The study also presents the results of extensive validation of the proposed approach in the frequency range up to 3 GHz.
📌 3 Key Takeaways
🎯
Objective & Hypothesis:The paper proposes a semi-analytical approach to improve the analytical method of an enclosure equivalent circuit.
📊
Key Findings & Data:This approach is based on the application of a quasi-static analysis of coplanar striplines in the calculation of the Zap impedance for an enclosure wall with an aperture.
💡
Conclusion & Impact:The study also presents the results of extensive validation of the proposed approach in the frequency range up to 3 GHz.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters
Abstract
The paper proposes a semi-analytical approach to improve the analytical method of an enclosure equivalent circuit. This approach is based on the application of a quasi-static analysis of coplanar striplines in the calculation of the Zap impedance for an enclosure wall with an aperture. Using this approach in conjunction with existing analytical models, the shielding effectiveness can be calculated for an enclosure with an aperture filled with an arbitrary dielectric or magnetic content. The study also presents the results of extensive validation of the proposed approach in the frequency range up to 3 GHz.
🔖
Cite This Article
KOMNATNOV, M. E., GAZIZOV, T. R., IVANOV, A. A., DEMAKOV, A. V. (2022). Semi-analytical Approach for Calculating Shielding Effectiveness of an Enclosure with a Filled Aperture. Electrica, Cilt: 22 - Sayı: 2, 220–225. https://ajindex.com/articles/499905
A. Rusiecki, K. Aniserowicz, A. P. Duffy, and A. Orlandi, “Internal stirring: An approach to approximate evaluation of shielding effectiveness of small slotted enclosures,” IET Sci. Meas. Technol., vol. 10, no. 6, pp. 659–664, Sept. 2016. [CrossRef] 2. F. Li, J. Han, and C. Zhang, “Study of the influence of PCB parameters on the shielding effectiveness of metal cavity with holes,” Proc. IEEE 3rd Int. Tech., Netw., Electron, Autom. Control, Chengdu, China, pp. 383–387, 2019. [CrossRef] 3. D. W. P. Thomas et al., “Model of the electromagnetic field inside a cuboidal enclosure populated with conducting planes or printed circuit boards,” IEEE Trans. Electromagn. Compat., vol. 43, no. 2, pp. 161–169, May 2001. [CrossRef] 4. A. A. Ivanov, M. E. Komnatnov, and T. R. Gazizov, “Analytical model for evaluating shielding effectiveness of an enclosure populated with conducting plates,” IEEE Trans. Electromagn. Compat., vol. 62, no. 5, pp. 2307–2310, Oct. 2020. [CrossRef] 5. T. Konefal, J. F. Dawson, A. C. Marvin, M. P. Robinson, and S. J. Porter, “A fast circuit model description of the shielding effectiveness of a box with imperfect gaskets or apertures covered by thin resistive sheet coatings,” IEEE Trans. Electromagn. Compat., vol. 48, no. 1, pp. 134–144, Feb. 2006. [CrossRef] 6. J. R. Solin, “Formula for the field excited in a cavity sealed by a plate backed with a conductive elastomer,” IEEE Trans. Electromagn. Compat., vol. 58, no. 1, pp. 111–116, Feb. 2006. [CrossRef] 7. R. Araneo, and G. Lovat, “Fast MoM analysis of the shielding effectiveness of rectangular enclosures with apertures, metal plates, and conducting objects,” IEEE Trans. Electromagn. Compat., vol. 51, no. 2, pp. 274–283, May 2009. [CrossRef] 8. B. L. Nie, P. A. Du, Y. T. Yu, and Z. Shi, “Study of the shielding properties of enclosures with apertures at higher frequencies using the transmission line modeling method,” IEEE Trans. Electromagn. Compat., vol. 53, no. 1, pp. 73–81, Feb. 2010. [CrossRef] 9. M. Li, J. Nuebel, J. L. Drewniak, R. E. Dubroff, T. H. Hubing, and T. P. van Doren, “EMI from cavity modes of shielding enclosures-FDTD modeling and measurements,” IEEE Trans. Electromagn. Compat., vol. 42, no. 1, pp. 29–38, Feb. 2000. [CrossRef] 10. S. Celozzi, R. Araneo, and G. Lovat, “Numerical methods for shielding analyses,” in Electromagnetic Shielding. Hoboken, NJ, USA: John Wiley & Sons, Inc., 2008, pp. 87–143. 11. M. P. Robinson et al., “Analytical formulation for the shielding effec