Assessment of Oxidative Stress Biomarkers in Different Serum and Plasma Specimens. Erciyes Medical Journal, Cilt: 43 - Sayı: 6, 541–547. https://ajindex.com/articles/502329

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Vassalle C, Maltinti M, Sabatino L. Targeting oxidative stress for disease prevention and therapy: where do we stand, and where do we go from here. Molecules 2020; 25(11): 2653
  2. Hakkoymaz H, Nazik S, Seyithanoğlu M, Güler Ö, Şahin AR, Cengiz E, et al. The value of ischemia-modified albumin and oxidative stress markers in the diagnosis of acute appendicitis in adults. Am J Emerg Med 2019; 37(11): 2097–101
  3. Mentese A, Güven S, Demir S, Sümer A, Yaman SÖ, Alver A, et al. Circulating parameters of oxidative stress and hypoxia in normal pregnancy and HELLP syndrome. Adv Clin Exp Med 2018; 27(11): 1567–72
  4. Kazaz IO, Mentese A, Demir S, Kerimoglu G, Colak F, Bodur A, et al. Berberine inhibits the ischemia-reperfusion induced testicular injury through decreasing oxidative stress. Am J Emerg Med 2020; 38(1): 33–7
  5. Guven S, Kart C, Guvendag Guven ES, Cetin EC, Menteşe A. Is the measurement of serum ischemia-modified albumin the best test to diagnose ovarian torsion? Gynecol Obstet Invest 2015; 79(4): 269–75
  6. Dilek F, Ozkaya E, Kocyigit A, Yazici M, Kesgin S, Gedik AH, et al. Effect of montelukast monotherapy on oxidative stress parameters and DNA damage in children with asthma. Int Arch Allergy Immunol 2015; 167(2): 119–26
  7. Bukhari SA, Rajoka MI, Ibrahim Z, Jalal F, Rana SM, Nagra SA. Oxidative stress elevated DNA damage and homocysteine level in normal pregnant women in a segment of Pakistani population. Mol Biol Rep 2011; 38(4): 2703–10
  8. Bowen RA, Remaley AT. Interferences from blood collection tube components on clinical chemistry assays. Biochem Med (Zagreb) 2014; 24(1): 31–44
  9. Sulaiman RA, Cornes MP, Whitehead SJ, Othonos N, Ford C, Gama R. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results. J Clin Pathol 2011; 64(11): 1019–20
  10. Bar-Or D, Lau E, Winkler JV. A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report. J Emerg Med 2000; 19(4): 311–5
  11. Erel O. A new automated colorimetric method for measuring total oxidant status. Clin Biochem 2005; 38(12): 1103–11
  12. Erel O. A novel automated direct measurement method for total antioxidant capacity using a new generation, more stable ABTS radical cation. Clin Biochem 2004; 37(4): 277–85
  13. Aycicek A, Erel O, Kocyigit A. Decreased total antioxidant capacity and increased oxidative stress in passive smoker infants and their mothers. Pediatr Int 2005; 47(6): 635–9
  14. Dogan D, Ocal N,