Journals / Electrica / 2022 / Cilt: 22 - Sayı: 2

Improved Performance of Doubly-Fed Induction Generator Wind Turbine During Transient State Considering Supercapacitor Control Strategy

Journal
Electrica
Pages
198–210
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

For a fair comparison between the DFIG supercapacitor and parallel capacitor-based solution, the capacitance value considered was the same to buffer the transient energy.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper proposes a supercapacitor strategy for improving the capability of grid-connected doubly-fed induction generator (DFIG) wind turbines during fault scenarios.
📊
Key Findings & Data:Efforts were made to determine the effective parameters and switching strategies of the supercapacitor by considering different scenarios, in order to improve the transient state of the wind generator.
💡
Conclusion & Impact:For a fair comparison between the DFIG supercapacitor and parallel capacitor-based solution, the capacitance value considered was the same to buffer the transient energy.
🔬Design:Lab & Field Experiment
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

This paper proposes a supercapacitor strategy for improving the capability of grid-connected doubly-fed induction generator (DFIG) wind turbines during fault scenarios. Supercapacitors are one of the important components in sustainable energy systems that are commonly used to store energy. In DFIGs, the supercapacitor is used to compensate for voltage dips and damping oscillations. In this work, a new topology of the supercapacitor system was used to investigate a DFIG wind turbine during transient state. The model system employed was a DFIG connected to the earlier wind turbine technology of fixed speed squirrel cage induction generator. Efforts were made to determine the effective parameters and switching strategies of the supercapacitor by considering different scenarios, in order to improve the transient state of the wind generator. The results obtained under severe grid fault were compared considering the different parameters of the resistance, inductance, and capacitance of the supercapacitor. The DC-link voltage and grid voltage switching strategies of the supercapacitor were investigated. Furthermore, the results of the proposed DFIG supercapacitor were compared with the traditional parallel capacitor scheme for DFIG system. For a fair comparison between the DFIG supercapacitor and parallel capacitor-based solution, the capacitance value considered was the same to buffer the transient energy.

🔖

Cite This Article

OKEDU, K. E. (2022). Improved Performance of Doubly-Fed Induction Generator Wind Turbine During Transient State Considering Supercapacitor Control Strategy. Electrica, Cilt: 22 - Sayı: 2, 198–210. https://ajindex.com/articles/499895

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. W. C. de Carvalho, R. P. Bataglioli, R. A. S. Fernandes, and D. V. Coury, “Fuzzy-based approach for power smoothing of a full-converter wind turbine generator using a supercapacitor energy storage,” Electr. Power Syst. Res., vol. 184, 2020. [CrossRef] 2. A. Hooshyar, M. A. Azzouz, and E. F. El-Saadany, “Three-phase fault direction identification for distribution systems with DFIG-based wind DG,” IEEE Trans. Sustain. Energy, vol. 5, no. 3, pp. 747–756, 2014. [CrossRef] 3. M. M. Kabsha, and Z. H. Rather, “Advanced LVRT control scheme for offshore wind power plant,” IEEE Trans. Power Deliv., vol. 36, no. 6, 3893–3902, 2021. [CrossRef] 4. M. H. Zamani, G. Hossein Riahy, and M. Abedi, “Rotor-speed stability improvement of dual stator winding induction generator-based wind farms by control-windings voltage oriented control,” IEEE Trans. Power Electron., vol. 31, no. 8, pp. 5538–5546, 2016. [CrossRef]. 5. R. Prasad, and N. P. Padhy, “Synergistic frequency regulation control mechanism for DFIG wind turbines with optimal pitch dynamics,” IEEE Trans. Power Syst., vol. 35, no. 4, pp. 3181–3191, 2020. [CrossRef] 6. A. M. A. Haidar, K. M. Muttaqi, and M. T. Hagh, “A coordinated control approach for DC link and Rotor Crowbars to improve fault ride-through of DFIG-based wind turbine,” IEEE Trans. Ind. Appl., vol. 53, no. 4, pp. 4073–4086, 2017. [CrossRef] 7. K. E. Okedu, S. M. Muyeen, R. Takahashi, and J. Tamura, “Wind farms fault ride through using DFIG with new protection scheme,” IEEE Trans. Sustain. Energy, vol. 3, no. 2, pp. 242–254, 2012. [CrossRef] 8. D. Xie, Z. Xu, L. Yang, J. Østergaard, Y. Xue, and K. P. Wong, “A comprehensive LVRT control strategy for DFIG wind turbines with enhanced reactive power support,” in IEEE Trans. Power Syst., vol. 28, no. 3, pp. 3302–3310. [CrossRef] 9. J. Liang, W. Qiao, and R. G. Harley, “Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines,” IEEE Trans. Energy Convers., vol. 25, no. 3, pp. 836–843. [CrossRef] 10. R. Hiremath, and T. Moger, “Comprehensive review on low voltage ride through capability of wind turbine generators, ” Int. Trans. Electr. Energy Syst., vol. 30, no. 10, 2020. [CrossRef] 11. Z. Zou, J. Liao, Y. Lei, Z. Mu, and X. Xiao, “Postfault LVRT performance enhancement of DFIG using a stage-controlled SSFCL-RSDR,” IEEE Trans. Appl. Supercond., vol. 29, no. 2, pp. 1–6. [CrossRef] 12. J. Vidal, G. Abad, J. Arza, and S. Aurtenechea, “Single-phase DC crowbar topolo