Journals / Eastern Journal of Medicine / 2022 / Cilt: 27 - Sayı: 1

Investigation of The Relationship Between Carboxyhemoglobin Level and End-Tidal Carbon Dioxide In Carbon Monoxide Poisoning

Pages
105–111
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The parameters affecting respiratory physiology could not be excluded completely.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Carbon monoxide (CO) poisoning makes up an important part of deaths due to poisoning in the world.
📊
Key Findings & Data:We wanted to investigate the effects of end-tidal carbon dioxide (ETCO2) measurement in expirium on the diagnosis and follow-up of CO poisoning.
💡
Conclusion & Impact:The parameters affecting respiratory physiology could not be excluded completely.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Carbon monoxide (CO) poisoning makes up an important part of deaths due to poisoning in the world. It may be hard to diagnose CO poisoning if it is not suspected because the clinical features are non-specific. We wanted to investigate the effects of end-tidal carbon dioxide (ETCO2) measurement in expirium on the diagnosis and follow-up of CO poisoning. After the patients were diagnosed as having CO poisoning by taking arterial blood gas from patients who were suspected of having CO poisoning, ETCO₂ was measured using the sidestream method. The data were analyzed using the SPSS (IBM SPSS for Windows, ver.23) statistical package program. One hundred fourty six146 patients, 106 with CO poisoning and 40 control cases, were included in the study. After the demographic data were evaluated, the relationship between ETCO2 and carboxyhemoglobin (COHb) was analyzed. No statistically significant difference was found. To the best of our knowledge, this is the first study to look for a relationship between ETCO2 and COHb. More studies are required to investigate the relationship between ETCO2 and COHb. The study was conducted in a single centre with a few patients. Only the sidestream method was used in the measurement of ETCO2. The parameters affecting respiratory physiology could not be excluded completely.

🔖

Cite This Article

AKTAŞ, R. S., DURUKAN, P. (2022). Investigation of The Relationship Between Carboxyhemoglobin Level and End-Tidal Carbon Dioxide In Carbon Monoxide Poisoning. Eastern Journal of Medicine, Cilt: 27 - Sayı: 1, 105–111. https://ajindex.com/articles/494516

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Mukhopadhyay S, Hirsch A, Etienne S, Melnikova N, Wu J, Sircar K, Orr M. Surveillance of carbon monoxide-related incidents—Implications for prevention of related illnesses and injuries, 2005–2014. The American journal of emergency medicine. 2018
  2. Choi IS. Carbon monoxide poisoning: systemic manifestations and complications. Journal of Korean medical science 2001; 16: 253-261
  3. Kao LW, Nanagas KA. Carbon monoxide poisoning. Emerg Med Clin North Am 2004; 22: 985-1018
  4. Lindell K. W., Ramona O. H., Karen J. C., et.al. Hyperbaric Oxygen for Acute Carbon Monoxide Poisoning. New England Journal Of Medicine 2002; 347: 1057-1067
  5. Harper A, Croft-Baker J. Carbon monoxide poisoning: undetected by both patients and their doctors. Age Ageing, 2004; 33, 105-109
  6. Kandiş H, Katırcı Y, Karapolat B. Karbonmonoksit zehirlenmesi. Düzce Üniversitesi Tıp Fakültesi Dergisi 2009; 11: 54-60
  7. Hampson NB, Piantadosi CA, Thom SR, Weaver LK. Practice recommendations in the diagnosis, management, and prevention of carbon monoxide poisoning. American journal of respiratory and critical care medicine 2012; 186: 1095-1101
  8. Paiva EF, Paxton JH, O'Neil BJ. The use of end-tidal carbon dioxide (ETCO 2) measurement to guide management of cardiac arrest: A systematic review. Resuscitation 2018; 123: 1-7
  9. Sanders AB. Capnometry in emergency medicine. Annals of emergency medicine, 1989; 18, 1287-1290
  10. Block FE, McDonald JS. Sidestream versus mainstream carbon dioxide analyzers. Journal of clinical monitoring 1992; 8: 139-141
  11. Gravenstein JS, de Vries A, Beneken JE. Sampling intervals for clinical monitoring of variables during anesthesia. Journal of clinical monitoring 1989; 5: 17-21
  12. Aminiahidashti H, Shafiee S, Kiasari AZ, Sazgar M. Applications of End-Tidal Carbon Dioxide (ETCO2) Monitoring in Emergency Department; a Narrative Review. Emergency 2018; 6
  13. Kronick SL, Kurz MC, Lin S, Edelson DP, Berg RA, Billi JE, Cabanas JG, Cone DC, Diercks DB, Foster J. Part 4: systems of care and continuous quality improvement: 2015 American Heart Association guidelines update for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2015; 132: 397-413
  14. M Güven. Karbonmonoksit Zehirlenmesi: Görünmez kaza. Yoğun bakım dergisi 2005; 4: 221-226
  15. Kim YJ, Sohn CH, Seo DW, Oh BJ, Lim KS, Kim WY. Clinical predictors of acute brain injury in carbon monoxide poisoning patients with altered mental status at admission to emergency department. Acade