The investigation of reuse of organized industrial district wastewater treatment plant effluent for agricultural irrigation purposes

Bir organize sananyi bölgesi atıksu arıtma tesisinden çıkan atıksuların tarımsal amaçlı sulama suyu olarak yeniden kullanılabilirliğinin araştırılması

Journal
Ekoloji
Pages
55–61
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result of study it was determined that the wastewater was reached to 1. class agricultural irrigation purposes quality and reusability was possible.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, reusability of wastewater originated from Organized Industrial District in Bursa city, after treatment in the present treatment plant was investigated to use for agricultural irrigation purposes.
📊
Key Findings & Data:Optimum removal efficiencies were determined at pH=11 at chemical precipitation, with values of 96%, 31% for TSS and COD; 75%, 88% and 90%, color removal efficiencies at 436, 525 and 620 nm wavelength respectively.
💡
Conclusion & Impact:As a result of study it was determined that the wastewater was reached to 1. class agricultural irrigation purposes quality and reusability was possible.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, reusability of wastewater originated from Organized Industrial District in Bursa city, after treatment in the present treatment plant was investigated to use for agricultural irrigation purposes. Treated wastewater coming from present treatment plant was subjected to chemical precipitation and ion exchange to determine removal efficiencies on pollutant parameters over the agricultural irrigation standards. Optimum removal efficiencies were determined at pH=11 at chemical precipitation, with values of 96%, 31% for TSS and COD; 75%, 88% and 90%, color removal efficiencies at 436, 525 and 620 nm wavelength respectively. Average removal efficiency was obtained 90% for conductivity and color parameters by ion exchange method as 71% SO4 -2, 96% Cl-, 95% and 436, 525 and 620 nm respectively at rate of 20 mL H-type resin/ 20 mL OH-type resin. As a result of study it was determined that the wastewater was reached to 1. class agricultural irrigation purposes quality and reusability was possible.

Özet

Bu çalışmada, Bursa ilinde kurulu bulunan bir Organize Sanayi Bölgesinden (OSB) kaynaklanan atıksuların mevcut arıtma tesisinde arıtıldıktan sonra tarımsal amaçlı sulama suyu (TASS) olarak tekrar kullanılabilirliği araştırılmıştır. OSB'de mevcut olan atıksu arıtma tesisinden çıkan arıtılmış atıksu, kimyasal çöktürme ve iyon değişimi yöntemlerine tabi tutularak TASS kullanımı standartlarını aşan kirletici parametreler üzerinde giderim verimleri tespit edilmiştir. Kimyasal çöktürme işleminde optimum giderim verimi pH 11'de sağlanmış olup AKM ve KOI parametrelerinde sırasıyla %96, %31, renk parametresinde 436, 525 ve 620 nm dalga boylarında %75, %88 ve %90 giderim verimleri elde edilmiştir. Iyon değişimi yöntemi ile 20 mL H-Tipi reçine/ 20 mL OH-tipi reçine oranında; %71 SO4 -2, %96 Cl-, %95 iletkenlik ve renk parametresinde 436, 525 ve 620 dalga boylarında ortalama %90 giderim verimleri elde edilmiştir. Çalışma neticesinde, atıksuyun kalitesinin 1. sınıf TASS kalitesine ulaştığı ve tekrar kullanılabilirliğinin mümkün olduğu tespit edilmiştir.

🔖

Cite This Article

ÜSTÜN, G. E., SOLMAZ, S. K. A. (2022). The investigation of reuse of organized industrial district wastewater treatment plant effluent for agricultural irrigation purposes. Ekoloji, Cilt: 16 - Sayı: 62, 55–61. https://ajindex.com/articles/499255

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Abulnour AG, Sorour MH, Talaat HA (2002) Comparative economics for desalting of agricultural drainage water (ADW). Desalination 152, 353-357.
  2. Ahmed S, Chughtai S, Keane MA. (1998) The removal of cadmium and lead from aqueous solution by ion exchange with Na-Y zeolite. Sep. Purif. Technol. 13, 57-64.
  3. Akal Solmaz SK, Üstün GE, Azak HS (2004) An Approach to Wastewater Treatment in Organized Industrial Districts A Pilot-Scale Example from Turkey. International Journal of Environment and Pollution 21, 6, 603-611.
  4. Anonymous (1991) Su Kirliliği Kontrolu Yönetmeliği Teknik Usuller Tebliği, 20748 sayılı Resmi Gazete, Ankara.
  5. Anonymous (2004) Su Kirliliği Kontrol Yönetmeliği, 25687 Sayılı Resmi Gazete, Ankara.
  6. Anonymous (2005)
  7. Bursa Çevre Merkezi Aktüel, Aylık Bülten, 3-4, Ocak 2005,
  8. Bursa. Anonymous (1998) Standard Methods for The Examination of Water and Wastewater. 20th ed., American Public Health Association, Washington, DC. Azak HS, Akal Solmaz, SK, Üstün GE (2002) Evaluation of Organized Industrial Districts in Turkey With Regard to Waste Water Treatament Technologies. In: Kocasoy G (ed.), ISWA 2002 World Environment Congress & Exhibition, Appropriate Environmental and Solid Waste Management and Technologies for Developing Countries, July 8-12 2002,
  9. Istanbul, Vol. III, 1609-1616,
  10. Barlas H (1999) Endüstriyel atıksular için renk parametresi önerisi. In: Türkiye'de Çevre Kirlenmesi Öncelikleri Sempozyumu III, 14-15 Ekim TÜBITAK Gebze Yüksek Teknoloji Enstitüsü, 576-585.
  11. Bixio D, Thoeye C, De Koning J, Joksimovic D, Savic D, Wintgens T, Melin T (2006) Wastewater reclamation and reuse in Europe. Desalination 187, 89-101.
  12. Charerntanyarak L (1999) Heavy metals removal by chemical coagulation and precipitation. Water Sci. Technol. 39, 10/11, 135-138.
  13. Dziubek AM, Kowal AL (1989) High-pH coagulation adsorption: a new technology for water treatment and reuse. Water Sci. Technol. 21, 511-517.
  14. Elmaleh S, Yahi H, Coma J (1996) Suspended solids abatement by pH increase-upgrading of an oxidation pond effluent. Water Research, 30, 10, 2357-2362.
  15. Golob V, Vinder A, Simonic M (2005) Efficiency of the coagulation/flocculation method for the treatment of dye bath effluents. Dyes and Pigments 67, 93-97.
  16. Hochstrat R, Wintgens T, Melin T, Jeffrey P (2005) Wastewater reclamation and reuse in Europe: a model-based potential estimation. Water Supply 5, 1, 67-75.
  17. Kurniawan TA, Chan GYS, Lo WH, Babel S (2006) Physico-chemical treatment techniques for wastewater laden with heavy metals. C