Journals / Eklem Hastalıkları ve Cerrahisi Dergisi (Eski Adı: Artroplasti Artroskopik Cerrahi Derg.) / 2019 / Cilt: 30 - Sayı: 1

Arthroscopy-assisted fixation of Ideberg-type Vb glenoid fracture: A case report

Ideberg tip Vb glenoid kırığının artroskopi yardımlı fiksasyonu: Olgu sunumu

Pages
61–64
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Arthroscopic reduction and fixation of Idebergtype Vb fracture appears to be safe with good radiological and clinical outcomes.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this article, we report a 41-year-old right-handed male patient with Ideberg-type Vb fracture who was treated with arthroscopic reduction and fixation.
📊
Key Findings & Data:The patient was operated, discharged on postoperative day two, and was able to continue his daily activities even at two months postoperatively.
💡
Conclusion & Impact:Arthroscopic reduction and fixation of Idebergtype Vb fracture appears to be safe with good radiological and clinical outcomes.
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this article, we report a 41-year-old right-handed male patient with Ideberg-type Vb fracture who was treated with arthroscopic reduction and fixation. The patient was a laborer who suffered from a high-energy trauma (fall from height). X-ray revealed an intra-articular fracture of the left scapula. Computed tomography with three-dimension reconstruction confirmed the fracture type to be an Ideberg-type Vb glenoid fracture. The patient was operated, discharged on postoperative day two, and was able to continue his daily activities even at two months postoperatively. At six months, the University of California at Los Angeles shoulder score was 33 of 35 and the Disabilities of the Arm, Shoulder, and Hand questionnaire score was 2 of 100. Arthroscopic reduction and fixation of Idebergtype Vb fracture appears to be safe with good radiological and clinical outcomes.

Özet

Bu yazıda, artroskopik redüksiyon ve fiksasyon ile tedavi edilen, Ideberg tip Vb kırığı olan 41 yaşında, sağ elini kullanan bir hasta sunuldu. Hasta yüksek enerjili travmaya (yüksekten düşme) maruz kalmış bir erkek işçi idi. Radyografisinde sol skapulanın eklem içi kırığı olduğu görüldü. Bilgisayarlı tomografinin üç boyutlu rekonstrüksiyonda kırık tipinin Ideberg tipi Vb glenoid kırığı olduğu saptandı. Hasta ameliyat edildi, ameliyat sonrası ikinci günde taburcu edildi ve ameliyattan iki ay sonra bile günlük aktivitelerine devam edebildi. Altı ayda, Los Angeles California Üniversitesi omuz skoru 35 üzerinden 33; Kol, Omuz ve El Sorunları anketi skoru 100 üzerinden 2 idi. Ideberg tip Vb kırığının artroskopik redüksiyon ve fiksasyonu iyi radyolojik ve klinik sonuçlarla güvenilir görünmektedir.

🔖

Cite This Article

ULUSOY, G. R. (2022). Arthroscopy-assisted fixation of Ideberg-type Vb glenoid fracture: A case report. Eklem Hastalıkları ve Cerrahisi Dergisi (Eski Adı: Artroplasti Artroskopik Cerrahi Derg.), Cilt: 30 - Sayı: 1, 61–64. https://ajindex.com/articles/498394

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Tuman JM, Bishop JA, Abrams GD. Arthroscopic Reduction and Internal Fixation of an Inferior Glenoid Fracture With Scapular Extension (Ideberg V). Arthrosc Tech 2015;4:869-72.
  2. Frich LH, Larsen MS. How to deal with a glenoid fracture. EFORT Open Rev 2017;2:151-7. Goss TP. Fractures of the glenoid cavity. J Bone Joint Surg [Am] 1992;74:299-305.
  3. Cole PA, Freeman G, Dubin JR. Scapula fractures. Curr Rev Musculoskelet Med 2013;6:79-87. Adam FF. Surgical treatment of displaced fractures of the glenoid cavity. Int Orthop 2002;26:150-3.
  4. Anavian J, Gauger EM, Schroder LK, Wijdicks CA, Cole PA. Surgical and functional outcomes after operative management of complex and displaced intra-articular glenoid fractures. J Bone Joint Surg [Am] 2012;94:645-53.
  5. Hardegger FH, Simpson LA, Weber BG. The operative treatment of scapular fractures. J Bone Joint Surg [Br] 1984;66:725-31.
  6. Kavanagh BF, Bradway JK, Cofield RH. Open reduction and internal fixation of displaced intra-articular fractures of the glenoid fossa. J Bone Joint Surg [Am] 1993;75:479-84.
  7. Mayo KA, Benirschke SK, Mast JW. Displaced fractures of the glenoid fossa. Results of open reduction and internal fixation. Clin Orthop Relat Res 1998;347:122-30. Cameron SE. Arthroscopic reduction and internal fixation of an anterior glenoid fracture. Arthroscopy 1998;14:743-6.
  8. Bauer T, Abadie O, Hardy P. Arthroscopic treatment of glenoid fractures. Arthroscopy 2006;22: 569.e1-6. Tao MA, Garrigues GE. Arthroscopic-Assisted Fixation of Ideberg Type III Glenoid Fractures. Arthrosc Tech 2015;4:119-25.
  9. Yang HB, Wang D, He XJ. Arthroscopic-assisted reduction and percutaneous cannulated screw fixation for Ideberg type III glenoid fractures: a minimum 2-year follow-up of 18 cases. Am J Sports Med 2011;39:1923-8.
  10. Bonczek SJ, Hutchinson R, Chakravarthy J. An innovative method of fracture reduction in an arthroscopically assisted cannulated screw fixation of an Ideberg type III glenoid fracture. Int J Shoulder Surg 2015;9:56-9. Atik OŞ. Are all case reports worth publishing? Eklem Hastalik Cerrahisi 2016;27:61. Papadonikolakis A. Arthroscopic reduction and fixation of transverse intra-articular glenoid fractures with scapular extension. Arthrosc Tech 2017;6:e879-e85.